HEMP下油纸绝缘典型缺陷击穿特性及损伤机理

IF 2.9 3区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Feng Qin;Simeng Li;Wei Chen;Zhitong Cui;Xin Nie;Wei Wu
{"title":"HEMP下油纸绝缘典型缺陷击穿特性及损伤机理","authors":"Feng Qin;Simeng Li;Wei Chen;Zhitong Cui;Xin Nie;Wei Wu","doi":"10.1109/TDEI.2024.3479129","DOIUrl":null,"url":null,"abstract":"High-altitude electromagnetic pulses (HEMPs) can couple with power transmission and distribution lines, creating a nanosecond-level HEMP conductive environment that can degrade the insulation performance and even cause breakdown of distribution transformers, posing a threat to the safe operation of power systems. In this article, based on the main vulnerable parts identified in HEMP effect tests on distribution transformers, a typical defect model of oil-paper insulation was constructed, and an experimental platform was set up to study the breakdown characteristics of oil-paper insulation under HEMP. The process of charge accumulation was analyzed using finite element simulation, revealing the damage mechanism of oil-paper insulation under HEMP and other nanosecond pulses. The results show that the breakdown characteristics of oil-paper insulation under HEMP have a significant polarity effect, which is related to the accumulation of charges at the interface of oil-paper insulation. The accumulation of charges at the interface of oil-paper insulation is comparable to the nanosecond rise time of the HEMP waveform, resulting in a certain balance relationship in the location of breakdown points. Under negative-polarity HEMP, needle-plate defect structures have a higher proportion of breakdown at the trailing edge of the waveform, indicating that the energy provided within the rise time of the HEMP waveform is slightly insufficient.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"32 2","pages":"1046-1055"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Breakdown Characteristics and Damage Mechanism of Typical Defects in Oil-Paper Insulation Under HEMP\",\"authors\":\"Feng Qin;Simeng Li;Wei Chen;Zhitong Cui;Xin Nie;Wei Wu\",\"doi\":\"10.1109/TDEI.2024.3479129\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High-altitude electromagnetic pulses (HEMPs) can couple with power transmission and distribution lines, creating a nanosecond-level HEMP conductive environment that can degrade the insulation performance and even cause breakdown of distribution transformers, posing a threat to the safe operation of power systems. In this article, based on the main vulnerable parts identified in HEMP effect tests on distribution transformers, a typical defect model of oil-paper insulation was constructed, and an experimental platform was set up to study the breakdown characteristics of oil-paper insulation under HEMP. The process of charge accumulation was analyzed using finite element simulation, revealing the damage mechanism of oil-paper insulation under HEMP and other nanosecond pulses. The results show that the breakdown characteristics of oil-paper insulation under HEMP have a significant polarity effect, which is related to the accumulation of charges at the interface of oil-paper insulation. The accumulation of charges at the interface of oil-paper insulation is comparable to the nanosecond rise time of the HEMP waveform, resulting in a certain balance relationship in the location of breakdown points. Under negative-polarity HEMP, needle-plate defect structures have a higher proportion of breakdown at the trailing edge of the waveform, indicating that the energy provided within the rise time of the HEMP waveform is slightly insufficient.\",\"PeriodicalId\":13247,\"journal\":{\"name\":\"IEEE Transactions on Dielectrics and Electrical Insulation\",\"volume\":\"32 2\",\"pages\":\"1046-1055\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Dielectrics and Electrical Insulation\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10714454/\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10714454/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

高空电磁脉冲(HEMPs)会与输配电线路耦合,产生纳秒级的HEMP导电环境,会降低配电变压器的绝缘性能,甚至导致配电变压器击穿,对电力系统的安全运行构成威胁。本文在对配电变压器进行HEMP效应试验中确定的主要易损件的基础上,建立了油纸绝缘的典型缺陷模型,搭建了实验平台,研究了HEMP作用下油纸绝缘的击穿特性。利用有限元模拟分析了电荷积累过程,揭示了麻麻和其他纳秒脉冲作用下油纸绝缘的损伤机理。结果表明:在HEMP作用下,油纸绝缘击穿特性具有显著的极性效应,这与油纸绝缘界面电荷的积累有关。油纸绝缘界面电荷的积累与HEMP波形的纳秒级上升时间相当,导致击穿点位置存在一定的平衡关系。负极性HEMP下,针板缺陷结构在波形尾缘击穿比例较高,说明在HEMP波形上升时间内提供的能量略不足。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Breakdown Characteristics and Damage Mechanism of Typical Defects in Oil-Paper Insulation Under HEMP
High-altitude electromagnetic pulses (HEMPs) can couple with power transmission and distribution lines, creating a nanosecond-level HEMP conductive environment that can degrade the insulation performance and even cause breakdown of distribution transformers, posing a threat to the safe operation of power systems. In this article, based on the main vulnerable parts identified in HEMP effect tests on distribution transformers, a typical defect model of oil-paper insulation was constructed, and an experimental platform was set up to study the breakdown characteristics of oil-paper insulation under HEMP. The process of charge accumulation was analyzed using finite element simulation, revealing the damage mechanism of oil-paper insulation under HEMP and other nanosecond pulses. The results show that the breakdown characteristics of oil-paper insulation under HEMP have a significant polarity effect, which is related to the accumulation of charges at the interface of oil-paper insulation. The accumulation of charges at the interface of oil-paper insulation is comparable to the nanosecond rise time of the HEMP waveform, resulting in a certain balance relationship in the location of breakdown points. Under negative-polarity HEMP, needle-plate defect structures have a higher proportion of breakdown at the trailing edge of the waveform, indicating that the energy provided within the rise time of the HEMP waveform is slightly insufficient.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Dielectrics and Electrical Insulation
IEEE Transactions on Dielectrics and Electrical Insulation 工程技术-工程:电子与电气
CiteScore
6.00
自引率
22.60%
发文量
309
审稿时长
5.2 months
期刊介绍: Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信