{"title":"利用偏振敏感前段光学相干断层扫描评估虹膜色素上皮去极化及其相关因素。","authors":"Xiaoling Li, Risa Higashita, Lingxi Hu, Bing Yang, Zunjie Xiao, Masahiro Yamanari, Jiang Liu","doi":"10.1007/s10792-025-03473-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the distribution of depolarization and its association with demographic and ocular biometric factors, we used polarization-sensitive anterior segment optical coherence tomography (PS-AS-OCT), to investigate the characteristics of the iris pigment epithelium (IPE) in healthy eyes.</p><p><strong>Method: </strong>A group of 105 healthy Japanese adults participated in this study, and PS-AS-OCT images were captured for both eyes. The IPE depolarization region was segmented from the horizontal scan of the left eye images. The measurement of depolarization was determined by assessing two parameters: the height of the IPE depolarization region in the grayscale entropy image and the melanin concentration rate in the color entropy image. To investigate the distribution of depolarization, the segmented region was evenly divided into 99 fractions. This division was then evaluated at various locations within the IPE depolarization region using the depolarization parameters. Subsequantly, we analyzed the values obtained in relation to demographic and ocular biometric factors. Such factors include age, gender, axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), and lens thickness (LT).</p><p><strong>Results: </strong>A total of 105 patients (age 39 ± 11yrs) fulfilled the inclusion criteria, including 84 males and 21 females. The height of the IPE depolarization region increased in both the pupillary and peripheral regions, while it remained stable in the midzone region. The distribution of melanin concentration rate exhibited a smooth pattern, with a decrease observed only in the periphery. Furthermore, the height of IPE depolarization in the peripheral region was found to be negatively correlated with AL and ACD, but positively correlated with LT, while the melanin concentration rate of specific points in mid-peripheral region was negatively correlated with AL (P < 0.05).</p><p><strong>Conclusion: </strong>By observing the distribution of IPE melanin-related depolarization in vivo though PS-AS-OCT, we identified the association between depolarization parameters and biometric factors AL, ACD and LT. This comprehensive baseline of the IPE depolarization parameters in healthy Japanese adults may offer valuable insights, especially in the context of pathological conditions.</p>","PeriodicalId":14473,"journal":{"name":"International Ophthalmology","volume":"45 1","pages":"122"},"PeriodicalIF":1.4000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of iris pigment epithelium depolarization and associated factors using polarization-sensitive anterior segment optical coherence tomography.\",\"authors\":\"Xiaoling Li, Risa Higashita, Lingxi Hu, Bing Yang, Zunjie Xiao, Masahiro Yamanari, Jiang Liu\",\"doi\":\"10.1007/s10792-025-03473-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the distribution of depolarization and its association with demographic and ocular biometric factors, we used polarization-sensitive anterior segment optical coherence tomography (PS-AS-OCT), to investigate the characteristics of the iris pigment epithelium (IPE) in healthy eyes.</p><p><strong>Method: </strong>A group of 105 healthy Japanese adults participated in this study, and PS-AS-OCT images were captured for both eyes. The IPE depolarization region was segmented from the horizontal scan of the left eye images. The measurement of depolarization was determined by assessing two parameters: the height of the IPE depolarization region in the grayscale entropy image and the melanin concentration rate in the color entropy image. To investigate the distribution of depolarization, the segmented region was evenly divided into 99 fractions. This division was then evaluated at various locations within the IPE depolarization region using the depolarization parameters. Subsequantly, we analyzed the values obtained in relation to demographic and ocular biometric factors. Such factors include age, gender, axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), and lens thickness (LT).</p><p><strong>Results: </strong>A total of 105 patients (age 39 ± 11yrs) fulfilled the inclusion criteria, including 84 males and 21 females. The height of the IPE depolarization region increased in both the pupillary and peripheral regions, while it remained stable in the midzone region. The distribution of melanin concentration rate exhibited a smooth pattern, with a decrease observed only in the periphery. Furthermore, the height of IPE depolarization in the peripheral region was found to be negatively correlated with AL and ACD, but positively correlated with LT, while the melanin concentration rate of specific points in mid-peripheral region was negatively correlated with AL (P < 0.05).</p><p><strong>Conclusion: </strong>By observing the distribution of IPE melanin-related depolarization in vivo though PS-AS-OCT, we identified the association between depolarization parameters and biometric factors AL, ACD and LT. This comprehensive baseline of the IPE depolarization parameters in healthy Japanese adults may offer valuable insights, especially in the context of pathological conditions.</p>\",\"PeriodicalId\":14473,\"journal\":{\"name\":\"International Ophthalmology\",\"volume\":\"45 1\",\"pages\":\"122\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10792-025-03473-x\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10792-025-03473-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:利用偏振敏感前段光学相干断层扫描(PS-AS-OCT)研究健康眼睛虹膜色素上皮(IPE)的特征,以评估去偏振的分布及其与人口统计学和眼部生物特征的关系。方法:选取105名日本健康成人为研究对象,采集双眼PS-AS-OCT图像。从左眼水平扫描图像中分割出IPE去极化区域。通过评估灰度熵图像中IPE去极化区域的高度和颜色熵图像中的黑色素浓度率两个参数来确定去极化的测量。为了研究去极化的分布,将分割的区域均匀分成99个分数。然后使用去极化参数在IPE去极化区域内的不同位置评估这种划分。随后,我们分析了与人口统计学和眼部生物特征因素相关的数值。这些因素包括年龄、性别、眼轴长度(AL)、前房深度(ACD)、角膜中央厚度(CCT)和晶状体厚度(LT)。结果:符合纳入标准的患者105例(年龄39±11岁),其中男性84例,女性21例。瞳孔和周边区域的IPE去极化区高度均呈上升趋势,而中部区域的IPE去极化区高度保持稳定。黑素浓度率呈平稳分布,仅外周呈下降趋势。外周区IPE去极化高度与AL、ACD呈负相关,与LT呈正相关,而外周区中特定点黑色素浓度率与AL呈负相关(P)。通过PS-AS-OCT观察IPE黑色素相关去极化在体内的分布,我们确定了去极化参数与生物特征因子AL、ACD和lt之间的关联。这一健康日本成年人IPE去极化参数的综合基线可能提供有价值的见解,特别是在病理条件下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of iris pigment epithelium depolarization and associated factors using polarization-sensitive anterior segment optical coherence tomography.

