兽医学生不需要大象般的记忆:麻醉诱导前检查表的有效性。

IF 0.9 4区 农林科学 Q3 VETERINARY SCIENCES
Renata H Pinho, Alexandra R Robinson, Jessica Pang, Daniel S J Pang
{"title":"兽医学生不需要大象般的记忆:麻醉诱导前检查表的有效性。","authors":"Renata H Pinho, Alexandra R Robinson, Jessica Pang, Daniel S J Pang","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Checklists are widely recognized as safety measures in both aviation and human medicine, effectively preventing omissions caused by memory failures.</p><p><strong>Objective: </strong>To assess whether a pre-induction safety checklist completed by veterinary students during a spay/neuter laboratory minimized the number of incomplete pre-induction tasks.</p><p><strong>Participants and procedure: </strong>Third-year veterinary students (N = 53) managed the anesthesia of dogs and cats admitted for spay/neuter surgery under supervision. The use of a pre-induction checklist was mandatory to ensure appropriate preparation before anesthesia induction. Differences in checklist completeness between the 1st and 2nd wk of the spay/neuter laboratory were compared using Fisher's exact test.</p><p><strong>Results: </strong>Over 2 wk, 83 anesthesia procedures were completed. Use of the pre-induction checklist identified at least 1 omitted pre-induction task in 67.5% (56/83) of anesthesia procedures. The number of incomplete pre-induction tasks identified through use of the checklist decreased significantly from the 1st (82.9%, 34/41) to the 2nd (52.4%, 22/42) wk (odds ratio: 4.4, 95% CI: 1.7 to 11; <i>P</i> = 0.0046). The most frequently missed item was premeasuring the endotracheal tube insertion depth (42.2%, 35/83), followed by failure to leak-test the endotracheal tube cuffs and not having gauze available (15.7%, 13/83 for each). Finally, the checklist identified closed adjustable pressure-limiting valves in 4.8% (4/83) of cases.</p><p><strong>Conclusion and clinical relevance: </strong>The pre-induction checklist was effective in ensuring that veterinary students completed relevant pre-induction tasks during a spay/neuter laboratory. Results suggested the pre-induction checklist was a valuable tool that improved patient safety and prevented life-threatening equipment errors such as closed adjustable pressure-limiting valves.</p>","PeriodicalId":9429,"journal":{"name":"Canadian Veterinary Journal-revue Veterinaire Canadienne","volume":"66 4","pages":"409-416"},"PeriodicalIF":0.9000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11932370/pdf/","citationCount":"0","resultStr":"{\"title\":\"Veterinary students do not need an elephantine memory: Effectiveness of an anesthetic pre-induction checklist.\",\"authors\":\"Renata H Pinho, Alexandra R Robinson, Jessica Pang, Daniel S J Pang\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Checklists are widely recognized as safety measures in both aviation and human medicine, effectively preventing omissions caused by memory failures.</p><p><strong>Objective: </strong>To assess whether a pre-induction safety checklist completed by veterinary students during a spay/neuter laboratory minimized the number of incomplete pre-induction tasks.</p><p><strong>Participants and procedure: </strong>Third-year veterinary students (N = 53) managed the anesthesia of dogs and cats admitted for spay/neuter surgery under supervision. The use of a pre-induction checklist was mandatory to ensure appropriate preparation before anesthesia induction. Differences in checklist completeness between the 1st and 2nd wk of the spay/neuter laboratory were compared using Fisher's exact test.</p><p><strong>Results: </strong>Over 2 wk, 83 anesthesia procedures were completed. Use of the pre-induction checklist identified at least 1 omitted pre-induction task in 67.5% (56/83) of anesthesia procedures. The number of incomplete pre-induction tasks identified through use of the checklist decreased significantly from the 1st (82.9%, 34/41) to the 2nd (52.4%, 22/42) wk (odds ratio: 4.4, 95% CI: 1.7 to 11; <i>P</i> = 0.0046). The most frequently missed item was premeasuring the endotracheal tube insertion depth (42.2%, 35/83), followed by failure to leak-test the endotracheal tube cuffs and not having gauze available (15.7%, 13/83 for each). Finally, the checklist identified closed adjustable pressure-limiting valves in 4.8% (4/83) of cases.</p><p><strong>Conclusion and clinical relevance: </strong>The pre-induction checklist was effective in ensuring that veterinary students completed relevant pre-induction tasks during a spay/neuter laboratory. Results suggested the pre-induction checklist was a valuable tool that improved patient safety and prevented life-threatening equipment errors such as closed adjustable pressure-limiting valves.</p>\",\"PeriodicalId\":9429,\"journal\":{\"name\":\"Canadian Veterinary Journal-revue Veterinaire Canadienne\",\"volume\":\"66 4\",\"pages\":\"409-416\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11932370/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Veterinary Journal-revue Veterinaire Canadienne\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Veterinary Journal-revue Veterinaire Canadienne","FirstCategoryId":"97","ListUrlMain":"","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

