Hien Van Vo, Quynh Van Nguyen, Anh Ngoc Le, Tri Thi Bui
{"title":"超声心排血量监测评价严重烧伤患者在烧伤创面切除和植皮过程中的血流动力学变化:一项前瞻性观察研究。","authors":"Hien Van Vo, Quynh Van Nguyen, Anh Ngoc Le, Tri Thi Bui","doi":"10.62347/JNWH4046","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate changes in hemodynamic parameters using the Ultrasound Cardiac Output Monitoring (USCOM) method during general anesthesia for burn wound excision and skin grafting surgery in patients with severe burns.</p><p><strong>Methods: </strong>This prospective observational study included 40 severe burn patients, aged 18-60 years, treated at the Intensive Care Unit (ICU) of Le Huu Trac National Burn Hospital (Hanoi, Vietnam). All patients underwent burn wound excision and skin grafting between June 2023 and March 2024.</p><p><strong>Results: </strong>The average heart rate (HR) at the study time points ranged from 116.8 to 124.3 beats/min. The differences in HR at T<sub>1</sub>, T<sub>2</sub>, T<sub>3</sub>, T<sub>5</sub>, and T<sub>6</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05). Mean arterial pressure (MAP) at the study time points ranged from 73.8 mmHg to 95.68 mmHg. The differences in MAP at T<sub>1</sub>, T<sub>2</sub>, T<sub>3</sub>, T<sub>4</sub>, and T<sub>5</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05). Cardiac Output (CO) and Cardiac Index (CI) values at all study time points were within normal ranges (6-7.04 l/min and 3.66-4.33 l/min/m<sup>2</sup>, respectively). CO and CI were highest at T<sub>0</sub> (7.04 l/min; 4.33 l/min/m<sup>2</sup>) and lowest at T<sub>1</sub> (6 l/min; 3.66 l/min/m<sup>2</sup>). The differences in CO and CI at T<sub>1</sub>, T<sub>2</sub>, T<sub>4</sub>, T<sub>5</sub>, and T<sub>6</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05). Stroke Volume (SV) and Stroke Volume Index (SVI) values at all time points were within normal ranges (51.2-56.75 ml and 30.93-34.53 ml/m<sup>2</sup>). The differences in SV and SVI at T<sub>1</sub>, T<sub>4</sub>, and T<sub>5</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05). Systemic Vascular Resistance (SVR) and Systemic Vascular Resistance Index (SVRI) values at all time points were within normal ranges (1006.03-1240.45 d.s.cm<sup>-5</sup> and 1681.98-2060.4 d.s.cm<sup>-5</sup>.m<sup>2</sup>). SVR and SVRI were highest at T<sub>6</sub> (1240.45 d.s.cm<sup>-5</sup> and 2060.4 d.s.cm<sup>-5</sup>.m<sup>2</sup>) and lowest at T<sub>1</sub> (1006.03 d.s.cm<sup>-5</sup> and 1681.98 d.s.cm<sup>-5</sup>.m<sup>2</sup>). The differences in SVR and SVRI at T<sub>1</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05).</p><p><strong>Conclusion: </strong>The study demonstrated that hemodynamic parameters, including CO, CI, SV, SVI, SVR, and SVRI, remained within normal ranges throughout the anesthesia process. However, heart rate and blood pressure tended to be elevated, reflecting the hemodynamic characteristics of burn patients. This underscores the importance of close monitoring and adaptive management during anesthesia and resuscitation to ensure hemodynamic stability tailored to the characteristics of severe burn patients.</p>","PeriodicalId":45488,"journal":{"name":"International Journal of Burns and Trauma","volume":"15 1","pages":"1-10"},"PeriodicalIF":1.4000,"publicationDate":"2025-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11929015/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of hemodynamic changes with ultrasound cardiac output monitoring during burn wound excision and skin grafting in severely burned patients: a prospective observational study.\",\"authors\":\"Hien Van Vo, Quynh Van Nguyen, Anh Ngoc Le, Tri Thi Bui\",\"doi\":\"10.62347/JNWH4046\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate changes in hemodynamic parameters using the Ultrasound Cardiac Output Monitoring (USCOM) method during general anesthesia for burn wound excision and skin grafting surgery in patients with severe burns.</p><p><strong>Methods: </strong>This prospective observational study included 40 severe burn patients, aged 18-60 years, treated at the Intensive Care Unit (ICU) of Le Huu Trac National Burn Hospital (Hanoi, Vietnam). All patients underwent burn wound excision and skin grafting between June 2023 and March 2024.