一种考虑突发性水污染事件的自适应水风光伏一体化基地短期调度新方案

IF 7.1 2区 工程技术 Q1 ENERGY & FUELS
Gang Zhang, Bao Zhang, Tuo Xie, Kaoshe Zhang
{"title":"一种考虑突发性水污染事件的自适应水风光伏一体化基地短期调度新方案","authors":"Gang Zhang,&nbsp;Bao Zhang,&nbsp;Tuo Xie,&nbsp;Kaoshe Zhang","doi":"10.1016/j.seta.2025.104296","DOIUrl":null,"url":null,"abstract":"<div><div>Hydro–wind–photovoltaic complementarity is an important way to promote new energy consumption. Aiming at the demand for emergency dispatching for sudden water pollution incidents in cascade hydropower stations, this paper proposes a short-term optimal scheduling solution for hydro-wind-photovoltaic integrated base considering sudden water pollution incidents. Firstly, a day-ahead dispatching model is established, and the DBO algorithm is employed to determine the optimal day-ahead dispatching plan. Secondly, an emergency dispatching model is established with the objective of the shortest pollutant arrival time and the largest concentration accumulation value. The power generation plan deviation as the constraints to formulate an emergency dispatching plan after a sudden water pollution incident. Finally, a hydro-wind-photovoltaic integrated base under construction in Guizhou Province, China, is used as an example for the study. The results show that the emergency dispatching plan does not significantly reduce the system power generation performance (the average daily power generation decreases by only 0.27%, and the residual load fluctuation increases by only 0.15%), but it can shorten the pollutant arrival time by 10.76%, increase the concentration accumulation value by 1.61%, and improve the ability of the integrated base to cope with the sudden pollution incidents.</div></div>","PeriodicalId":56019,"journal":{"name":"Sustainable Energy Technologies and Assessments","volume":"76 ","pages":"Article 104296"},"PeriodicalIF":7.1000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel adaptive hydro-wind-photovoltaic integrated base short-term scheduling solution: Considering sudden water pollution incidents\",\"authors\":\"Gang Zhang,&nbsp;Bao Zhang,&nbsp;Tuo Xie,&nbsp;Kaoshe Zhang\",\"doi\":\"10.1016/j.seta.2025.104296\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Hydro–wind–photovoltaic complementarity is an important way to promote new energy consumption. Aiming at the demand for emergency dispatching for sudden water pollution incidents in cascade hydropower stations, this paper proposes a short-term optimal scheduling solution for hydro-wind-photovoltaic integrated base considering sudden water pollution incidents. Firstly, a day-ahead dispatching model is established, and the DBO algorithm is employed to determine the optimal day-ahead dispatching plan. Secondly, an emergency dispatching model is established with the objective of the shortest pollutant arrival time and the largest concentration accumulation value. The power generation plan deviation as the constraints to formulate an emergency dispatching plan after a sudden water pollution incident. Finally, a hydro-wind-photovoltaic integrated base under construction in Guizhou Province, China, is used as an example for the study. The results show that the emergency dispatching plan does not significantly reduce the system power generation performance (the average daily power generation decreases by only 0.27%, and the residual load fluctuation increases by only 0.15%), but it can shorten the pollutant arrival time by 10.76%, increase the concentration accumulation value by 1.61%, and improve the ability of the integrated base to cope with the sudden pollution incidents.</div></div>\",\"PeriodicalId\":56019,\"journal\":{\"name\":\"Sustainable Energy Technologies and Assessments\",\"volume\":\"76 \",\"pages\":\"Article 104296\"},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sustainable Energy Technologies and Assessments\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2213138825001274\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sustainable Energy Technologies and Assessments","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213138825001274","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

水风互补是促进新能源消费的重要途径。针对梯级水电站突发性水污染事件应急调度需求,提出了考虑突发性水污染事件的水风光伏综合基地短期最优调度方案。首先,建立日前调度模型,采用DBO算法确定最优日前调度方案;其次,以污染物到达时间最短、浓度积累值最大为目标,建立了应急调度模型;以发电计划偏差为约束,制定突发性水污染事件应急调度方案。最后,以中国贵州省正在建设的水风光伏一体化基地为例进行研究。结果表明,应急调度方案并未显著降低系统发电性能(日均发电量仅下降0.27%,剩余负荷波动仅增加0.15%),但可使污染物到达时间缩短10.76%,浓度积累值提高1.61%,提高综合基地应对突发污染事件的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel adaptive hydro-wind-photovoltaic integrated base short-term scheduling solution: Considering sudden water pollution incidents
Hydro–wind–photovoltaic complementarity is an important way to promote new energy consumption. Aiming at the demand for emergency dispatching for sudden water pollution incidents in cascade hydropower stations, this paper proposes a short-term optimal scheduling solution for hydro-wind-photovoltaic integrated base considering sudden water pollution incidents. Firstly, a day-ahead dispatching model is established, and the DBO algorithm is employed to determine the optimal day-ahead dispatching plan. Secondly, an emergency dispatching model is established with the objective of the shortest pollutant arrival time and the largest concentration accumulation value. The power generation plan deviation as the constraints to formulate an emergency dispatching plan after a sudden water pollution incident. Finally, a hydro-wind-photovoltaic integrated base under construction in Guizhou Province, China, is used as an example for the study. The results show that the emergency dispatching plan does not significantly reduce the system power generation performance (the average daily power generation decreases by only 0.27%, and the residual load fluctuation increases by only 0.15%), but it can shorten the pollutant arrival time by 10.76%, increase the concentration accumulation value by 1.61%, and improve the ability of the integrated base to cope with the sudden pollution incidents.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sustainable Energy Technologies and Assessments
Sustainable Energy Technologies and Assessments Energy-Renewable Energy, Sustainability and the Environment
CiteScore
12.70
自引率
12.50%
发文量
1091
期刊介绍: Encouraging a transition to a sustainable energy future is imperative for our world. Technologies that enable this shift in various sectors like transportation, heating, and power systems are of utmost importance. Sustainable Energy Technologies and Assessments welcomes papers focusing on a range of aspects and levels of technological advancements in energy generation and utilization. The aim is to reduce the negative environmental impact associated with energy production and consumption, spanning from laboratory experiments to real-world applications in the commercial sector.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信