{"title":"减少周转时间的自动尿液培养系统:一个前瞻性的现实世界评估","authors":"Lorena Porte ,&nbsp;María Jesús Alfaro ,&nbsp;Carmen Varela ,&nbsp;Jorge Reyes ,&nbsp;Thomas Weitzel","doi":"10.1016/j.diagmicrobio.2025.116826","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Urinary tract infections are among the most common bacterial illnesses in clinical practice. Urine culture is the diagnostic reference standard for these infections, representing a major proportion of the workload of microbiological laboratories. Conventional urine cultures require 18-24 h of incubation and are negative in about 80.0 %. Uroquattro-HB&amp;L® [Alifax] is an automated urine culture system providing results in 5 h.</div></div><div><h3>Objectives</h3><div>To evaluate the diagnostic performance of this rapid system compared to conventional culture and test its applicability for rapid identification and susceptibility testing in a real-world setting.</div></div><div><h3>Methods</h3><div>A total of 1,062 routine urine samples were included and tested in parallel by Uroquattro-HB&amp;L rapid culture and by conventional culture. Uroquattro-HB&amp;L performance was analyzed in comparison to conventional culture and a composite reference standard. Microorganisms from rapid culture were identified by MALDI-TOF technique. In a subset of 58 Uroquattro-HB&amp;L-positive samples, a rapid susceptibility testing protocol was applied using the VITEK 2 XL system.</div></div><div><h3>Results</h3><div>Compared to conventional culture, Uroquattro-HB&amp;L showed a sensitivity of 87.3 %, specificity of 91.1 %, accuracy of 90.5 %, and positive and negative predictive values of 64.9 % and 97.4 %, respectively. Using the composite reference standard, the sensitivity and specificity were 91.3 % and 100 %, respectively. Agreement between the identification results was 92.3 %. Rapid antimicrobial susceptibility testing showed &gt;90.0 % concordance with conventional AST.</div></div><div><h3>Conclusions</h3><div>Uroquattro-HB&amp;L accurately identified culture-negative urine samples and permitted the identification of positive samples within 4-5 h. The system was also used to obtain rapid susceptibility testing results; however, this application requires further evaluation.</div></div>","PeriodicalId":11329,"journal":{"name":"Diagnostic microbiology and infectious disease","volume":"112 3","pages":"Article 116826"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automated urine culture system with reduced turnaround time: A prospective real-world evaluation\",\"authors\":\"Lorena Porte ,&nbsp;María Jesús Alfaro ,&nbsp;Carmen Varela ,&nbsp;Jorge Reyes ,&nbsp;Thomas Weitzel\",\"doi\":\"10.1016/j.diagmicrobio.2025.116826\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Urinary tract infections are among the most common bacterial illnesses in clinical practice. Urine culture is the diagnostic reference standard for these infections, representing a major proportion of the workload of microbiological laboratories. Conventional urine cultures require 18-24 h of incubation and are negative in about 80.0 %. Uroquattro-HB&amp;L® [Alifax] is an automated urine culture system providing results in 5 h.</div></div><div><h3>Objectives</h3><div>To evaluate the diagnostic performance of this rapid system compared to conventional culture and test its applicability for rapid identification and susceptibility testing in a real-world setting.</div></div><div><h3>Methods</h3><div>A total of 1,062 routine urine samples were included and tested in parallel by Uroquattro-HB&amp;L rapid culture and by conventional culture. Uroquattro-HB&amp;L performance was analyzed in comparison to conventional culture and a composite reference standard. Microorganisms from rapid culture were identified by MALDI-TOF technique. In a subset of 58 Uroquattro-HB&amp;L-positive samples, a rapid susceptibility testing protocol was applied using the VITEK 2 XL system.</div></div><div><h3>Results</h3><div>Compared to conventional culture, Uroquattro-HB&amp;L showed a sensitivity of 87.3 %, specificity of 91.1 %, accuracy of 90.5 %, and positive and negative predictive values of 64.9 % and 97.4 %, respectively. Using the composite reference standard, the sensitivity and specificity were 91.3 % and 100 %, respectively. Agreement between the identification results was 92.3 %. Rapid antimicrobial susceptibility testing showed &gt;90.0 % concordance with conventional AST.</div></div><div><h3>Conclusions</h3><div>Uroquattro-HB&amp;L accurately identified culture-negative urine samples and permitted the identification of positive samples within 4-5 h. The system was also used to obtain rapid susceptibility testing results; however, this application requires further evaluation.</div></div>\",\"PeriodicalId\":11329,\"journal\":{\"name\":\"Diagnostic microbiology and infectious disease\",\"volume\":\"112 3\",\"pages\":\"Article 116826\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic microbiology and infectious disease\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S073288932500149X\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INFECTIOUS DISEASES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic microbiology and infectious disease","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S073288932500149X","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

