高度非球面镜片对眼周长度和不对称性变化的影响。

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY
Ophthalmic and Physiological Optics Pub Date : 2025-07-01 Epub Date: 2025-03-29 DOI:10.1111/opo.13500
Yingying Huang, Xue Li, Yanqing Wang, Björn Drobe, Hao Chen, Jinhua Bao
{"title":"高度非球面镜片对眼周长度和不对称性变化的影响。","authors":"Yingying Huang, Xue Li, Yanqing Wang, Björn Drobe, Hao Chen, Jinhua Bao","doi":"10.1111/opo.13500","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Spectacle lenses with highly aspherical lenslets (HAL) have been shown to slow myopia progression and axial length (AL) elongation effectively. The effects of HAL on peripheral eye length (PEL) and peripheral refraction (PR) were investigated in children who continued wearing HAL or switched from single-vision spectacle lenses (SVL) or spectacle lenses with slightly aspherical lenslets (SAL) to HAL.</p><p><strong>Methods: </strong>Fifty-two participants who had worn HAL for 2 years continued their use (HAL group), while 51 and 48 participants who had originally worn SAL or SVL for 2 years switched to HAL (SAL-HAL and SVL-HAL groups, respectively) in Year 3. A new SVL group of 56 participants, 10-15 years of age, was enrolled in Year 3 (new-SVL group). PEL and PR were measured every 10° from 30° nasal to 30° temporal and from 30° superior to 10° inferior retina.</p><p><strong>Results: </strong>There were significant differences in the changes in AL and PEL on the temporal side among the groups (all p ≤ 0.001). All three HAL groups exhibited less elongation than the new-SVL group. PR changes in the parafoveal temporal (p = 0.002) and superior (p = 0.001) regions differed among the groups; the new-SVL group progressed more than the other three groups. The AL in the new-SVL group exhibited greater elongation than the PEL (all p < 0.02). However, there were no significant differences between the AL and PEL changes in the three HAL groups (all p > 0.05).</p><p><strong>Conclusions: </strong>Compared with wearing SVL, switching to or continuing to wear HAL could slow central and temporal elongation of eye length. Wearing HAL could impact retinal steepness and symmetry.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":" ","pages":"1040-1048"},"PeriodicalIF":2.8000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12153024/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of spectacle lenses with highly aspherical lenslets on changes in peripheral eye length and asymmetry.\",\"authors\":\"Yingying Huang, Xue Li, Yanqing Wang, Björn Drobe, Hao Chen, Jinhua Bao\",\"doi\":\"10.1111/opo.13500\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Spectacle lenses with highly aspherical lenslets (HAL) have been shown to slow myopia progression and axial length (AL) elongation effectively. The effects of HAL on peripheral eye length (PEL) and peripheral refraction (PR) were investigated in children who continued wearing HAL or switched from single-vision spectacle lenses (SVL) or spectacle lenses with slightly aspherical lenslets (SAL) to HAL.</p><p><strong>Methods: </strong>Fifty-two participants who had worn HAL for 2 years continued their use (HAL group), while 51 and 48 participants who had originally worn SAL or SVL for 2 years switched to HAL (SAL-HAL and SVL-HAL groups, respectively) in Year 3. A new SVL group of 56 participants, 10-15 years of age, was enrolled in Year 3 (new-SVL group). PEL and PR were measured every 10° from 30° nasal to 30° temporal and from 30° superior to 10° inferior retina.</p><p><strong>Results: </strong>There were significant differences in the changes in AL and PEL on the temporal side among the groups (all p ≤ 0.001). All three HAL groups exhibited less elongation than the new-SVL group. PR changes in the parafoveal temporal (p = 0.002) and superior (p = 0.001) regions differed among the groups; the new-SVL group progressed more than the other three groups. The AL in the new-SVL group exhibited greater elongation than the PEL (all p < 0.02). However, there were no significant differences between the AL and PEL changes in the three HAL groups (all p > 0.05).</p><p><strong>Conclusions: </strong>Compared with wearing SVL, switching to or continuing to wear HAL could slow central and temporal elongation of eye length. Wearing HAL could impact retinal steepness and symmetry.</p>\",\"PeriodicalId\":19522,\"journal\":{\"name\":\"Ophthalmic and Physiological Optics\",\"volume\":\" \",\"pages\":\"1040-1048\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2025-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12153024/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic and Physiological Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/opo.13500\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13500","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:高度非球面透镜(HAL)的眼镜镜片已被证明可以有效地减缓近视的进展和轴长(AL)伸长。研究了HAL对继续佩戴HAL或从单视力眼镜镜片(SVL)或微非晶状体眼镜镜片(SAL)切换到HAL的儿童外周眼长(PEL)和外周屈光度(PR)的影响。方法:52名使用HAL 2年的参与者继续使用HAL (HAL组),而51名和48名最初使用SAL或SVL 2年的参与者在第3年切换到HAL(分别为SAL-HAL和SVL-HAL组)。新的SVL组有56名参与者,年龄在10-15岁,在第三年(新SVL组)注册。从30°鼻到30°颞,从30°视网膜上到10°视网膜下,每10°测量一次PEL和PR。结果:两组患者颞侧AL、PEL变化差异有统计学意义(p均≤0.001)。三个HAL组的伸长率均低于新svl组。颞中央凹旁区(p = 0.002)和上区(p = 0.001)的PR变化在组间存在差异;新svl组比其他三组进展更快。新svl组AL的伸长率高于PEL (p < 0.05)。结论:与佩戴SVL相比,切换或继续佩戴HAL可减缓中央和颞部眼长延长。佩戴HAL会影响视网膜的陡峭度和对称性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of spectacle lenses with highly aspherical lenslets on changes in peripheral eye length and asymmetry.

Purpose: Spectacle lenses with highly aspherical lenslets (HAL) have been shown to slow myopia progression and axial length (AL) elongation effectively. The effects of HAL on peripheral eye length (PEL) and peripheral refraction (PR) were investigated in children who continued wearing HAL or switched from single-vision spectacle lenses (SVL) or spectacle lenses with slightly aspherical lenslets (SAL) to HAL.

Methods: Fifty-two participants who had worn HAL for 2 years continued their use (HAL group), while 51 and 48 participants who had originally worn SAL or SVL for 2 years switched to HAL (SAL-HAL and SVL-HAL groups, respectively) in Year 3. A new SVL group of 56 participants, 10-15 years of age, was enrolled in Year 3 (new-SVL group). PEL and PR were measured every 10° from 30° nasal to 30° temporal and from 30° superior to 10° inferior retina.

Results: There were significant differences in the changes in AL and PEL on the temporal side among the groups (all p ≤ 0.001). All three HAL groups exhibited less elongation than the new-SVL group. PR changes in the parafoveal temporal (p = 0.002) and superior (p = 0.001) regions differed among the groups; the new-SVL group progressed more than the other three groups. The AL in the new-SVL group exhibited greater elongation than the PEL (all p < 0.02). However, there were no significant differences between the AL and PEL changes in the three HAL groups (all p > 0.05).

Conclusions: Compared with wearing SVL, switching to or continuing to wear HAL could slow central and temporal elongation of eye length. Wearing HAL could impact retinal steepness and symmetry.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
13.80%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry. OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信