{"title":"Hologic LOCalizer™ RFID 标签用于乳腺病灶术前定位的评估:单中心经验。","authors":"Charlotte Munday, Anmol Malhotra, Sawsan Taif, Adeola Omotade, Arathi Menon, Kefah Mokbel","doi":"10.3390/diagnostics15060746","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background</b>: The increasing detection of non-palpable breast lesions necessitates accurate preoperative localization to ensure complete excision while preserving healthy tissue and optimizing cosmetic outcomes. Traditional wire-guided localization (WL) has been the gold standard; however, it has several drawbacks, including patient discomfort and scheduling challenges. This study evaluates the accuracy and feasibility of radiofrequency identification (RFID) tag localization using the Hologic LOCalizer™ system as an alternative technique. <b>Methods</b>: This retrospective study included 258 consecutive patients who underwent image-guided RFID tag localization from March 2021 to February 2023 from a single-center London breast unit. The primary outcome measured was the accuracy of RFID tag placement, defined as within 10 mm of the target lesion on post-clip mammograms. Secondary outcomes included type and size of lesions, re-excision rates, review of post-operative specimen radiographs, and patient demographics. <b>Results</b>: A total of 297 RFID tags were placed, with 95.6% accurately positioned within the target range. The median target size was 29 mm, with the most common abnormalities being mass lesions (64%). Among the 13 inaccurately placed RFID tags (4.4%), all were identified preoperatively, with two requiring additional wire placements. RFID tags were successfully identified in 92% of specimen radiographs, and 8% of patients required re-excision due to positive or close margins. Notably, patients with multiple RFID tags showed a higher incidence of re-excision. <b>Conclusions</b>: The LOCalizer™ RFID system demonstrated a high accuracy rate for preoperative localization of breast lesions, presenting a viable alternative to WL. This technique improves surgical scheduling flexibility and enhances patient comfort. Comparative studies with other wire-free localization technologies, such as magnetic seeds and radar reflectors, are needed to determine the optimal approach for clinical practice.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"15 6","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11941596/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Hologic LOCalizer™ RFID Tags for Preoperative Localization of Breast Lesions: A Single-Center Experience.\",\"authors\":\"Charlotte Munday, Anmol Malhotra, Sawsan Taif, Adeola Omotade, Arathi Menon, Kefah Mokbel\",\"doi\":\"10.3390/diagnostics15060746\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background</b>: The increasing detection of non-palpable breast lesions necessitates accurate preoperative localization to ensure complete excision while preserving healthy tissue and optimizing cosmetic outcomes. Traditional wire-guided localization (WL) has been the gold standard; however, it has several drawbacks, including patient discomfort and scheduling challenges. This study evaluates the accuracy and feasibility of radiofrequency identification (RFID) tag localization using the Hologic LOCalizer™ system as an alternative technique. <b>Methods</b>: This retrospective study included 258 consecutive patients who underwent image-guided RFID tag localization from March 2021 to February 2023 from a single-center London breast unit. The primary outcome measured was the accuracy of RFID tag placement, defined as within 10 mm of the target lesion on post-clip mammograms. Secondary outcomes included type and size of lesions, re-excision rates, review of post-operative specimen radiographs, and patient demographics. <b>Results</b>: A total of 297 RFID tags were placed, with 95.6% accurately positioned within the target range. The median target size was 29 mm, with the most common abnormalities being mass lesions (64%). Among the 13 inaccurately placed RFID tags (4.4%), all were identified preoperatively, with two requiring additional wire placements. RFID tags were successfully identified in 92% of specimen radiographs, and 8% of patients required re-excision due to positive or close margins. Notably, patients with multiple RFID tags showed a higher incidence of re-excision. <b>Conclusions</b>: The LOCalizer™ RFID system demonstrated a high accuracy rate for preoperative localization of breast lesions, presenting a viable alternative to WL. This technique improves surgical scheduling flexibility and enhances patient comfort. Comparative studies with other wire-free localization technologies, such as magnetic seeds and radar reflectors, are needed to determine the optimal approach for clinical practice.</p>\",\"PeriodicalId\":11225,\"journal\":{\"name\":\"Diagnostics\",\"volume\":\"15 6\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11941596/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/diagnostics15060746\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics15060746","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Hologic LOCalizer™ RFID Tags for Preoperative Localization of Breast Lesions: A Single-Center Experience.

Background: The increasing detection of non-palpable breast lesions necessitates accurate preoperative localization to ensure complete excision while preserving healthy tissue and optimizing cosmetic outcomes. Traditional wire-guided localization (WL) has been the gold standard; however, it has several drawbacks, including patient discomfort and scheduling challenges. This study evaluates the accuracy and feasibility of radiofrequency identification (RFID) tag localization using the Hologic LOCalizer™ system as an alternative technique. Methods: This retrospective study included 258 consecutive patients who underwent image-guided RFID tag localization from March 2021 to February 2023 from a single-center London breast unit. The primary outcome measured was the accuracy of RFID tag placement, defined as within 10 mm of the target lesion on post-clip mammograms. Secondary outcomes included type and size of lesions, re-excision rates, review of post-operative specimen radiographs, and patient demographics. Results: A total of 297 RFID tags were placed, with 95.6% accurately positioned within the target range. The median target size was 29 mm, with the most common abnormalities being mass lesions (64%). Among the 13 inaccurately placed RFID tags (4.4%), all were identified preoperatively, with two requiring additional wire placements. RFID tags were successfully identified in 92% of specimen radiographs, and 8% of patients required re-excision due to positive or close margins. Notably, patients with multiple RFID tags showed a higher incidence of re-excision. Conclusions: The LOCalizer™ RFID system demonstrated a high accuracy rate for preoperative localization of breast lesions, presenting a viable alternative to WL. This technique improves surgical scheduling flexibility and enhances patient comfort. Comparative studies with other wire-free localization technologies, such as magnetic seeds and radar reflectors, are needed to determine the optimal approach for clinical practice.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信