</p><p><strong>Results: </strong>The average heart rate (HR) at the study time points ranged from 116.8 to 124.3 beats/min. The differences in HR at T<sub>1</sub>, T<sub>2</sub>, T<sub>3</sub>, T<sub>5</sub>, and T<sub>6</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05). Mean arterial pressure (MAP) at the study time points ranged from 73.8 mmHg to 95.68 mmHg. The differences in MAP at T<sub>1</sub>, T<sub>2</sub>, T<sub>3</sub>, T<sub>4</sub>, and T<sub>5</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05). Cardiac Output (CO) and Cardiac Index (CI) values at all study time points were within normal ranges (6-7.04 l/min and 3.66-4.33 l/min/m<sup>2</sup>, respectively). CO and CI were highest at T<sub>0</sub> (7.04 l/min; 4.33 l/min/m<sup>2</sup>) and lowest at T<sub>1</sub> (6 l/min; 3.66 l/min/m<sup>2</sup>). The differences in CO and CI at T<sub>1</sub>, T<sub>2</sub>, T<sub>4</sub>, T<sub>5</sub>, and T<sub>6</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05). Stroke Volume (SV) and Stroke Volume Index (SVI) values at all time points were within normal ranges (51.2-56.75 ml and 30.93-34.53 ml/m<sup>2</sup>). The differences in SV and SVI at T<sub>1</sub>, T<sub>4</sub>, and T<sub>5</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05). Systemic Vascular Resistance (SVR) and Systemic Vascular Resistance Index (SVRI) values at all time points were within normal ranges (1006.03-1240.45 d.s.cm<sup>-5</sup> and 1681.98-2060.4 d.s.cm<sup>-5</sup>.m<sup>2</sup>). SVR and SVRI were highest at T<sub>6</sub> (1240.45 d.s.cm<sup>-5</sup> and 2060.4 d.s.cm<sup>-5</sup>.m<sup>2</sup>) and lowest at T<sub>1</sub> (1006.03 d.s.cm<sup>-5</sup> and 1681.98 d.s.cm<sup>-5</sup>.m<sup>2</sup>). The differences in SVR and SVRI at T<sub>1</sub> compared to T<sub>0</sub> were statistically significant (P < 0.05).</p><p><strong>Conclusion: </strong>The study demonstrated that hemodynamic parameters, including CO, CI, SV, SVI, SVR, and SVRI, remained within normal ranges throughout the anesthesia process. However, heart rate and blood pressure tended to be elevated, reflecting the hemodynamic characteristics of burn patients. This underscores the importance of close monitoring and adaptive management during anesthesia and resuscitation to ensure hemodynamic stability tailored to the characteristics of severe burn patients.</p>\",\"PeriodicalId\":45488,\"journal\":{\"name\":\"International Journal of Burns and Trauma\",\"volume\":\"15 1\",\"pages\":\"1-10\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11929015/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Burns and Trauma\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.62347/JNWH4046\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Burns and Trauma","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.62347/JNWH4046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
Evaluation of hemodynamic changes with ultrasound cardiac output monitoring during burn wound excision and skin grafting in severely burned patients: a prospective observational study.
Objectives: To evaluate changes in hemodynamic parameters using the Ultrasound Cardiac Output Monitoring (USCOM) method during general anesthesia for burn wound excision and skin grafting surgery in patients with severe burns.
Methods: This prospective observational study included 40 severe burn patients, aged 18-60 years, treated at the Intensive Care Unit (ICU) of Le Huu Trac National Burn Hospital (Hanoi, Vietnam). All patients underwent burn wound excision and skin grafting between June 2023 and March 2024.
Results: The average heart rate (HR) at the study time points ranged from 116.8 to 124.3 beats/min. The differences in HR at T1, T2, T3, T5, and T6 compared to T0 were statistically significant (P < 0.05). Mean arterial pressure (MAP) at the study time points ranged from 73.8 mmHg to 95.68 mmHg. The differences in MAP at T1, T2, T3, T4, and T5 compared to T0 were statistically significant (P < 0.05). Cardiac Output (CO) and Cardiac Index (CI) values at all study time points were within normal ranges (6-7.04 l/min and 3.66-4.33 l/min/m2, respectively). CO and CI were highest at T0 (7.04 l/min; 4.33 l/min/m2) and lowest at T1 (6 l/min; 3.66 l/min/m2). The differences in CO and CI at T1, T2, T4, T5, and T6 compared to T0 were statistically significant (P < 0.05). Stroke Volume (SV) and Stroke Volume Index (SVI) values at all time points were within normal ranges (51.2-56.75 ml and 30.93-34.53 ml/m2). The differences in SV and SVI at T1, T4, and T5 compared to T0 were statistically significant (P < 0.05). Systemic Vascular Resistance (SVR) and Systemic Vascular Resistance Index (SVRI) values at all time points were within normal ranges (1006.03-1240.45 d.s.cm-5 and 1681.98-2060.4 d.s.cm-5.m2). SVR and SVRI were highest at T6 (1240.45 d.s.cm-5 and 2060.4 d.s.cm-5.m2) and lowest at T1 (1006.03 d.s.cm-5 and 1681.98 d.s.cm-5.m2). The differences in SVR and SVRI at T1 compared to T0 were statistically significant (P < 0.05).
Conclusion: The study demonstrated that hemodynamic parameters, including CO, CI, SV, SVI, SVR, and SVRI, remained within normal ranges throughout the anesthesia process. However, heart rate and blood pressure tended to be elevated, reflecting the hemodynamic characteristics of burn patients. This underscores the importance of close monitoring and adaptive management during anesthesia and resuscitation to ensure hemodynamic stability tailored to the characteristics of severe burn patients.