{"title":"核医学屏蔽计算中非点源效应的系统理论研究。","authors":"Tianliang Gu","doi":"10.1097/HP.0000000000001930","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>The objective of this note was to systematically study the effects from nonpoint radiation sources on the nuclear medicine imaging room or uptake room shielding design. The dose from a nonpoint source to a location at a certain distance to the center of the source was calculated. A correction factor could be applied to the dose calculated using a point source model with the same distance to compensate the nonpoint source effects. The correction factor was a function only depending on the source relative dimension, the ratio of the source's geometric dimension to the distance. Theoretical and numerical calculation were performed to calculate the correction factor on a one-dimensional line source, two-dimensional circular disc source, three-dimensional sphere, and cylinder sources. Our study indicated that for large nuclear medicine imaging rooms, the point source model was a good approximation for shielding design. For a small uptake room, a nonpoint source correction may be considered to calculate the barrier thickness.</p>","PeriodicalId":12976,"journal":{"name":"Health physics","volume":"128 5","pages":"413-419"},"PeriodicalIF":1.4000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Systematical Theoretical Study of the Nonpoint Source Effects in Nuclear Medicine Shielding Calculation.\",\"authors\":\"Tianliang Gu\",\"doi\":\"10.1097/HP.0000000000001930\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>The objective of this note was to systematically study the effects from nonpoint radiation sources on the nuclear medicine imaging room or uptake room shielding design. The dose from a nonpoint source to a location at a certain distance to the center of the source was calculated. A correction factor could be applied to the dose calculated using a point source model with the same distance to compensate the nonpoint source effects. The correction factor was a function only depending on the source relative dimension, the ratio of the source's geometric dimension to the distance. Theoretical and numerical calculation were performed to calculate the correction factor on a one-dimensional line source, two-dimensional circular disc source, three-dimensional sphere, and cylinder sources. Our study indicated that for large nuclear medicine imaging rooms, the point source model was a good approximation for shielding design. For a small uptake room, a nonpoint source correction may be considered to calculate the barrier thickness.</p>\",\"PeriodicalId\":12976,\"journal\":{\"name\":\"Health physics\",\"volume\":\"128 5\",\"pages\":\"413-419\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Health physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/HP.0000000000001930\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HP.0000000000001930","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Systematical Theoretical Study of the Nonpoint Source Effects in Nuclear Medicine Shielding Calculation.
Abstract: The objective of this note was to systematically study the effects from nonpoint radiation sources on the nuclear medicine imaging room or uptake room shielding design. The dose from a nonpoint source to a location at a certain distance to the center of the source was calculated. A correction factor could be applied to the dose calculated using a point source model with the same distance to compensate the nonpoint source effects. The correction factor was a function only depending on the source relative dimension, the ratio of the source's geometric dimension to the distance. Theoretical and numerical calculation were performed to calculate the correction factor on a one-dimensional line source, two-dimensional circular disc source, three-dimensional sphere, and cylinder sources. Our study indicated that for large nuclear medicine imaging rooms, the point source model was a good approximation for shielding design. For a small uptake room, a nonpoint source correction may be considered to calculate the barrier thickness.
期刊介绍:
Health Physics, first published in 1958, provides the latest research to a wide variety of radiation safety professionals including health physicists, nuclear chemists, medical physicists, and radiation safety officers with interests in nuclear and radiation science. The Journal allows professionals in these and other disciplines in science and engineering to stay on the cutting edge of scientific and technological advances in the field of radiation safety. The Journal publishes original papers, technical notes, articles on advances in practical applications, editorials, and correspondence. Journal articles report on the latest findings in theoretical, practical, and applied disciplines of epidemiology and radiation effects, radiation biology and radiation science, radiation ecology, and related fields.