{"title":"iStent®注射系统治疗东亚开角型青光眼的2年纵向评价","authors":"Ru Jian Jonathan Teoh, Rupini Yogesvaran, Felicia Foo Yuen Cheng, Roslinah Muji","doi":"10.4103/ojo.ojo_223_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aim of the study was to assess the midterm efficacy and safety of the iStent glaucoma device in patients with open-angle glaucoma (OAG).</p><p><strong>Materials and methods: </strong>We conducted a retrospective case series of all patients implanted with iStent inject® in OAG. Primary outcomes included intraocular pressure (IOP) and the reduction of antiglaucoma medications. Safety outcomes comprised adverse complications, additional surgeries, and postoperative best-corrected visual acuity (BCVA).</p><p><strong>Results: </strong>Eight eyes from eight patients were included in this series. The mean age was 56.3 ± 17.5 years. Six eyes had primary OAG and two eyes had secondary OAG. The majority of eyes (75%) had mild-to-moderate glaucoma. Five eyes underwent combined surgery, whereas the remaining three eyes underwent a standalone procedure. The mean baseline IOP was 22.9 ± 8.2 mmHg, and the mean IOP at 2 years after the procedure was 13.6 ± 2.8 mmHg. There was a 44.5% (10.2 ± 2.5 mmHg; <i>P</i> = 0.002) IOP reduction over 2 years. There was also a reduction in medication burden from a baseline mean of 3.4 ± 0.7 to 2.0 ± 1.2 (<i>P</i> = 0.17). There was no documented intraoperative adverse complication, whereas one patient required trabeculectomy post iStent for IOP control.</p><p><strong>Conclusion: </strong>iStent inject implantation safely reduced IOP and medication burden up to 24 months postoperative.</p>","PeriodicalId":19461,"journal":{"name":"Oman Journal of Ophthalmology","volume":"18 1","pages":"28-32"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11925374/pdf/","citationCount":"0","resultStr":"{\"title\":\"A 2-year longitudinal evaluation of the iStent inject<sup>®</sup> system for open-angle glaucoma in East Asian eyes.\",\"authors\":\"Ru Jian Jonathan Teoh, Rupini Yogesvaran, Felicia Foo Yuen Cheng, Roslinah Muji\",\"doi\":\"10.4103/ojo.ojo_223_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The aim of the study was to assess the midterm efficacy and safety of the iStent glaucoma device in patients with open-angle glaucoma (OAG).</p><p><strong>Materials and methods: </strong>We conducted a retrospective case series of all patients implanted with iStent inject® in OAG. Primary outcomes included intraocular pressure (IOP) and the reduction of antiglaucoma medications. Safety outcomes comprised adverse complications, additional surgeries, and postoperative best-corrected visual acuity (BCVA).</p><p><strong>Results: </strong>Eight eyes from eight patients were included in this series. The mean age was 56.3 ± 17.5 years. Six eyes had primary OAG and two eyes had secondary OAG. The majority of eyes (75%) had mild-to-moderate glaucoma. Five eyes underwent combined surgery, whereas the remaining three eyes underwent a standalone procedure. The mean baseline IOP was 22.9 ± 8.2 mmHg, and the mean IOP at 2 years after the procedure was 13.6 ± 2.8 mmHg. There was a 44.5% (10.2 ± 2.5 mmHg; <i>P</i> = 0.002) IOP reduction over 2 years. There was also a reduction in medication burden from a baseline mean of 3.4 ± 0.7 to 2.0 ± 1.2 (<i>P</i> = 0.17). There was no documented intraoperative adverse complication, whereas one patient required trabeculectomy post iStent for IOP control.</p><p><strong>Conclusion: </strong>iStent inject implantation safely reduced IOP and medication burden up to 24 months postoperative.</p>\",\"PeriodicalId\":19461,\"journal\":{\"name\":\"Oman Journal of Ophthalmology\",\"volume\":\"18 1\",\"pages\":\"28-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11925374/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oman Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ojo.ojo_223_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oman Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ojo.ojo_223_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
A 2-year longitudinal evaluation of the iStent inject® system for open-angle glaucoma in East Asian eyes.
Background: The aim of the study was to assess the midterm efficacy and safety of the iStent glaucoma device in patients with open-angle glaucoma (OAG).
Materials and methods: We conducted a retrospective case series of all patients implanted with iStent inject® in OAG. Primary outcomes included intraocular pressure (IOP) and the reduction of antiglaucoma medications. Safety outcomes comprised adverse complications, additional surgeries, and postoperative best-corrected visual acuity (BCVA).
Results: Eight eyes from eight patients were included in this series. The mean age was 56.3 ± 17.5 years. Six eyes had primary OAG and two eyes had secondary OAG. The majority of eyes (75%) had mild-to-moderate glaucoma. Five eyes underwent combined surgery, whereas the remaining three eyes underwent a standalone procedure. The mean baseline IOP was 22.9 ± 8.2 mmHg, and the mean IOP at 2 years after the procedure was 13.6 ± 2.8 mmHg. There was a 44.5% (10.2 ± 2.5 mmHg; P = 0.002) IOP reduction over 2 years. There was also a reduction in medication burden from a baseline mean of 3.4 ± 0.7 to 2.0 ± 1.2 (P = 0.17). There was no documented intraoperative adverse complication, whereas one patient required trabeculectomy post iStent for IOP control.
Conclusion: iStent inject implantation safely reduced IOP and medication burden up to 24 months postoperative.
期刊介绍:
To provide a platform for scientific expression of the Oman Ophthalmic Society and the international Ophthalmic community and to provide opportunities for free exchange of ideas and information. To serve as a valuable resource for ophthalmologists, eye-care providers including optometrists, orthoptists, other health care professionals and research workers in all aspects of the field of visual science.