{"title":"基于深度学习的三维脑体积MRI重建:定性和定量评估。","authors":"Yeseul Kang, Sang-Young Kim, Jun Hwee Kim, Nak-Hoon Son, Chae Jung Park","doi":"10.1186/s12880-025-01647-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To evaluate the performance of a deep learning reconstruction (DLR) based on Adaptive-Compressed sensing (CS)-Network for brain MRI and validate it in a clinical setting.</p><p><strong>Methods: </strong>Ten healthy volunteers and 22 consecutive patients were prospectively enrolled. Volunteers underwent 3D brain MRI including T1 without CS factor (9:16 min, reference standard); with CS factor of 2 without DLR (CS2, 4:6 min); with CS factor of 2 with DLR (DLR-CS2); with CS factor of 4 without DLR (CS4, 2:6 min); and with CS factor of 4 with DLR (DLR-CS4). The patients' MRI included the CS2 and DLR-CS4. The volumes of lateral ventricles, hippocampus, choroid plexus, and white matter hypointensity were calculated and compared among the sequences. Three radiologists independently assessed anatomical conspicuity, overall image quality, artifacts, signal-to-noise ratio (SNR), and sharpness using a 5-point scale for each sequence.</p><p><strong>Results: </strong>Applying acceleration factors of 2 and 4 reduced the scan time to 65.4% and 33.5%, respectively, of that of the reference standard. Volumes of all the measured subregions showed no significant differences among different sequences in all participants. In qualitative analysis, the interrater agreement was excellent (κ = 0.844-0.926). In volunteers, quality of DLR-CS4 were comparable to those of CS2 for all metrics except for the overall image quality and SNR despite a 51.2% scan time reduction. In patients, DLR-CS4 showed quality comparable to that of CS2 for all metrics.</p><p><strong>Conclusions: </strong>DLR allowed the scan time reduction by at least half without sacrificing image quality and volumetric quantification accuracy, supporting its reliability and efficiency.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"25 1","pages":"102"},"PeriodicalIF":2.9000,"publicationDate":"2025-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11951731/pdf/","citationCount":"0","resultStr":"{\"title\":\"Deep learning-based reconstruction for three-dimensional volumetric brain MRI: a qualitative and quantitative assessment.\",\"authors\":\"Yeseul Kang, Sang-Young Kim, Jun Hwee Kim, Nak-Hoon Son, Chae Jung Park\",\"doi\":\"10.1186/s12880-025-01647-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To evaluate the performance of a deep learning reconstruction (DLR) based on Adaptive-Compressed sensing (CS)-Network for brain MRI and validate it in a clinical setting.</p><p><strong>Methods: </strong>Ten healthy volunteers and 22 consecutive patients were prospectively enrolled. Volunteers underwent 3D brain MRI including T1 without CS factor (9:16 min, reference standard); with CS factor of 2 without DLR (CS2, 4:6 min); with CS factor of 2 with DLR (DLR-CS2); with CS factor of 4 without DLR (CS4, 2:6 min); and with CS factor of 4 with DLR (DLR-CS4). The patients' MRI included the CS2 and DLR-CS4. The volumes of lateral ventricles, hippocampus, choroid plexus, and white matter hypointensity were calculated and compared among the sequences. Three radiologists independently assessed anatomical conspicuity, overall image quality, artifacts, signal-to-noise ratio (SNR), and sharpness using a 5-point scale for each sequence.</p><p><strong>Results: </strong>Applying acceleration factors of 2 and 4 reduced the scan time to 65.4% and 33.5%, respectively, of that of the reference standard. Volumes of all the measured subregions showed no significant differences among different sequences in all participants. In qualitative analysis, the interrater agreement was excellent (κ = 0.844-0.926). In volunteers, quality of DLR-CS4 were comparable to those of CS2 for all metrics except for the overall image quality and SNR despite a 51.2% scan time reduction. In patients, DLR-CS4 showed quality comparable to that of CS2 for all metrics.</p><p><strong>Conclusions: </strong>DLR allowed the scan time reduction by at least half without sacrificing image quality and volumetric quantification accuracy, supporting its reliability and efficiency.</p>\",\"PeriodicalId\":9020,\"journal\":{\"name\":\"BMC Medical Imaging\",\"volume\":\"25 1\",\"pages\":\"102\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-03-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11951731/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Medical Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12880-025-01647-8\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-025-01647-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:评估基于自适应压缩感知(CS)网络的脑MRI深度学习重建(DLR)的性能,并在临床环境中进行验证。方法:前瞻性纳入10名健康志愿者和22名连续患者。志愿者行三维脑MRI,包括T1,无CS因素(9:16 min,参考标准);无DLR的CS因子为2 (CS2, 4:6 min);与DLR (DLR- cs2)的CS因子为2;无DLR的CS因子为4 (CS4, 2:6 min);DLR的CS因子为4 (DLR- cs4)。患者MRI包括CS2和DLR-CS4。计算各序列侧脑室、海马、脉络膜丛和白质低密度的体积并进行比较。三位放射科医生独立评估解剖显著性、整体图像质量、伪影、信噪比(SNR)和清晰度,采用5分制对每个序列进行评估。结果:采用2和4的加速因子,扫描时间分别缩短至参比标准的65.4%和33.5%。在所有参与者中,所有测量的子区域的体积在不同序列之间没有显着差异。在定性分析中,判据一致性极好(κ = 0.844 ~ 0.926)。在志愿者中,DLR-CS4的质量与CS2的质量相当,除了整体图像质量和信噪比,尽管扫描时间减少了51.2%。在患者中,DLR-CS4在所有指标上显示出与CS2相当的质量。结论:DLR在不牺牲图像质量和体积定量精度的情况下,使扫描时间减少至少一半,支持其可靠性和效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Deep learning-based reconstruction for three-dimensional volumetric brain MRI: a qualitative and quantitative assessment.

Background: To evaluate the performance of a deep learning reconstruction (DLR) based on Adaptive-Compressed sensing (CS)-Network for brain MRI and validate it in a clinical setting.

Methods: Ten healthy volunteers and 22 consecutive patients were prospectively enrolled. Volunteers underwent 3D brain MRI including T1 without CS factor (9:16 min, reference standard); with CS factor of 2 without DLR (CS2, 4:6 min); with CS factor of 2 with DLR (DLR-CS2); with CS factor of 4 without DLR (CS4, 2:6 min); and with CS factor of 4 with DLR (DLR-CS4). The patients' MRI included the CS2 and DLR-CS4. The volumes of lateral ventricles, hippocampus, choroid plexus, and white matter hypointensity were calculated and compared among the sequences. Three radiologists independently assessed anatomical conspicuity, overall image quality, artifacts, signal-to-noise ratio (SNR), and sharpness using a 5-point scale for each sequence.

Results: Applying acceleration factors of 2 and 4 reduced the scan time to 65.4% and 33.5%, respectively, of that of the reference standard. Volumes of all the measured subregions showed no significant differences among different sequences in all participants. In qualitative analysis, the interrater agreement was excellent (κ = 0.844-0.926). In volunteers, quality of DLR-CS4 were comparable to those of CS2 for all metrics except for the overall image quality and SNR despite a 51.2% scan time reduction. In patients, DLR-CS4 showed quality comparable to that of CS2 for all metrics.

Conclusions: DLR allowed the scan time reduction by at least half without sacrificing image quality and volumetric quantification accuracy, supporting its reliability and efficiency.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信