{"title":"卵圆孔闭合术后使用闭合器与人工压迫止血的对比。","authors":"Saif Zako, David Naguib, Kathrin Klein, Asena Öz, Carolin Helten, Philipp Mourikis, Daniel Metzen, Malte Kelm, Tobias Zeus, Amin Polzin","doi":"10.25270/jic/25.00021","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Venous access plays a crucial role in various interventional cardiology procedures, including percutaneous patent foramen ovale (PFO) closure. Traditionally, manual compression has been the standard method for achieving hemostasis following venous access. However, this approach may be associated with potential complications such as puncture site bleedings. The aim of the study was to compare the safety and efficacy of different venous closure techniques.</p><p><strong>Methods: </strong>The authors conducted a single-center observational study of 220 patients undergoing PFO closure. The study quasi-randomized participants to 1 of 3 methods: Z-suture closure, Perclose ProGlide suture-mediated closure (Abbott), and manual compression. The primary outcome was the occurrence of bleeding events, classified according to the standardized Bleeding Academic Research Consortium (BARC) classification system.</p><p><strong>Results: </strong>Bleeding events were not significantly different between the closure groups. Of the patients who received manual compression, 14.2% (n = 17) experienced BARC bleeding events of 2 or higher. In the Z-suture group, 14.5% (n = 7) of patients had BARC bleeding events of 2 or higher. In the ProGlide group, 15% (n = 8) of patients experienced such events (P = .9). Only 1 patient in the manual compression group experienced a severe bleeding event (BARC 3). However, no cases of BARC 4 or 5 occurred in any of the closure groups.</p><p><strong>Conclusions: </strong>The Z-suture and ProGlide methods are safe and efficient for venous occlusion after percutaneous PFO closure compared with manual compression.</p>","PeriodicalId":49261,"journal":{"name":"Journal of Invasive Cardiology","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2025-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Closure devices versus manual compression to achieve hemostasis post-patent foramen ovale closure.\",\"authors\":\"Saif Zako, David Naguib, Kathrin Klein, Asena Öz, Carolin Helten, Philipp Mourikis, Daniel Metzen, Malte Kelm, Tobias Zeus, Amin Polzin\",\"doi\":\"10.25270/jic/25.00021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Venous access plays a crucial role in various interventional cardiology procedures, including percutaneous patent foramen ovale (PFO) closure. Traditionally, manual compression has been the standard method for achieving hemostasis following venous access. However, this approach may be associated with potential complications such as puncture site bleedings. The aim of the study was to compare the safety and efficacy of different venous closure techniques.</p><p><strong>Methods: </strong>The authors conducted a single-center observational study of 220 patients undergoing PFO closure. The study quasi-randomized participants to 1 of 3 methods: Z-suture closure, Perclose ProGlide suture-mediated closure (Abbott), and manual compression. The primary outcome was the occurrence of bleeding events, classified according to the standardized Bleeding Academic Research Consortium (BARC) classification system.</p><p><strong>Results: </strong>Bleeding events were not significantly different between the closure groups. Of the patients who received manual compression, 14.2% (n = 17) experienced BARC bleeding events of 2 or higher. In the Z-suture group, 14.5% (n = 7) of patients had BARC bleeding events of 2 or higher. In the ProGlide group, 15% (n = 8) of patients experienced such events (P = .9). Only 1 patient in the manual compression group experienced a severe bleeding event (BARC 3). However, no cases of BARC 4 or 5 occurred in any of the closure groups.</p><p><strong>Conclusions: </strong>The Z-suture and ProGlide methods are safe and efficient for venous occlusion after percutaneous PFO closure compared with manual compression.</p>\",\"PeriodicalId\":49261,\"journal\":{\"name\":\"Journal of Invasive Cardiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2025-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Invasive Cardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.25270/jic/25.00021\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Invasive Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.25270/jic/25.00021","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Closure devices versus manual compression to achieve hemostasis post-patent foramen ovale closure.

Objectives: Venous access plays a crucial role in various interventional cardiology procedures, including percutaneous patent foramen ovale (PFO) closure. Traditionally, manual compression has been the standard method for achieving hemostasis following venous access. However, this approach may be associated with potential complications such as puncture site bleedings. The aim of the study was to compare the safety and efficacy of different venous closure techniques.

Methods: The authors conducted a single-center observational study of 220 patients undergoing PFO closure. The study quasi-randomized participants to 1 of 3 methods: Z-suture closure, Perclose ProGlide suture-mediated closure (Abbott), and manual compression. The primary outcome was the occurrence of bleeding events, classified according to the standardized Bleeding Academic Research Consortium (BARC) classification system.

Results: Bleeding events were not significantly different between the closure groups. Of the patients who received manual compression, 14.2% (n = 17) experienced BARC bleeding events of 2 or higher. In the Z-suture group, 14.5% (n = 7) of patients had BARC bleeding events of 2 or higher. In the ProGlide group, 15% (n = 8) of patients experienced such events (P = .9). Only 1 patient in the manual compression group experienced a severe bleeding event (BARC 3). However, no cases of BARC 4 or 5 occurred in any of the closure groups.

Conclusions: The Z-suture and ProGlide methods are safe and efficient for venous occlusion after percutaneous PFO closure compared with manual compression.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Invasive Cardiology
Journal of Invasive Cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
6.70%
发文量
214
审稿时长
3-8 weeks
期刊介绍: The Journal of Invasive Cardiology will consider for publication suitable articles on topics pertaining to the invasive treatment of patients with cardiovascular disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信