校准电阻抗断层扫描中的通气/灌注匹配:基于动脉血压的新方法。

IF 3.2 3区 医学 Q2 PHYSIOLOGY
Frontiers in Physiology Pub Date : 2025-03-13 eCollection Date: 2025-01-01 DOI:10.3389/fphys.2025.1545652
Tixin Han, Yangchun Qin, Zhibo Zhao, Bin Yang, Xuechao Liu, Lei Li, Ziyu Wei, Liping Wei, Yifan Liu, Feng Fu
{"title":"校准电阻抗断层扫描中的通气/灌注匹配:基于动脉血压的新方法。","authors":"Tixin Han, Yangchun Qin, Zhibo Zhao, Bin Yang, Xuechao Liu, Lei Li, Ziyu Wei, Liping Wei, Yifan Liu, Feng Fu","doi":"10.3389/fphys.2025.1545652","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Electrical impedance tomography (EIT) enables non-invasive, continuous, bedside evaluation of ventilation/perfusion (V/Q) match. To avoid the presence of invasive monitoring for cardiac output in relative V/Q ratio calculation, we proposed a novel calibration method based on arterial blood pressure to optimize EIT V/Q match assessments.</p><p><strong>Methods: </strong>We involved 12 mechanically ventilated piglets in three experimental phases: baseline, pulmonary embolism, and atelectasis. After a thorough measurement of EIT signals, arterial blood pressure, cardiac output, and additional physiological parameters, EIT V/Q match was evaluated using existing area limited method (ALM), cardiac output calibrated method (COCM), and our proposed novel blood pressure calibrated method (BPCM). Finally, V<sub>D</sub>/V<sub>T</sub> and P/F ratio were calculated and correlated with V/Q match indicators derived from COCM and BPCM.</p><p><strong>Results: </strong>Arterial blood pressure waveform integration demonstrated strong correlation with cardiac output (<i>R</i> <sup>2</sup> = 0.80, p < 0.001), validating its utility for cardiac output estimation and V/Q match calibration. Both COCM and BPCM provided enhanced V/Q match region segmentation compared to ALM, yielding comprehensive diagnostic information with statistically significant differences across all three states (p < 0.05). COCM demonstrates a slightly higher correlation compared to BPCM (r = -0.63 vs. -0.52) between low ventilation index (LVI) and V<sub>D</sub>/V<sub>T</sub>, while BPCM demonstrates a slightly higher correlation compared to COCM (r = 0.49 vs. 0.44) between low perfusion index (LQI) and P/F ratio.</p><p><strong>Conclusion: </strong>This study described a novel calibration method for calculating corrected EIT-based V/Q match that utilized arterial blood pressure. Our method exhibited comparable capability in distinguishing V/Q mismatch areas compared to conventional cardiac output-based calibration techniques. With clinical data to establish a linear regression model, our method will ultimately enable us to calculate calibrated EIT V/Q match without cardiac output monitoring.</p>","PeriodicalId":12477,"journal":{"name":"Frontiers in Physiology","volume":"16 ","pages":"1545652"},"PeriodicalIF":3.2000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11966062/pdf/","citationCount":"0","resultStr":"{\"title\":\"Calibration of ventilation/perfusion match in electrical impedance tomography: a novel method based on arterial blood pressure.\",\"authors\":\"Tixin Han, Yangchun Qin, Zhibo Zhao, Bin Yang, Xuechao Liu, Lei Li, Ziyu Wei, Liping Wei, Yifan Liu, Feng Fu\",\"doi\":\"10.3389/fphys.2025.1545652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Electrical impedance tomography (EIT) enables non-invasive, continuous, bedside evaluation of ventilation/perfusion (V/Q) match. To avoid the presence of invasive monitoring for cardiac output in relative V/Q ratio calculation, we proposed a novel calibration method based on arterial blood pressure to optimize EIT V/Q match assessments.</p><p><strong>Methods: </strong>We involved 12 mechanically ventilated piglets in three experimental phases: baseline, pulmonary embolism, and atelectasis. After a thorough measurement of EIT signals, arterial blood pressure, cardiac output, and additional physiological parameters, EIT V/Q match was evaluated using existing area limited method (ALM), cardiac output calibrated method (COCM), and our proposed novel blood pressure calibrated method (BPCM). Finally, V<sub>D</sub>/V<sub>T</sub> and P/F ratio were calculated and correlated with V/Q match indicators derived from COCM and BPCM.</p><p><strong>Results: </strong>Arterial blood pressure waveform integration demonstrated strong correlation with cardiac output (<i>R</i> <sup>2</sup> = 0.80, p < 0.001), validating its utility for cardiac output estimation and V/Q match calibration. Both COCM and BPCM provided enhanced V/Q match region segmentation compared to ALM, yielding comprehensive diagnostic information with statistically significant differences across all three states (p < 0.05). COCM demonstrates a slightly higher correlation compared to BPCM (r = -0.63 vs. -0.52) between low ventilation index (LVI) and V<sub>D</sub>/V<sub>T</sub>, while BPCM demonstrates a slightly higher correlation compared to COCM (r = 0.49 vs. 0.44) between low perfusion index (LQI) and P/F ratio.</p><p><strong>Conclusion: </strong>This study described a novel calibration method for calculating corrected EIT-based V/Q match that utilized arterial blood pressure. Our method exhibited comparable capability in distinguishing V/Q mismatch areas compared to conventional cardiac output-based calibration techniques. With clinical data to establish a linear regression model, our method will ultimately enable us to calculate calibrated EIT V/Q match without cardiac output monitoring.</p>\",\"PeriodicalId\":12477,\"journal\":{\"name\":\"Frontiers in Physiology\",\"volume\":\"16 \",\"pages\":\"1545652\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11966062/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in Physiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3389/fphys.2025.1545652\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"PHYSIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3389/fphys.2025.1545652","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Calibration of ventilation/perfusion match in electrical impedance tomography: a novel method based on arterial blood pressure.