背景:核对表在航空和人类医学中被广泛认为是一种安全措施,可以有效地防止由于记忆失败而导致的遗漏。目的:评估兽医学生在绝育实验室完成的诱导前安全检查表是否能最大限度地减少未完成的诱导前任务。参与者和程序:三年级兽医学生(N = 53)在监督下对接受绝育手术的狗和猫进行麻醉。使用诱导前检查表是强制性的,以确保麻醉诱导前的适当准备。使用Fisher精确检验比较绝育实验室第1周和第2周检查表完整性的差异。结果:2周内共完成83个麻醉过程。使用诱导前检查表,67.5%(56/83)的麻醉过程中至少有1项诱导前任务被遗漏。通过使用检查表识别的不完整诱导前任务数量从第1周(82.9%,34/41)到第2周(52.4%,22/42)显著减少(优势比:4.4,95% CI: 1.7 ~ 11;P = 0.0046)。漏检最多的是预测气管插管插入深度(42.2%,35/83),其次是气管插管袖口漏检失败和无纱布(15.7%,13/83)。最后,检查表在4.8%(4/83)的病例中发现了关闭的可调限压阀。结论及临床意义:诱导前检查表能有效地保证兽医学生在绝育实验中完成相关的诱导前任务。结果表明,感应前检查表是一种有价值的工具,可以提高患者的安全性,防止危及生命的设备错误,如关闭可调限压阀。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Veterinary students do not need an elephantine memory: Effectiveness of an anesthetic pre-induction checklist.

Background: Checklists are widely recognized as safety measures in both aviation and human medicine, effectively preventing omissions caused by memory failures.

Objective: To assess whether a pre-induction safety checklist completed by veterinary students during a spay/neuter laboratory minimized the number of incomplete pre-induction tasks.

Participants and procedure: Third-year veterinary students (N = 53) managed the anesthesia of dogs and cats admitted for spay/neuter surgery under supervision. The use of a pre-induction checklist was mandatory to ensure appropriate preparation before anesthesia induction. Differences in checklist completeness between the 1st and 2nd wk of the spay/neuter laboratory were compared using Fisher's exact test.

Results: Over 2 wk, 83 anesthesia procedures were completed. Use of the pre-induction checklist identified at least 1 omitted pre-induction task in 67.5% (56/83) of anesthesia procedures. The number of incomplete pre-induction tasks identified through use of the checklist decreased significantly from the 1st (82.9%, 34/41) to the 2nd (52.4%, 22/42) wk (odds ratio: 4.4, 95% CI: 1.7 to 11; P = 0.0046). The most frequently missed item was premeasuring the endotracheal tube insertion depth (42.2%, 35/83), followed by failure to leak-test the endotracheal tube cuffs and not having gauze available (15.7%, 13/83 for each). Finally, the checklist identified closed adjustable pressure-limiting valves in 4.8% (4/83) of cases.

Conclusion and clinical relevance: The pre-induction checklist was effective in ensuring that veterinary students completed relevant pre-induction tasks during a spay/neuter laboratory. Results suggested the pre-induction checklist was a valuable tool that improved patient safety and prevented life-threatening equipment errors such as closed adjustable pressure-limiting valves.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
10.00%
发文量
177
审稿时长
12-24 weeks
期刊介绍: The Canadian Veterinary Journal (CVJ) provides a forum for the discussion of all matters relevant to the veterinary profession. The mission of the Journal is to educate by informing readers of progress in clinical veterinary medicine, clinical veterinary research, and related fields of endeavor. The key objective of The CVJ is to promote the art and science of veterinary medicine and the betterment of animal health. A report suggesting that animals have been unnecessarily subjected to adverse, stressful, or harsh conditions or treatments will not be processed for publication. Experimental studies using animals will only be considered for publication if the studies have been approved by an institutional animal care committee, or equivalent, and the guidelines of the Canadian Council on Animal Care, or equivalent, have been followed by the author(s).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信