{"title":"CAD/CAM 数字化复制模式下不同材料全瓷冠的精确度分析。","authors":"Haoyang Wang, Wenli Qu, Ting Wang, Xuan Wu, Hao Sun","doi":"10.1186/s12903-025-05892-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The study aimed to evaluate the three-dimensional accuracy of computer-aided design and computer-aided manufacturing (CAD/CAM) in fabricating all-ceramic crowns using various cuttable materials, assessed through reverse engineering.</p><p><strong>Methods: </strong>The original resin tooth morphology of the left maxillary mesial incisor and left maxillary first molar from a standard resin tooth model, along with the two corresponding prepared teeth, were scanned and imported into exocad software. The digitally reproduced crown morphology was utilized to fabricate crowns from cut porcelain-reinforced resin ceramic (Uh group, Upcera Hyramic), lithium disilicate glass-ceramic (e.max group, IPS e.max Cad), and zirconia ceramic (Ue group, Upcera Explore). All specimens were subsequently rescanned, and the root mean square (RMS) values were calculated after overlaying with the original crown CAD data using the 3D analysis software Geomagic Studio 2013 to compare the dimensional accuracy.</p><p><strong>Results: </strong>Among the mesial incisor and first molar specimens, the e.max group demonstrated the highest dimensional accuracy of the all-ceramic crowns, followed by the Ue group, while the Uh group exhibited the lowest accuracy. The differences in dimensional accuracy among the three groups were statistically significant (P < 0.05).</p><p><strong>Conclusion: </strong>The digital replication technique effectively restored the original crown morphology with a high degree of accuracy. For the same CAM pattern, the dimensional accuracy of all-ceramic crowns varied depending on the CAD/CAM porcelain material, with lithium disilicate glass-ceramic showing the superior results.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"491"},"PeriodicalIF":2.6000,"publicationDate":"2025-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11971805/pdf/","citationCount":"0","resultStr":"{\"title\":\"Accuracy analysis of all-ceramic crowns with different materials in CAD/CAM digital replication mode.\",\"authors\":\"Haoyang Wang, Wenli Qu, Ting Wang, Xuan Wu, Hao Sun\",\"doi\":\"10.1186/s12903-025-05892-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The study aimed to evaluate the three-dimensional accuracy of computer-aided design and computer-aided manufacturing (CAD/CAM) in fabricating all-ceramic crowns using various cuttable materials, assessed through reverse engineering.</p><p><strong>Methods: </strong>The original resin tooth morphology of the left maxillary mesial incisor and left maxillary first molar from a standard resin tooth model, along with the two corresponding prepared teeth, were scanned and imported into exocad software. The digitally reproduced crown morphology was utilized to fabricate crowns from cut porcelain-reinforced resin ceramic (Uh group, Upcera Hyramic), lithium disilicate glass-ceramic (e.max group, IPS e.max Cad), and zirconia ceramic (Ue group, Upcera Explore). All specimens were subsequently rescanned, and the root mean square (RMS) values were calculated after overlaying with the original crown CAD data using the 3D analysis software Geomagic Studio 2013 to compare the dimensional accuracy.</p><p><strong>Results: </strong>Among the mesial incisor and first molar specimens, the e.max group demonstrated the highest dimensional accuracy of the all-ceramic crowns, followed by the Ue group, while the Uh group exhibited the lowest accuracy. The differences in dimensional accuracy among the three groups were statistically significant (P < 0.05).</p><p><strong>Conclusion: </strong>The digital replication technique effectively restored the original crown morphology with a high degree of accuracy. For the same CAM pattern, the dimensional accuracy of all-ceramic crowns varied depending on the CAD/CAM porcelain material, with lithium disilicate glass-ceramic showing the superior results.</p>\",\"PeriodicalId\":9072,\"journal\":{\"name\":\"BMC Oral Health\",\"volume\":\"25 1\",\"pages\":\"491\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11971805/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Oral Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12903-025-05892-9\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-05892-9","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy analysis of all-ceramic crowns with different materials in CAD/CAM digital replication mode.

Background: The study aimed to evaluate the three-dimensional accuracy of computer-aided design and computer-aided manufacturing (CAD/CAM) in fabricating all-ceramic crowns using various cuttable materials, assessed through reverse engineering.

Methods: The original resin tooth morphology of the left maxillary mesial incisor and left maxillary first molar from a standard resin tooth model, along with the two corresponding prepared teeth, were scanned and imported into exocad software. The digitally reproduced crown morphology was utilized to fabricate crowns from cut porcelain-reinforced resin ceramic (Uh group, Upcera Hyramic), lithium disilicate glass-ceramic (e.max group, IPS e.max Cad), and zirconia ceramic (Ue group, Upcera Explore). All specimens were subsequently rescanned, and the root mean square (RMS) values were calculated after overlaying with the original crown CAD data using the 3D analysis software Geomagic Studio 2013 to compare the dimensional accuracy.

Results: Among the mesial incisor and first molar specimens, the e.max group demonstrated the highest dimensional accuracy of the all-ceramic crowns, followed by the Ue group, while the Uh group exhibited the lowest accuracy. The differences in dimensional accuracy among the three groups were statistically significant (P < 0.05).

Conclusion: The digital replication technique effectively restored the original crown morphology with a high degree of accuracy. For the same CAM pattern, the dimensional accuracy of all-ceramic crowns varied depending on the CAD/CAM porcelain material, with lithium disilicate glass-ceramic showing the superior results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信