使用Advia 2120i分析仪,体外诱导的亨氏体对猫网织红细胞血红蛋白含量测量没有影响。

IF 1.9 2区 农林科学 Q2 VETERINARY SCIENCES
Journal of Feline Medicine and Surgery Pub Date : 2025-04-01 Epub Date: 2025-04-02 DOI:10.1177/1098612X251314709
Asger Lundorff Jensen, Julie Dreyer Vestergaard, Lise Nikolic Nielsen, Anne Kh Krogh, Rebecca Langhorn
{"title":"使用Advia 2120i分析仪,体外诱导的亨氏体对猫网织红细胞血红蛋白含量测量没有影响。","authors":"Asger Lundorff Jensen, Julie Dreyer Vestergaard, Lise Nikolic Nielsen, Anne Kh Krogh, Rebecca Langhorn","doi":"10.1177/1098612X251314709","DOIUrl":null,"url":null,"abstract":"<p><p>ObjectivesReticulocyte haemoglobin content (CHr) is a promising tool for evaluating iron status in dogs; however, its usefulness in cats varies. Heinz bodies interfere with haematological analyses on the Advia 120/2120i analyser (Siemens Healthineers), but the effect of Heinz bodies on CHr measurement in feline blood samples is unknown.MethodsIn an analytical intervention study, CHr concentration was measured pairwise in 30 feline blood samples with and without Heinz bodies chemically induced in vitro using 1-acetyl-2-phenylhydrazine (APH).ResultsThe percentage of Heinz bodies and the amount of Heinz body material were assessed by microscopy after staining with New Methylene Blue, and both increased significantly after in vitro APH incubation. After incubation, CHr levels decreased significantly in both samples without APH and in APH-treated samples, but no significant difference was detected between the samples with and without APH.Conclusions and relevanceIn vitro<i>-</i>induced Heinz bodies did not impact CHr levels. Explaining the lesser diagnostic utility of CHr measurements in cats compared with dogs as an effect of Heinz bodies is therefore not substantiated by this in vitro study. Accordingly, variations in feline patient populations and varying definitions of iron deficiency in previous studies are likely the main explanations for the lesser diagnostic utility of CHr measurements in cats.</p>","PeriodicalId":15851,"journal":{"name":"Journal of Feline Medicine and Surgery","volume":"27 4","pages":"1098612X251314709"},"PeriodicalIF":1.9000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11967230/pdf/","citationCount":"0","resultStr":"{\"title\":\"In vitro-induced Heinz bodies showed no impact on feline reticulocyte haemoglobin content measurement using the Advia 2120i analyser.\",\"authors\":\"Asger Lundorff Jensen, Julie Dreyer Vestergaard, Lise Nikolic Nielsen, Anne Kh Krogh, Rebecca Langhorn\",\"doi\":\"10.1177/1098612X251314709\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>ObjectivesReticulocyte haemoglobin content (CHr) is a promising tool for evaluating iron status in dogs; however, its usefulness in cats varies. Heinz bodies interfere with haematological analyses on the Advia 120/2120i analyser (Siemens Healthineers), but the effect of Heinz bodies on CHr measurement in feline blood samples is unknown.MethodsIn an analytical intervention study, CHr concentration was measured pairwise in 30 feline blood samples with and without Heinz bodies chemically induced in vitro using 1-acetyl-2-phenylhydrazine (APH).ResultsThe percentage of Heinz bodies and the amount of Heinz body material were assessed by microscopy after staining with New Methylene Blue, and both increased significantly after in vitro APH incubation. After incubation, CHr levels decreased significantly in both samples without APH and in APH-treated samples, but no significant difference was detected between the samples with and without APH.Conclusions and relevanceIn vitro<i>-</i>induced Heinz bodies did not impact CHr levels. Explaining the lesser diagnostic utility of CHr measurements in cats compared with dogs as an effect of Heinz bodies is therefore not substantiated by this in vitro study. Accordingly, variations in feline patient populations and varying definitions of iron deficiency in previous studies are likely the main explanations for the lesser diagnostic utility of CHr measurements in cats.</p>\",\"PeriodicalId\":15851,\"journal\":{\"name\":\"Journal of Feline Medicine and Surgery\",\"volume\":\"27 4\",\"pages\":\"1098612X251314709\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11967230/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Feline Medicine and Surgery\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1177/1098612X251314709\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/4/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Feline Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1177/1098612X251314709","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

目的网织红细胞血红蛋白含量(CHr)是一种很有前途的评估狗铁状态的工具;然而,它在猫身上的用处各不相同。亨氏体干扰Advia 120/2120i分析仪(西门子健康工程师)的血液学分析,但亨氏体对猫血液样本中CHr测量的影响尚不清楚。方法在分析性干预研究中,采用1-乙酰-2-苯肼(APH)体外化学诱导的30只有和没有亨氏体的猫血样品,两两测量CHr浓度。结果经新亚甲基蓝染色,镜检亨氏小体百分比和亨氏小体物质量,经APH体外培养后,亨氏小体百分比和亨氏小体物质量均显著增加。孵育后,未经APH处理的样品和经APH处理的样品的CHr水平均显著下降,但经APH处理的样品与未经APH处理的样品之间无显著差异。结论及相关性:体外诱导的亨氏体不影响CHr水平。因此,将猫的CHr测量的诊断效用较低解释为亨氏体的影响,并没有得到本体外研究的证实。因此,在以往的研究中,猫患者群体的差异和对缺铁的不同定义可能是猫CHr测量诊断效用较低的主要原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In vitro-induced Heinz bodies showed no impact on feline reticulocyte haemoglobin content measurement using the Advia 2120i analyser.

ObjectivesReticulocyte haemoglobin content (CHr) is a promising tool for evaluating iron status in dogs; however, its usefulness in cats varies. Heinz bodies interfere with haematological analyses on the Advia 120/2120i analyser (Siemens Healthineers), but the effect of Heinz bodies on CHr measurement in feline blood samples is unknown.MethodsIn an analytical intervention study, CHr concentration was measured pairwise in 30 feline blood samples with and without Heinz bodies chemically induced in vitro using 1-acetyl-2-phenylhydrazine (APH).ResultsThe percentage of Heinz bodies and the amount of Heinz body material were assessed by microscopy after staining with New Methylene Blue, and both increased significantly after in vitro APH incubation. After incubation, CHr levels decreased significantly in both samples without APH and in APH-treated samples, but no significant difference was detected between the samples with and without APH.Conclusions and relevanceIn vitro-induced Heinz bodies did not impact CHr levels. Explaining the lesser diagnostic utility of CHr measurements in cats compared with dogs as an effect of Heinz bodies is therefore not substantiated by this in vitro study. Accordingly, variations in feline patient populations and varying definitions of iron deficiency in previous studies are likely the main explanations for the lesser diagnostic utility of CHr measurements in cats.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
17.60%
发文量
254
审稿时长
8-16 weeks
期刊介绍: JFMS is an international, peer-reviewed journal aimed at both practitioners and researchers with an interest in the clinical veterinary healthcare of domestic cats. The journal is published monthly in two formats: ‘Classic’ editions containing high-quality original papers on all aspects of feline medicine and surgery, including basic research relevant to clinical practice; and dedicated ‘Clinical Practice’ editions primarily containing opinionated review articles providing state-of-the-art information for feline clinicians, along with other relevant articles such as consensus guidelines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信