使用功能模型界面的儿科心血管多尺度建模。

IF 1.6 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Ellen E Garven, Ethan Kung, Randy M Stevens, Amy L Throckmorton
{"title":"使用功能模型界面的儿科心血管多尺度建模。","authors":"Ellen E Garven, Ethan Kung, Randy M Stevens, Amy L Throckmorton","doi":"10.1007/s13239-024-00767-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Computational models of the cardiovascular system continue to increase in complexity. As more elements of the physiology are captured in multiscale models, there is a need to efficiently integrate subsystems. The objective of this study is to demonstrate the effectiveness of a coupling methodology, called functional mock-up interface (FMI), as applied to multiscale cardiovascular modeling.</p><p><strong>Methods: </strong>The multiscale model is composed of two subsystems: a computational fluid dynamics (CFD) model coupled to a lumped parameter model (LPM). The LPM is packaged using the FMI standard and imported into the CFD subsystem using an FMI co-simulation architecture. The functionality of an FMI coupling was demonstrated in a univentricular parallel circulation by means of compatible tools, including ANSYS CFX and Python. Predicted pressures and flows were evaluated in comparison with clinical data and a previously developed computational model.</p><p><strong>Results: </strong>The two models exchanged pressure and flow data between their boundaries at each timestep, demonstrating sufficient inter-subsystem communication. The models recreated pressures and flows from clinical measurements and a patient-specific model previously published.</p><p><strong>Conclusion: </strong>FMI integrated with ANSYS CFX is an effective approach for interfacing cardiovascular multiscale models as demonstrated by the presented univentricular circulatory model. FMI offers a modular approach towards tool integration and is an advantageous strategy for modeling complex systems.</p>","PeriodicalId":54322,"journal":{"name":"Cardiovascular Engineering and Technology","volume":"16 2","pages":"202-210"},"PeriodicalIF":1.6000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11933148/pdf/","citationCount":"0","resultStr":"{\"title\":\"Pediatric Cardiovascular Multiscale Modeling using a Functional Mock-up Interface.\",\"authors\":\"Ellen E Garven, Ethan Kung, Randy M Stevens, Amy L Throckmorton\",\"doi\":\"10.1007/s13239-024-00767-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Computational models of the cardiovascular system continue to increase in complexity. As more elements of the physiology are captured in multiscale models, there is a need to efficiently integrate subsystems. The objective of this study is to demonstrate the effectiveness of a coupling methodology, called functional mock-up interface (FMI), as applied to multiscale cardiovascular modeling.</p><p><strong>Methods: </strong>The multiscale model is composed of two subsystems: a computational fluid dynamics (CFD) model coupled to a lumped parameter model (LPM). The LPM is packaged using the FMI standard and imported into the CFD subsystem using an FMI co-simulation architecture. The functionality of an FMI coupling was demonstrated in a univentricular parallel circulation by means of compatible tools, including ANSYS CFX and Python. Predicted pressures and flows were evaluated in comparison with clinical data and a previously developed computational model.</p><p><strong>Results: </strong>The two models exchanged pressure and flow data between their boundaries at each timestep, demonstrating sufficient inter-subsystem communication. The models recreated pressures and flows from clinical measurements and a patient-specific model previously published.</p><p><strong>Conclusion: </strong>FMI integrated with ANSYS CFX is an effective approach for interfacing cardiovascular multiscale models as demonstrated by the presented univentricular circulatory model. FMI offers a modular approach towards tool integration and is an advantageous strategy for modeling complex systems.</p>\",\"PeriodicalId\":54322,\"journal\":{\"name\":\"Cardiovascular Engineering and Technology\",\"volume\":\"16 2\",\"pages\":\"202-210\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11933148/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Engineering and Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s13239-024-00767-6\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Engineering and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s13239-024-00767-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的:心血管系统的计算模型的复杂性不断增加。随着越来越多的生理要素被捕获到多尺度模型中,需要有效地整合子系统。本研究的目的是证明一种耦合方法的有效性,称为功能模型接口(FMI),应用于多尺度心血管建模。方法:多尺度模型由计算流体动力学(CFD)模型和集总参数模型(LPM)两个子系统组成。LPM使用FMI标准进行打包,并使用FMI联合仿真体系结构导入CFD子系统。通过ANSYS CFX和Python等兼容工具,在单心室并联循环中验证了FMI耦合的功能。将预测的压力和流量与临床数据和先前开发的计算模型进行比较。结果:两个模型在每个时间步在其边界之间交换压力和流量数据,显示出充分的子系统间通信。这些模型从临床测量和先前发表的患者特定模型中重现了压力和流量。结论:FMI集成ANSYS CFX是一种有效的心血管多尺度模型连接方法,所建立的单心室循环模型证明了这一点。FMI为工具集成提供了一种模块化方法,是对复杂系统建模的一种有利策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pediatric Cardiovascular Multiscale Modeling using a Functional Mock-up Interface.

Purpose: Computational models of the cardiovascular system continue to increase in complexity. As more elements of the physiology are captured in multiscale models, there is a need to efficiently integrate subsystems. The objective of this study is to demonstrate the effectiveness of a coupling methodology, called functional mock-up interface (FMI), as applied to multiscale cardiovascular modeling.

Methods: The multiscale model is composed of two subsystems: a computational fluid dynamics (CFD) model coupled to a lumped parameter model (LPM). The LPM is packaged using the FMI standard and imported into the CFD subsystem using an FMI co-simulation architecture. The functionality of an FMI coupling was demonstrated in a univentricular parallel circulation by means of compatible tools, including ANSYS CFX and Python. Predicted pressures and flows were evaluated in comparison with clinical data and a previously developed computational model.

Results: The two models exchanged pressure and flow data between their boundaries at each timestep, demonstrating sufficient inter-subsystem communication. The models recreated pressures and flows from clinical measurements and a patient-specific model previously published.

Conclusion: FMI integrated with ANSYS CFX is an effective approach for interfacing cardiovascular multiscale models as demonstrated by the presented univentricular circulatory model. FMI offers a modular approach towards tool integration and is an advantageous strategy for modeling complex systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiovascular Engineering and Technology
Cardiovascular Engineering and Technology Engineering-Biomedical Engineering
CiteScore
4.00
自引率
0.00%
发文量
51
期刊介绍: Cardiovascular Engineering and Technology is a journal publishing the spectrum of basic to translational research in all aspects of cardiovascular physiology and medical treatment. It is the forum for academic and industrial investigators to disseminate research that utilizes engineering principles and methods to advance fundamental knowledge and technological solutions related to the cardiovascular system. Manuscripts spanning from subcellular to systems level topics are invited, including but not limited to implantable medical devices, hemodynamics and tissue biomechanics, functional imaging, surgical devices, electrophysiology, tissue engineering and regenerative medicine, diagnostic instruments, transport and delivery of biologics, and sensors. In addition to manuscripts describing the original publication of research, manuscripts reviewing developments in these topics or their state-of-art are also invited.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信