自测验光、自动验光和主观验光的比较。

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2025-03-28 eCollection Date: 2025-01-01 DOI:10.2147/OPTH.S510850
Abraão Ferreira de Sousa Neto Kós, Bernardo Kaplan Moscovici, Cesar Vilar, Mario Augusto Pereira Dias Chaves, Maíra Gomes Barbosa Da Silva, Maurício Agne Neuwald, André Lins De Medeiros, Jonathan Clive Lake, Antonio Francisco Pimenta Motta, Patrick Frensel de Moraes Tzelikis, Pedro Carlos Carricondo, Larissa Gouvea, Walton Nosé, Wilson Takashi Hida
{"title":"自测验光、自动验光和主观验光的比较。","authors":"Abraão Ferreira de Sousa Neto Kós, Bernardo Kaplan Moscovici, Cesar Vilar, Mario Augusto Pereira Dias Chaves, Maíra Gomes Barbosa Da Silva, Maurício Agne Neuwald, André Lins De Medeiros, Jonathan Clive Lake, Antonio Francisco Pimenta Motta, Patrick Frensel de Moraes Tzelikis, Pedro Carlos Carricondo, Larissa Gouvea, Walton Nosé, Wilson Takashi Hida","doi":"10.2147/OPTH.S510850","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the performance of a self-refraction device (EyeQue Vision Check 2, EyeQue, USA) with autorefraction (OPD-Scan III, NIDEK) and subjective cycloplegic refraction in measuring refractive errors.</p><p><strong>Methods: </strong>This descriptive study included 80 eyes from 40 patients. Measurements were obtained using the portable EyeQue device, OPD-Scan III, and subjective cycloplegic refraction performed by an experienced examiner. Spherical equivalent (SE), cylindrical power, and axis values were analyzed using power vector decomposition (M, J0, J45) to improve accuracy in comparing methods. The main outcome was the agreement between self-refraction, autorefraction, and subjective refraction.</p><p><strong>Results: </strong>The EyeQue device showed lower variability and greater homogeneity in spherical measurements but exhibited lower precision for cylindrical power and axis than subjective refraction. Power vector analysis revealed that EyeQue overestimated spherical equivalent (M) and produced higher J0 values, suggesting a tendency to alter cylindrical correction. Although comparable to OPD-Scan in spherical refraction, EyeQue demonstrated inconsistencies in astigmatism correction, particularly in J45 components.</p><p><strong>Conclusion: </strong>The EyeQue device is a promising tool for large-scale screenings due to its affordability and portability. However, its limitations in astigmatism and axis measurements indicate that subjective refraction should complement rather than replace it. Therefore, further refinement and validation in diverse populations are recommended.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":"19 ","pages":"1085-1092"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11960455/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of Self-Test Refraction, Autorefraction, and Subjective Refraction.\",\"authors\":\"Abraão Ferreira de Sousa Neto Kós, Bernardo Kaplan Moscovici, Cesar Vilar, Mario Augusto Pereira Dias Chaves, Maíra Gomes Barbosa Da Silva, Maurício Agne Neuwald, André Lins De Medeiros, Jonathan Clive Lake, Antonio Francisco Pimenta Motta, Patrick Frensel de Moraes Tzelikis, Pedro Carlos Carricondo, Larissa Gouvea, Walton Nosé, Wilson Takashi Hida\",\"doi\":\"10.2147/OPTH.S510850\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare the performance of a self-refraction device (EyeQue Vision Check 2, EyeQue, USA) with autorefraction (OPD-Scan III, NIDEK) and subjective cycloplegic refraction in measuring refractive errors.</p><p><strong>Methods: </strong>This descriptive study included 80 eyes from 40 patients. Measurements were obtained using the portable EyeQue device, OPD-Scan III, and subjective cycloplegic refraction performed by an experienced examiner. Spherical equivalent (SE), cylindrical power, and axis values were analyzed using power vector decomposition (M, J0, J45) to improve accuracy in comparing methods. The main outcome was the agreement between self-refraction, autorefraction, and subjective refraction.</p><p><strong>Results: </strong>The EyeQue device showed lower variability and greater homogeneity in spherical measurements but exhibited lower precision for cylindrical power and axis than subjective refraction. Power vector analysis revealed that EyeQue overestimated spherical equivalent (M) and produced higher J0 values, suggesting a tendency to alter cylindrical correction. Although comparable to OPD-Scan in spherical refraction, EyeQue demonstrated inconsistencies in astigmatism correction, particularly in J45 components.</p><p><strong>Conclusion: </strong>The EyeQue device is a promising tool for large-scale screenings due to its affordability and portability. However, its limitations in astigmatism and axis measurements indicate that subjective refraction should complement rather than replace it. Therefore, further refinement and validation in diverse populations are recommended.</p>\",\"PeriodicalId\":93945,\"journal\":{\"name\":\"Clinical ophthalmology (Auckland, N.Z.)\",\"volume\":\"19 \",\"pages\":\"1085-1092\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11960455/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical ophthalmology (Auckland, N.Z.)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/OPTH.S510850\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S510850","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较自屈光仪(EyeQue Vision Check 2, EyeQue, USA)与自屈光仪(OPD-Scan III, NIDEK)和主观单眼麻痹性屈光仪在测量屈光误差方面的性能。方法:本描述性研究纳入40例患者80只眼。测量使用便携式EyeQue装置,OPD-Scan III,并由经验丰富的检查员进行主观单眼麻痹屈光检查。利用功率矢量分解(M, J0, J45)对球面等效(SE)、圆柱功率和轴向值进行分析,以提高比较方法的准确性。主要结果是自我折射、自我折射和主观折射的一致性。结果:EyeQue装置在球面测量中具有较低的可变性和较好的均匀性,但在柱面功率和轴上的精度低于主观折射。功率矢量分析显示,EyeQue高估了球面等效(M),产生了更高的J0值,表明有改变圆柱校正的趋势。虽然在球面折射方面与OPD-Scan相当,但EyeQue在像散校正方面表现出不一致,特别是在J45组件上。结论:EyeQue设备是一种很有前途的大规模筛查工具,因为它价格合理,携带方便。然而,它在散光和轴测量方面的局限性表明,主观折射应该补充而不是取代它。因此,建议在不同人群中进一步细化和验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Self-Test Refraction, Autorefraction, and Subjective Refraction.

Purpose: To compare the performance of a self-refraction device (EyeQue Vision Check 2, EyeQue, USA) with autorefraction (OPD-Scan III, NIDEK) and subjective cycloplegic refraction in measuring refractive errors.

Methods: This descriptive study included 80 eyes from 40 patients. Measurements were obtained using the portable EyeQue device, OPD-Scan III, and subjective cycloplegic refraction performed by an experienced examiner. Spherical equivalent (SE), cylindrical power, and axis values were analyzed using power vector decomposition (M, J0, J45) to improve accuracy in comparing methods. The main outcome was the agreement between self-refraction, autorefraction, and subjective refraction.

Results: The EyeQue device showed lower variability and greater homogeneity in spherical measurements but exhibited lower precision for cylindrical power and axis than subjective refraction. Power vector analysis revealed that EyeQue overestimated spherical equivalent (M) and produced higher J0 values, suggesting a tendency to alter cylindrical correction. Although comparable to OPD-Scan in spherical refraction, EyeQue demonstrated inconsistencies in astigmatism correction, particularly in J45 components.

Conclusion: The EyeQue device is a promising tool for large-scale screenings due to its affordability and portability. However, its limitations in astigmatism and axis measurements indicate that subjective refraction should complement rather than replace it. Therefore, further refinement and validation in diverse populations are recommended.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信