摘要

背景:泌尿道感染是临床上最常见的细菌性疾病之一。尿培养是这些感染的诊断参考标准,占微生物实验室工作量的很大一部分。常规尿液培养需要18-24小时的孵育,80%为阴性。Uroquattro-HB&;L®[Alifax]是一种自动尿液培养系统,可提供5 h的结果。目的评估该快速系统与传统培养相比的诊断性能,并测试其在现实环境中快速识别和药敏试验的适用性。方法收集1062例尿样,采用uroquatro - hb&;L快速培养与常规培养并行检测。将uroquatro - hb&;L与常规培养物和复合参比标准物进行性能分析。用MALDI-TOF技术对快速培养的微生物进行鉴定。在58份uroquatro - hb&; l阳性样本中,使用VITEK 2 XL系统应用快速药敏试验方案。结果与常规培养相比,uroquatro - hb&;L的敏感性为87.3%,特异性为91.1%,准确性为90.5%,阳性预测值为64.9%,阴性预测值为97.4%。采用该标准品,灵敏度为91.3%,特异度为100%。鉴定结果的符合率为92.3%。结论suroquatro - hb&;L能准确识别培养阴性尿样,并能在4 ~ 5 h内识别阳性尿样,可获得快速药敏试验结果;然而,这个应用程序需要进一步的评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automated urine culture system with reduced turnaround time: A prospective real-world evaluation

Background

Urinary tract infections are among the most common bacterial illnesses in clinical practice. Urine culture is the diagnostic reference standard for these infections, representing a major proportion of the workload of microbiological laboratories. Conventional urine cultures require 18-24 h of incubation and are negative in about 80.0 %. Uroquattro-HB&L® [Alifax] is an automated urine culture system providing results in 5 h.

Objectives

To evaluate the diagnostic performance of this rapid system compared to conventional culture and test its applicability for rapid identification and susceptibility testing in a real-world setting.

Methods

A total of 1,062 routine urine samples were included and tested in parallel by Uroquattro-HB&L rapid culture and by conventional culture. Uroquattro-HB&L performance was analyzed in comparison to conventional culture and a composite reference standard. Microorganisms from rapid culture were identified by MALDI-TOF technique. In a subset of 58 Uroquattro-HB&L-positive samples, a rapid susceptibility testing protocol was applied using the VITEK 2 XL system.

Results

Compared to conventional culture, Uroquattro-HB&L showed a sensitivity of 87.3 %, specificity of 91.1 %, accuracy of 90.5 %, and positive and negative predictive values of 64.9 % and 97.4 %, respectively. Using the composite reference standard, the sensitivity and specificity were 91.3 % and 100 %, respectively. Agreement between the identification results was 92.3 %. Rapid antimicrobial susceptibility testing showed >90.0 % concordance with conventional AST.

Conclusions

Uroquattro-HB&L accurately identified culture-negative urine samples and permitted the identification of positive samples within 4-5 h. The system was also used to obtain rapid susceptibility testing results; however, this application requires further evaluation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.30
自引率
3.40%
发文量
149
审稿时长
56 days
期刊介绍: Diagnostic Microbiology and Infectious Disease keeps you informed of the latest developments in clinical microbiology and the diagnosis and treatment of infectious diseases. Packed with rigorously peer-reviewed articles and studies in bacteriology, immunology, immunoserology, infectious diseases, mycology, parasitology, and virology, the journal examines new procedures, unusual cases, controversial issues, and important new literature. Diagnostic Microbiology and Infectious Disease distinguished independent editorial board, consisting of experts from many medical specialties, ensures you extensive and authoritative coverage.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信