Martin Rognhaug, Hanne Braathen, Håkon Skogrand Eliassen
{"title":"使用3D打印瓶盖和消毒的500毫升饮用水瓶提取和储存全血-概念验证研究:第2部分。","authors":"Martin Rognhaug, Hanne Braathen, Håkon Skogrand Eliassen","doi":"10.1111/trf.18200","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Disruptions in supply chains during crises and wars necessitate innovative solutions for blood collection. This study evaluates the feasibility and safety of using a 3D-printed bottle cap (BC<sup>2</sup>L) with a standard 500 mL drinking bottle for whole blood collection as an alternative to traditional systems.</p><p><strong>Study design and method: </strong>We conducted a feasibility study with 20 healthy adult volunteers. Participants were randomized to donate blood into either the BC<sup>2</sup>L-drinking bottle setup (Test) or a conventional single blood collection bag (control). Blood samples were analyzed for hemolysis, bacterial contamination, and mechanical integrity immediately post-donation, and at 24 and 72 h. Donation time and donor safety were also assessed. Bacterial growth testing and hematological analyses followed sterile procedures to measure hematological quality.</p><p><strong>Results: </strong>Blood collection was completed within a mean time of 7 min across both groups. Hemolysis levels remained below clinically significant thresholds in both setups, and no bacterial contamination was observed. While the BC<sup>2</sup>L system demonstrated effective blood collection, minor leakage was noted in some bottles during transportation, attributed to the limitations of the 3D-printing process.</p><p><strong>Conclusion: </strong>The BC<sup>2</sup>L system represents a feasible, low-cost alternative for whole blood collection in resource-limited or crisis settings. It demonstrated comparable safety and mechanical integrity to standard systems. However, manufacturing refinements are needed to address leakage during transport. This study supports the potential of the BC<sup>2</sup>L as a valuable tool for enhancing medical preparedness in austere environments.</p>","PeriodicalId":23266,"journal":{"name":"Transfusion","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2025-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Drawing and storing whole blood using a 3D printed bottle cap and a disinfected 500 mL drinking bottle-A proof-of-concept study: Part 2.\",\"authors\":\"Martin Rognhaug, Hanne Braathen, Håkon Skogrand Eliassen\",\"doi\":\"10.1111/trf.18200\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Disruptions in supply chains during crises and wars necessitate innovative solutions for blood collection. This study evaluates the feasibility and safety of using a 3D-printed bottle cap (BC<sup>2</sup>L) with a standard 500 mL drinking bottle for whole blood collection as an alternative to traditional systems.</p><p><strong>Study design and method: </strong>We conducted a feasibility study with 20 healthy adult volunteers. Participants were randomized to donate blood into either the BC<sup>2</sup>L-drinking bottle setup (Test) or a conventional single blood collection bag (control). Blood samples were analyzed for hemolysis, bacterial contamination, and mechanical integrity immediately post-donation, and at 24 and 72 h. Donation time and donor safety were also assessed. Bacterial growth testing and hematological analyses followed sterile procedures to measure hematological quality.</p><p><strong>Results: </strong>Blood collection was completed within a mean time of 7 min across both groups. Hemolysis levels remained below clinically significant thresholds in both setups, and no bacterial contamination was observed. While the BC<sup>2</sup>L system demonstrated effective blood collection, minor leakage was noted in some bottles during transportation, attributed to the limitations of the 3D-printing process.</p><p><strong>Conclusion: </strong>The BC<sup>2</sup>L system represents a feasible, low-cost alternative for whole blood collection in resource-limited or crisis settings. It demonstrated comparable safety and mechanical integrity to standard systems. However, manufacturing refinements are needed to address leakage during transport. This study supports the potential of the BC<sup>2</sup>L as a valuable tool for enhancing medical preparedness in austere environments.</p>\",\"PeriodicalId\":23266,\"journal\":{\"name\":\"Transfusion\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2025-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transfusion\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/trf.18200\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transfusion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/trf.18200","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:危机和战争期间供应链的中断需要创新的采血解决方案。本研究评估了使用3d打印瓶盖(BC2L)和标准500毫升饮用瓶进行全血采集的可行性和安全性,作为传统系统的替代方案。研究设计和方法:我们对20名健康成人志愿者进行了可行性研究。参与者被随机分配将血液捐献到bc2l饮用瓶装置(测试)或传统的单一采血袋(对照组)中。在献血后立即、24小时和72小时对血液样本进行溶血、细菌污染和机械完整性分析。同时对捐赠时间和捐赠者安全性进行了评估。细菌生长测试和血液学分析遵循无菌程序来测量血液学质量。结果:两组患者的平均采血时间均为7 min。在两组试验中,溶血水平均低于临床显著阈值,且未观察到细菌污染。虽然BC2L系统显示了有效的血液采集,但由于3d打印工艺的限制,在运输过程中,一些瓶子出现了轻微的泄漏。结论:在资源有限或危重环境下,BC2L系统是一种可行、低成本的全血采集方法。与标准系统相比,它具有相当的安全性和机械完整性。然而,需要改进制造工艺以解决运输过程中的泄漏问题。这项研究支持BC2L作为在恶劣环境中加强医疗准备的宝贵工具的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Drawing and storing whole blood using a 3D printed bottle cap and a disinfected 500 mL drinking bottle-A proof-of-concept study: Part 2.

Background: Disruptions in supply chains during crises and wars necessitate innovative solutions for blood collection. This study evaluates the feasibility and safety of using a 3D-printed bottle cap (BC2L) with a standard 500 mL drinking bottle for whole blood collection as an alternative to traditional systems.

Study design and method: We conducted a feasibility study with 20 healthy adult volunteers. Participants were randomized to donate blood into either the BC2L-drinking bottle setup (Test) or a conventional single blood collection bag (control). Blood samples were analyzed for hemolysis, bacterial contamination, and mechanical integrity immediately post-donation, and at 24 and 72 h. Donation time and donor safety were also assessed. Bacterial growth testing and hematological analyses followed sterile procedures to measure hematological quality.

Results: Blood collection was completed within a mean time of 7 min across both groups. Hemolysis levels remained below clinically significant thresholds in both setups, and no bacterial contamination was observed. While the BC2L system demonstrated effective blood collection, minor leakage was noted in some bottles during transportation, attributed to the limitations of the 3D-printing process.

Conclusion: The BC2L system represents a feasible, low-cost alternative for whole blood collection in resource-limited or crisis settings. It demonstrated comparable safety and mechanical integrity to standard systems. However, manufacturing refinements are needed to address leakage during transport. This study supports the potential of the BC2L as a valuable tool for enhancing medical preparedness in austere environments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Transfusion
Transfusion 医学-血液学
CiteScore
4.70
自引率
20.70%
发文量
426
审稿时长
1 months
期刊介绍: TRANSFUSION is the foremost publication in the world for new information regarding transfusion medicine. Written by and for members of AABB and other health-care workers, TRANSFUSION reports on the latest technical advances, discusses opposing viewpoints regarding controversial issues, and presents key conference proceedings. In addition to blood banking and transfusion medicine topics, TRANSFUSION presents submissions concerning patient blood management, tissue transplantation and hematopoietic, cellular, and gene therapies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信