Introduction: Electrical impedance tomography (EIT) enables non-invasive, continuous, bedside evaluation of ventilation/perfusion (V/Q) match. To avoid the presence of invasive monitoring for cardiac output in relative V/Q ratio calculation, we proposed a novel calibration method based on arterial blood pressure to optimize EIT V/Q match assessments.

Methods: We involved 12 mechanically ventilated piglets in three experimental phases: baseline, pulmonary embolism, and atelectasis. After a thorough measurement of EIT signals, arterial blood pressure, cardiac output, and additional physiological parameters, EIT V/Q match was evaluated using existing area limited method (ALM), cardiac output calibrated method (COCM), and our proposed novel blood pressure calibrated method (BPCM). Finally, VD/VT and P/F ratio were calculated and correlated with V/Q match indicators derived from COCM and BPCM.

Results: Arterial blood pressure waveform integration demonstrated strong correlation with cardiac output (R 2 = 0.80, p < 0.001), validating its utility for cardiac output estimation and V/Q match calibration. Both COCM and BPCM provided enhanced V/Q match region segmentation compared to ALM, yielding comprehensive diagnostic information with statistically significant differences across all three states (p < 0.05). COCM demonstrates a slightly higher correlation compared to BPCM (r = -0.63 vs. -0.52) between low ventilation index (LVI) and VD/VT, while BPCM demonstrates a slightly higher correlation compared to COCM (r = 0.49 vs. 0.44) between low perfusion index (LQI) and P/F ratio.

Conclusion: This study described a novel calibration method for calculating corrected EIT-based V/Q match that utilized arterial blood pressure. Our method exhibited comparable capability in distinguishing V/Q mismatch areas compared to conventional cardiac output-based calibration techniques. With clinical data to establish a linear regression model, our method will ultimately enable us to calculate calibrated EIT V/Q match without cardiac output monitoring.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.50
自引率
5.00%
发文量
2608
审稿时长
14 weeks
期刊介绍: Frontiers in Physiology is a leading journal in its field, publishing rigorously peer-reviewed research on the physiology of living systems, from the subcellular and molecular domains to the intact organism, and its interaction with the environment. Field Chief Editor George E. Billman at the Ohio State University Columbus is supported by an outstanding Editorial Board of international researchers. This multidisciplinary open-access journal is at the forefront of disseminating and communicating scientific knowledge and impactful discoveries to researchers, academics, clinicians and the public worldwide.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信