正畸微型种植体卫生方案对龈下细菌负荷的比较评价。

Q2 Medicine
Dental Press Journal of Orthodontics Pub Date : 2025-03-24 eCollection Date: 2025-01-01 DOI:10.1590/2177-6709.30.1.e2524108.oar
Amanda Osório Ayres de Freitas, Ana Paula Vieira Colombo, Celuta Sales Alviano, Daniela Sales Alviano, Renata Martins do Souto, Deborah Catharine de Assis Leite, Isabela Lopes Vale Pedrosa Lima, Matilde da Cunha Gonçalves Nojima
{"title":"正畸微型种植体卫生方案对龈下细菌负荷的比较评价。","authors":"Amanda Osório Ayres de Freitas, Ana Paula Vieira Colombo, Celuta Sales Alviano, Daniela Sales Alviano, Renata Martins do Souto, Deborah Catharine de Assis Leite, Isabela Lopes Vale Pedrosa Lima, Matilde da Cunha Gonçalves Nojima","doi":"10.1590/2177-6709.30.1.e2524108.oar","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of this study was to evaluate the effectiveness of four hygiene protocols for orthodontic mini-implants in reducing the subgingival bacterial load in the peri-implant sulcus.</p><p><strong>Methods: </strong>Thirty-nine healthy individuals who had fifty-nine as-received mini-implants (20 men, 19 women, 20 to 42 years old) were randomly distributed into four groups of hygiene protocols: mechanical hygiene (M); mechanical hygiene associated with 0.12% digluconate chlorhexidine (CHX), 0.03% triclosan (T), or 0.05% cetylpyridinium chloride (CP). All individuals were instructed regarding the hygiene procedures (T0). For bacterial load analysis, the gingival crevicular fluid from peri-implant sulcus was collected and submitted to quantitative real-time PCR at baseline (T1) and after 21 days following the hygiene protocols (T2). Wilcoxon test was applied for intergroup comparisons, whereas differences among groups at each time point were examined by Kruskal-Wallis test. The significance level was 5%.</p><p><strong>Results: </strong>Significant difference was detected between baseline and post-protocol times for bacterial total counts, comparing intergroup results, except for mechanical hygiene associated with cetylpyridinium chloride (M p=0.018, CHX p=0.028, T p=0.012, CP p=0.065). No significant difference was detected among the evaluated methods (p=0.181).</p><p><strong>Conclusions: </strong>The mechanical hygiene of orthodontic mini-implants itself was capable to reduce total bacteria load and keep devices clean. Commonly, orthodontists prescribe, in addition to mechanical biofilm removal, some protocols combining adjunctive chemical agents as chlorhexidine. The authors believe that results have large importance for dental community, as they can protect patients from overtreatment.</p>","PeriodicalId":38720,"journal":{"name":"Dental Press Journal of Orthodontics","volume":"30 1","pages":"e2524108"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11939425/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparative evaluation of orthodontic mini-implants hygiene protocols on subgingival bacterial load.\",\"authors\":\"Amanda Osório Ayres de Freitas, Ana Paula Vieira Colombo, Celuta Sales Alviano, Daniela Sales Alviano, Renata Martins do Souto, Deborah Catharine de Assis Leite, Isabela Lopes Vale Pedrosa Lima, Matilde da Cunha Gonçalves Nojima\",\"doi\":\"10.1590/2177-6709.30.1.e2524108.oar\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The aim of this study was to evaluate the effectiveness of four hygiene protocols for orthodontic mini-implants in reducing the subgingival bacterial load in the peri-implant sulcus.</p><p><strong>Methods: </strong>Thirty-nine healthy individuals who had fifty-nine as-received mini-implants (20 men, 19 women, 20 to 42 years old) were randomly distributed into four groups of hygiene protocols: mechanical hygiene (M); mechanical hygiene associated with 0.12% digluconate chlorhexidine (CHX), 0.03% triclosan (T), or 0.05% cetylpyridinium chloride (CP). All individuals were instructed regarding the hygiene procedures (T0). For bacterial load analysis, the gingival crevicular fluid from peri-implant sulcus was collected and submitted to quantitative real-time PCR at baseline (T1) and after 21 days following the hygiene protocols (T2). Wilcoxon test was applied for intergroup comparisons, whereas differences among groups at each time point were examined by Kruskal-Wallis test. The significance level was 5%.</p><p><strong>Results: </strong>Significant difference was detected between baseline and post-protocol times for bacterial total counts, comparing intergroup results, except for mechanical hygiene associated with cetylpyridinium chloride (M p=0.018, CHX p=0.028, T p=0.012, CP p=0.065). No significant difference was detected among the evaluated methods (p=0.181).</p><p><strong>Conclusions: </strong>The mechanical hygiene of orthodontic mini-implants itself was capable to reduce total bacteria load and keep devices clean. Commonly, orthodontists prescribe, in addition to mechanical biofilm removal, some protocols combining adjunctive chemical agents as chlorhexidine. The authors believe that results have large importance for dental community, as they can protect patients from overtreatment.</p>\",\"PeriodicalId\":38720,\"journal\":{\"name\":\"Dental Press Journal of Orthodontics\",\"volume\":\"30 1\",\"pages\":\"e2524108\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11939425/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Press Journal of Orthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/2177-6709.30.1.e2524108.oar\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Press Journal of Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/2177-6709.30.1.e2524108.oar","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是评估正畸微型种植体的四种卫生方案在减少种植体周围沟龈下细菌负荷方面的有效性。方法:39名接受了59个微型植入物的健康个体(20名男性,19名女性,20 ~ 42岁)随机分为四组卫生方案:机械卫生(M);机械卫生与0.12%二光酸氯己定(CHX), 0.03%三氯生(T)或0.05%十六烷基氯吡啶(CP)相关。所有人都接受了卫生程序的指导(T0)。为了进行细菌负荷分析,在基线(T1)和卫生方案21天后(T2)收集种植体周围沟龈沟液并提交定量实时PCR。组间比较采用Wilcoxon检验,各组间各时间点差异采用Kruskal-Wallis检验。显著性水平为5%。结果:除了与氯化十六烷基吡啶相关的机械卫生(M p=0.018, CHX p=0.028, T p=0.012, CP p=0.065)外,各组间比较,基线时间和方案后时间的细菌总数有显著差异。各评价方法间差异无统计学意义(p=0.181)。结论:正畸微型种植体本身的机械卫生能够减少细菌总负荷,保持器械清洁。通常,除了机械去除生物膜外,正畸医生还会开出一些结合氯己定等辅助化学剂的方案。作者认为,这一结果对牙科界具有重要意义,因为它们可以保护患者免受过度治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative evaluation of orthodontic mini-implants hygiene protocols on subgingival bacterial load.