Purpose: To assess the distribution of depolarization and its association with demographic and ocular biometric factors, we used polarization-sensitive anterior segment optical coherence tomography (PS-AS-OCT), to investigate the characteristics of the iris pigment epithelium (IPE) in healthy eyes.

Method: A group of 105 healthy Japanese adults participated in this study, and PS-AS-OCT images were captured for both eyes. The IPE depolarization region was segmented from the horizontal scan of the left eye images. The measurement of depolarization was determined by assessing two parameters: the height of the IPE depolarization region in the grayscale entropy image and the melanin concentration rate in the color entropy image. To investigate the distribution of depolarization, the segmented region was evenly divided into 99 fractions. This division was then evaluated at various locations within the IPE depolarization region using the depolarization parameters. Subsequantly, we analyzed the values obtained in relation to demographic and ocular biometric factors. Such factors include age, gender, axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), and lens thickness (LT).

Results: A total of 105 patients (age 39 ± 11yrs) fulfilled the inclusion criteria, including 84 males and 21 females. The height of the IPE depolarization region increased in both the pupillary and peripheral regions, while it remained stable in the midzone region. The distribution of melanin concentration rate exhibited a smooth pattern, with a decrease observed only in the periphery. Furthermore, the height of IPE depolarization in the peripheral region was found to be negatively correlated with AL and ACD, but positively correlated with LT, while the melanin concentration rate of specific points in mid-peripheral region was negatively correlated with AL (P < 0.05).

Conclusion: By observing the distribution of IPE melanin-related depolarization in vivo though PS-AS-OCT, we identified the association between depolarization parameters and biometric factors AL, ACD and LT. This comprehensive baseline of the IPE depolarization parameters in healthy Japanese adults may offer valuable insights, especially in the context of pathological conditions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
451
期刊介绍: International Ophthalmology provides the clinician with articles on all the relevant subspecialties of ophthalmology, with a broad international scope. The emphasis is on presentation of the latest clinical research in the field. In addition, the journal includes regular sections devoted to new developments in technologies, products, and techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信