超声乳化术中两个侧孔切口的比较。

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY
Huafang Guo, TingTing Peng, Wnjing Luo, Anqi Xie
{"title":"超声乳化术中两个侧孔切口的比较。","authors":"Huafang Guo, TingTing Peng, Wnjing Luo, Anqi Xie","doi":"10.1097/j.jcrs.0000000000001661","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this project is to compare the accuracy, safety, and consistency of near-square and asymmetric trapezoid side-port incisions in cataract surgery.</p><p><strong>Setting: </strong>Aier Eye Hospital of Wuhan University, Wuhan Hubei Province, China.</p><p><strong>Design: </strong>Prospective pilot study.</p><p><strong>Methods: </strong>The patients were divided into Groups A and B using the random number table method. Group A received a near-square side-port incision (SPI) with a 22G needle, and Group B received an asymmetric trapezoid SPI with a 15-degree blade. We contrasted the differences in incision length, width, and shape; surgical time; and postoperative intraocular pressure (IOP) between the two groups.</p><p><strong>Results: </strong>Eighty eyes from 80 patients were included. The mean external width of incision in Group A was much smaller than that in Group B (p < .01), while the internal width in Group A was significantly larger (p < .01). In Group A, there is no statistically significant difference between the external and internal incision diameters (p = .081). In Group B, the external diameter is obviously larger than the internal diameter (p < .01). The incision diameter consistency in Group A was higher than that in Group B. There was no statistically significant difference in incision length between the two groups (p = 0.67). One day after surgery, there were no significant differences in incision morphology (p = 1.0; .723) or operating time between the two groups (p = .89). There was no obvious incision leakage in either group after surgery (p =.337).</p><p><strong>Conclusions: </strong>The present study suggests that a near-square side-port with a 22G needle is smaller and results in better incision consistency. Moreover, the 22G needle is inexpensive and can be easily obtained.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of two side-port incisions in phacoemulsification.\",\"authors\":\"Huafang Guo, TingTing Peng, Wnjing Luo, Anqi Xie\",\"doi\":\"10.1097/j.jcrs.0000000000001661\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this project is to compare the accuracy, safety, and consistency of near-square and asymmetric trapezoid side-port incisions in cataract surgery.</p><p><strong>Setting: </strong>Aier Eye Hospital of Wuhan University, Wuhan Hubei Province, China.</p><p><strong>Design: </strong>Prospective pilot study.</p><p><strong>Methods: </strong>The patients were divided into Groups A and B using the random number table method. Group A received a near-square side-port incision (SPI) with a 22G needle, and Group B received an asymmetric trapezoid SPI with a 15-degree blade. We contrasted the differences in incision length, width, and shape; surgical time; and postoperative intraocular pressure (IOP) between the two groups.</p><p><strong>Results: </strong>Eighty eyes from 80 patients were included. The mean external width of incision in Group A was much smaller than that in Group B (p < .01), while the internal width in Group A was significantly larger (p < .01). In Group A, there is no statistically significant difference between the external and internal incision diameters (p = .081). In Group B, the external diameter is obviously larger than the internal diameter (p < .01). The incision diameter consistency in Group A was higher than that in Group B. There was no statistically significant difference in incision length between the two groups (p = 0.67). One day after surgery, there were no significant differences in incision morphology (p = 1.0; .723) or operating time between the two groups (p = .89). There was no obvious incision leakage in either group after surgery (p =.337).</p><p><strong>Conclusions: </strong>The present study suggests that a near-square side-port with a 22G needle is smaller and results in better incision consistency. Moreover, the 22G needle is inexpensive and can be easily obtained.</p>\",\"PeriodicalId\":15214,\"journal\":{\"name\":\"Journal of cataract and refractive surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cataract and refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/j.jcrs.0000000000001661\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001661","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较近方形和不对称梯形侧孔切口在白内障手术中的准确性、安全性和一致性。单位:武汉大学爱尔眼科医院,中国湖北省武汉市。设计:前瞻性先导研究。方法:采用随机数字表法将患者分为A组和B组。A组采用22G针近方侧口切口(SPI), B组采用15度刀片非对称梯形切口(SPI)。我们对比了切口长度、宽度和形状的差异;手术时间;两组术后眼压(IOP)比较。结果:纳入80例患者80只眼。A组切口外平均宽度明显小于B组(p < 0.01), A组切口内平均宽度明显大于B组(p < 0.01)。A组内、外切口直径差异无统计学意义(p = 0.081)。B组外径明显大于内径(p < 0.01)。A组切口直径一致性高于b组,两组切口长度差异无统计学意义(p = 0.67)。术后1天,两组切口形态差异无统计学意义(p = 1.0;.723)或手术时间(p = .89)。两组术后均无明显切口渗漏(p =.337)。结论:22G针近方侧孔更小,切口一致性更好。此外,22G的针头价格低廉,很容易获得。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of two side-port incisions in phacoemulsification.

Purpose: The purpose of this project is to compare the accuracy, safety, and consistency of near-square and asymmetric trapezoid side-port incisions in cataract surgery.

Setting: Aier Eye Hospital of Wuhan University, Wuhan Hubei Province, China.

Design: Prospective pilot study.

Methods: The patients were divided into Groups A and B using the random number table method. Group A received a near-square side-port incision (SPI) with a 22G needle, and Group B received an asymmetric trapezoid SPI with a 15-degree blade. We contrasted the differences in incision length, width, and shape; surgical time; and postoperative intraocular pressure (IOP) between the two groups.

Results: Eighty eyes from 80 patients were included. The mean external width of incision in Group A was much smaller than that in Group B (p < .01), while the internal width in Group A was significantly larger (p < .01). In Group A, there is no statistically significant difference between the external and internal incision diameters (p = .081). In Group B, the external diameter is obviously larger than the internal diameter (p < .01). The incision diameter consistency in Group A was higher than that in Group B. There was no statistically significant difference in incision length between the two groups (p = 0.67). One day after surgery, there were no significant differences in incision morphology (p = 1.0; .723) or operating time between the two groups (p = .89). There was no obvious incision leakage in either group after surgery (p =.337).

Conclusions: The present study suggests that a near-square side-port with a 22G needle is smaller and results in better incision consistency. Moreover, the 22G needle is inexpensive and can be easily obtained.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信