Objective: The aim of this study was to evaluate the effectiveness of four hygiene protocols for orthodontic mini-implants in reducing the subgingival bacterial load in the peri-implant sulcus.

Methods: Thirty-nine healthy individuals who had fifty-nine as-received mini-implants (20 men, 19 women, 20 to 42 years old) were randomly distributed into four groups of hygiene protocols: mechanical hygiene (M); mechanical hygiene associated with 0.12% digluconate chlorhexidine (CHX), 0.03% triclosan (T), or 0.05% cetylpyridinium chloride (CP). All individuals were instructed regarding the hygiene procedures (T0). For bacterial load analysis, the gingival crevicular fluid from peri-implant sulcus was collected and submitted to quantitative real-time PCR at baseline (T1) and after 21 days following the hygiene protocols (T2). Wilcoxon test was applied for intergroup comparisons, whereas differences among groups at each time point were examined by Kruskal-Wallis test. The significance level was 5%.

Results: Significant difference was detected between baseline and post-protocol times for bacterial total counts, comparing intergroup results, except for mechanical hygiene associated with cetylpyridinium chloride (M p=0.018, CHX p=0.028, T p=0.012, CP p=0.065). No significant difference was detected among the evaluated methods (p=0.181).

Conclusions: The mechanical hygiene of orthodontic mini-implants itself was capable to reduce total bacteria load and keep devices clean. Commonly, orthodontists prescribe, in addition to mechanical biofilm removal, some protocols combining adjunctive chemical agents as chlorhexidine. The authors believe that results have large importance for dental community, as they can protect patients from overtreatment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dental Press Journal of Orthodontics
Dental Press Journal of Orthodontics Dentistry-Orthodontics
CiteScore
2.00
自引率
0.00%
发文量
40
审稿时长
27 weeks
期刊介绍: The Dental Press Journal of Orthodontics publishes scientific research articles, significant reviews, clinical and technical case reports, brief communications, and other materials related to Orthodontics and Facial Orthopedics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信