{"title":"超高效液相色谱-串联质谱法测定人血浆中比索洛尔的快速灵敏方法","authors":"Yihong Jiang, Yaling Niu, Congchao Ning, Feng Qin, Chengda Yan, Xiumei Lu","doi":"10.1002/bmc.70054","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>A rapid and sensitive ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) method for the determination of bisoprolol in human plasma was established and validated. The sample was pretreated by methanol precipitation protein, and the isotope bisoprolol-d<sub>5</sub> was used as the internal standard. The chromatographic column was ACQUITY UPLC BEH-C<sub>18</sub> column (2.1 × 50 mm, 1.7 μm), with methanol and 0.2% formic acid aqueous solution as mobile phase for gradient elution. The electrospray ionization (ESI) source was used in the positive ion mode, and the multiple reaction monitoring (MRM) mode was used. The total running time was only 2.00 min. The correlation coefficient was good (<i>r</i> > 0.99) in the linear range of 0.0200–40.0 ng/mL. The lower limit of quantitation (LLOQ) was 20.0 pg/mL. The intrabatch and interbatch precisions were not more than 8.9% and 9.2%. The intrabatch and interbatch accuracies were −7.9% ~ 6.3% and −6.9% ~ 5.0%. The method was fully validated including whole blood stability and reinjection reproducibility and successfully applied to the pharmacokinetic study of 5-mg bisoprolol in healthy volunteers, which 93.1% incurred samples reanalysis (ISR) met the criteria. Compared with the reported methods, this method had the highest sensitivity and fast analysis speed.</p>\n </div>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 5","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Rapid and Sensitive Method for the Determination of Bisoprolol in Human Plasma by Ultra Performance Liquid Chromatography–Tandem Mass Spectrometry\",\"authors\":\"Yihong Jiang, Yaling Niu, Congchao Ning, Feng Qin, Chengda Yan, Xiumei Lu\",\"doi\":\"10.1002/bmc.70054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>A rapid and sensitive ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) method for the determination of bisoprolol in human plasma was established and validated. The sample was pretreated by methanol precipitation protein, and the isotope bisoprolol-d<sub>5</sub> was used as the internal standard. The chromatographic column was ACQUITY UPLC BEH-C<sub>18</sub> column (2.1 × 50 mm, 1.7 μm), with methanol and 0.2% formic acid aqueous solution as mobile phase for gradient elution. The electrospray ionization (ESI) source was used in the positive ion mode, and the multiple reaction monitoring (MRM) mode was used. The total running time was only 2.00 min. The correlation coefficient was good (<i>r</i> > 0.99) in the linear range of 0.0200–40.0 ng/mL. The lower limit of quantitation (LLOQ) was 20.0 pg/mL. The intrabatch and interbatch precisions were not more than 8.9% and 9.2%. The intrabatch and interbatch accuracies were −7.9% ~ 6.3% and −6.9% ~ 5.0%. The method was fully validated including whole blood stability and reinjection reproducibility and successfully applied to the pharmacokinetic study of 5-mg bisoprolol in healthy volunteers, which 93.1% incurred samples reanalysis (ISR) met the criteria. Compared with the reported methods, this method had the highest sensitivity and fast analysis speed.</p>\\n </div>\",\"PeriodicalId\":8861,\"journal\":{\"name\":\"Biomedical Chromatography\",\"volume\":\"39 5\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-04-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Chromatography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bmc.70054\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.70054","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
A Rapid and Sensitive Method for the Determination of Bisoprolol in Human Plasma by Ultra Performance Liquid Chromatography–Tandem Mass Spectrometry
A rapid and sensitive ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) method for the determination of bisoprolol in human plasma was established and validated. The sample was pretreated by methanol precipitation protein, and the isotope bisoprolol-d5 was used as the internal standard. The chromatographic column was ACQUITY UPLC BEH-C18 column (2.1 × 50 mm, 1.7 μm), with methanol and 0.2% formic acid aqueous solution as mobile phase for gradient elution. The electrospray ionization (ESI) source was used in the positive ion mode, and the multiple reaction monitoring (MRM) mode was used. The total running time was only 2.00 min. The correlation coefficient was good (r > 0.99) in the linear range of 0.0200–40.0 ng/mL. The lower limit of quantitation (LLOQ) was 20.0 pg/mL. The intrabatch and interbatch precisions were not more than 8.9% and 9.2%. The intrabatch and interbatch accuracies were −7.9% ~ 6.3% and −6.9% ~ 5.0%. The method was fully validated including whole blood stability and reinjection reproducibility and successfully applied to the pharmacokinetic study of 5-mg bisoprolol in healthy volunteers, which 93.1% incurred samples reanalysis (ISR) met the criteria. Compared with the reported methods, this method had the highest sensitivity and fast analysis speed.
期刊介绍:
Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.