下肢和上肢注射搅拌生理盐水以识别卵圆孔未闭(LOCATE)。

IF 1.4 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Carmelo J Panetta, Les B Forgosh, Elizabeth Bisinov, Haitham Hussein, David Benditt, Benjamin Miller, Marat Yanavitski, Marit Thorsgard, Beth Jorgenson, Ganesh Raveendran, Nadeem Iqbal
{"title":"下肢和上肢注射搅拌生理盐水以识别卵圆孔未闭(LOCATE)。","authors":"Carmelo J Panetta, Les B Forgosh, Elizabeth Bisinov, Haitham Hussein, David Benditt, Benjamin Miller, Marat Yanavitski, Marit Thorsgard, Beth Jorgenson, Ganesh Raveendran, Nadeem Iqbal","doi":"10.1007/s12574-025-00685-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Upper extremity injection of agitated saline using echocardiography is standard for locating patent foramen ovale (PFO), but several studies found the lower extremity to be more sensitive.</p><p><strong>Methods: </strong>In this prospective study, patients were selected who had a prior embolic stroke of undetermined source by history and no PFO identified with transthoracic echocardiography. We placed intravenous access in the upper extremity and used ultrasound-guided access in the superficial greater saphenous vein in the lower extremity, evaluating best view and presence and size of PFO if found.</p><p><strong>Results: </strong>On review of 910 subjects, twenty subjects completed the study. The average greater saphenous vein measured 0.49 ± 0.16 cm in diameter, and depth of 1.07 ± 0.66 cm. The apical four chamber view to visualize the atrial septum was considered superior (p < 0.005) to the subcostal and parasternal short axis views. A PFO was found in five of the twenty subjects with concordance among all readers via lower extremity injection, compared to four subjects via upper extremity injection. Lower extremity injection of contrast identified significantly (p < 0.05) larger PFO compared to upper extremity injection. Complications from greater saphenous vein access included one superficial thrombus, one vasovagal syncope and four with ecchymosis (all < 3cm).</p><p><strong>Conclusions: </strong>PFO are found significantly larger when utilizing the greater saphenous vein of the lower extremity compared to the upper extremity for injection of agitated saline and best visualized with the apical four-chamber view.</p>","PeriodicalId":44837,"journal":{"name":"Journal of Echocardiography","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2025-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Lower vs upper extremity injection of agitated saline for identification of patent foramen ovale (LOCATE).\",\"authors\":\"Carmelo J Panetta, Les B Forgosh, Elizabeth Bisinov, Haitham Hussein, David Benditt, Benjamin Miller, Marat Yanavitski, Marit Thorsgard, Beth Jorgenson, Ganesh Raveendran, Nadeem Iqbal\",\"doi\":\"10.1007/s12574-025-00685-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>Upper extremity injection of agitated saline using echocardiography is standard for locating patent foramen ovale (PFO), but several studies found the lower extremity to be more sensitive.</p><p><strong>Methods: </strong>In this prospective study, patients were selected who had a prior embolic stroke of undetermined source by history and no PFO identified with transthoracic echocardiography. We placed intravenous access in the upper extremity and used ultrasound-guided access in the superficial greater saphenous vein in the lower extremity, evaluating best view and presence and size of PFO if found.</p><p><strong>Results: </strong>On review of 910 subjects, twenty subjects completed the study. The average greater saphenous vein measured 0.49 ± 0.16 cm in diameter, and depth of 1.07 ± 0.66 cm. The apical four chamber view to visualize the atrial septum was considered superior (p < 0.005) to the subcostal and parasternal short axis views. A PFO was found in five of the twenty subjects with concordance among all readers via lower extremity injection, compared to four subjects via upper extremity injection. Lower extremity injection of contrast identified significantly (p < 0.05) larger PFO compared to upper extremity injection. Complications from greater saphenous vein access included one superficial thrombus, one vasovagal syncope and four with ecchymosis (all < 3cm).</p><p><strong>Conclusions: </strong>PFO are found significantly larger when utilizing the greater saphenous vein of the lower extremity compared to the upper extremity for injection of agitated saline and best visualized with the apical four-chamber view.</p>\",\"PeriodicalId\":44837,\"journal\":{\"name\":\"Journal of Echocardiography\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-03-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Echocardiography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12574-025-00685-z\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Echocardiography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12574-025-00685-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的:超声心动图上肢注射搅拌生理盐水是定位卵圆孔未闭(PFO)的标准方法,但一些研究发现下肢更敏感。方法:在这项前瞻性研究中,选择有病史不明来源的栓塞性卒中且经胸超声心动图未发现PFO的患者。我们在上肢放置静脉通路,并在超声引导下进入下肢浅大隐静脉,评估最佳视野,发现PFO的存在和大小。结果:在910名受试者中,20名受试者完成了研究。大隐静脉平均直径0.49±0.16 cm,深度1.07±0.66 cm。结论:与上肢注射搅拌生理盐水相比,使用下肢大隐静脉观察房间隔的PFO明显更大,并且使用根尖四室观察房间隔的效果最好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lower vs upper extremity injection of agitated saline for identification of patent foramen ovale (LOCATE).

Aims: Upper extremity injection of agitated saline using echocardiography is standard for locating patent foramen ovale (PFO), but several studies found the lower extremity to be more sensitive.

Methods: In this prospective study, patients were selected who had a prior embolic stroke of undetermined source by history and no PFO identified with transthoracic echocardiography. We placed intravenous access in the upper extremity and used ultrasound-guided access in the superficial greater saphenous vein in the lower extremity, evaluating best view and presence and size of PFO if found.

Results: On review of 910 subjects, twenty subjects completed the study. The average greater saphenous vein measured 0.49 ± 0.16 cm in diameter, and depth of 1.07 ± 0.66 cm. The apical four chamber view to visualize the atrial septum was considered superior (p < 0.005) to the subcostal and parasternal short axis views. A PFO was found in five of the twenty subjects with concordance among all readers via lower extremity injection, compared to four subjects via upper extremity injection. Lower extremity injection of contrast identified significantly (p < 0.05) larger PFO compared to upper extremity injection. Complications from greater saphenous vein access included one superficial thrombus, one vasovagal syncope and four with ecchymosis (all < 3cm).

Conclusions: PFO are found significantly larger when utilizing the greater saphenous vein of the lower extremity compared to the upper extremity for injection of agitated saline and best visualized with the apical four-chamber view.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Echocardiography
Journal of Echocardiography CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.00
自引率
6.20%
发文量
35
期刊介绍: The Journal of Echocardiography, the official journal of the Japanese Society of Echocardiography, publishes work that contributes to progress in the field and articles in clinical research as well, seeking to develop a new focus and new perspectives for all who are concerned with this discipline. The journal welcomes original investigations, review articles, letters to the editor, editorials, and case image in cardiovascular ultrasound, which will be reviewed by the editorial board. The Journal of Echocardiography provides the best of up-to-date information from around the world, presenting readers with high-impact, original work focusing on pivotal issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信