使用偶极环阵列线圈对7 t31p - mrsi进行区域分解心脏代谢。

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Jabrane Karkouri, Will Watson, Ria Forner, Jonathan R Weir-McCall, Tracy Horn, Marion Hill, Stephen Hoole, Dennis Klomp, Christopher T Rodgers
{"title":"使用偶极环阵列线圈对7 t31p - mrsi进行区域分解心脏代谢。","authors":"Jabrane Karkouri, Will Watson, Ria Forner, Jonathan R Weir-McCall, Tracy Horn, Marion Hill, Stephen Hoole, Dennis Klomp, Christopher T Rodgers","doi":"10.1002/mrm.30492","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We introduce a novel commercial phosphorus-31 (<sup>31</sup>P) dipole-loop array coil, describing the coil hardware and testing its performance on phantoms. We used this coil to assess cardiac metabolism per region in healthy volunteers.</p><p><strong>Methods: </strong>B<sub>1</sub> <sup>+</sup> field maps were simulated and compared to maps measured with a set of CSI sequences with varying voltages. Seventeen volunteers were scanned with 7 T phosphorus-31 magnetic resonance spectroscopic imaging (<sup>31</sup>P-MRSI). Reproducibility was assessed in nine of these volunteers. Strain was measured for six of these volunteers at 3 T.</p><p><strong>Results: </strong>Blood- and saturation-corrected Phosphocreatine/γ-adenosine triphosphate (PCr/ATP) ratios were measured for four regions of the left ventricle: 1.86 in septum, 2.25 in anterior wall, 1.41 in inferior wall, and 1.53 in lateral wall, respectively. These are in the expected range compared to previous studies. B<sub>1</sub> <sup>+</sup> maps show good signal uniformity around the position of the heart (0.13 ± 0.06 μT/sqrt(W)). Intrasession and intersession coefficients of reproducibility were 0.22-0.88 and 0.29-0.79, respectively. Linear modeling shows that regional PCr/γATP correlates with circumferential strain but not radial strain. This requires corroboration by a larger study including patients with impaired function and energetics.</p><p><strong>Conclusion: </strong>Dipole-loop array coils present a promising new approach for human cardiac <sup>31</sup>P-MRSI at 7 T. Their favorable B<sub>1</sub> <sup>+</sup> uniformity at depth and specific absorption rate over loop arrays and improved SNR when combined with loops for reception could be beneficial for further clinical studies measuring energetics by <sup>31</sup>P-MRSI at 7 T. The new capability to assess PCr/γATP ratios across the whole left ventricle could enable clinical studies to investigate regional changes in cardiac energetics for the first time.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Regionally resolved cardiac metabolism using a dipole-loop array coil for 7 T <sup>31</sup>P-MRSI.\",\"authors\":\"Jabrane Karkouri, Will Watson, Ria Forner, Jonathan R Weir-McCall, Tracy Horn, Marion Hill, Stephen Hoole, Dennis Klomp, Christopher T Rodgers\",\"doi\":\"10.1002/mrm.30492\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We introduce a novel commercial phosphorus-31 (<sup>31</sup>P) dipole-loop array coil, describing the coil hardware and testing its performance on phantoms. We used this coil to assess cardiac metabolism per region in healthy volunteers.</p><p><strong>Methods: </strong>B<sub>1</sub> <sup>+</sup> field maps were simulated and compared to maps measured with a set of CSI sequences with varying voltages. Seventeen volunteers were scanned with 7 T phosphorus-31 magnetic resonance spectroscopic imaging (<sup>31</sup>P-MRSI). Reproducibility was assessed in nine of these volunteers. Strain was measured for six of these volunteers at 3 T.</p><p><strong>Results: </strong>Blood- and saturation-corrected Phosphocreatine/γ-adenosine triphosphate (PCr/ATP) ratios were measured for four regions of the left ventricle: 1.86 in septum, 2.25 in anterior wall, 1.41 in inferior wall, and 1.53 in lateral wall, respectively. These are in the expected range compared to previous studies. B<sub>1</sub> <sup>+</sup> maps show good signal uniformity around the position of the heart (0.13 ± 0.06 μT/sqrt(W)). Intrasession and intersession coefficients of reproducibility were 0.22-0.88 and 0.29-0.79, respectively. Linear modeling shows that regional PCr/γATP correlates with circumferential strain but not radial strain. This requires corroboration by a larger study including patients with impaired function and energetics.</p><p><strong>Conclusion: </strong>Dipole-loop array coils present a promising new approach for human cardiac <sup>31</sup>P-MRSI at 7 T. Their favorable B<sub>1</sub> <sup>+</sup> uniformity at depth and specific absorption rate over loop arrays and improved SNR when combined with loops for reception could be beneficial for further clinical studies measuring energetics by <sup>31</sup>P-MRSI at 7 T. The new capability to assess PCr/γATP ratios across the whole left ventricle could enable clinical studies to investigate regional changes in cardiac energetics for the first time.</p>\",\"PeriodicalId\":18065,\"journal\":{\"name\":\"Magnetic Resonance in Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/mrm.30492\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30492","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:介绍了一种新型的商用磷-31 (31P)偶极环阵列线圈,描述了线圈的硬件结构并测试了其在幻影上的性能。我们使用这个线圈来评估健康志愿者各区域的心脏代谢。方法:模拟B1 +场图,并与一组不同电压的CSI序列测得的图进行比较。17名志愿者接受7t磷-31磁共振波谱成像(31P-MRSI)扫描。对其中9名志愿者的再现性进行了评估。其中6名志愿者在3t时进行了应变测量。结果:经血液校正和饱和校正后,测定了左心室四个区域的磷酸肌酸/γ-三磷酸腺苷(PCr/ATP)比值:间隔区1.86,前壁2.25,下壁1.41,侧壁1.53。与之前的研究相比,这些都在预期范围内。B1 +图显示心脏周围信号均匀性好(0.13±0.06 μT/sqrt(W))。再现性内、间系数分别为0.22 ~ 0.88和0.29 ~ 0.79。线性模型表明,区域PCr/γ - atp与周向应变相关,而与径向应变无关。这需要一项更大的研究来证实,研究对象包括功能和能量受损的患者。结论:偶极环阵列线圈是一种很有前途的7 T人体心脏31P-MRSI新方法。它们在深度处良好的B1 +均匀性和环路阵列的特定吸收率,以及与接收环路相结合时提高的信噪比,可能有利于进一步的临床研究,即在7 T时通过31P-MRSI测量能量。评估整个左心室PCr/γ - atp比率的新能力可以使临床研究首次研究心脏能量学的区域变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Regionally resolved cardiac metabolism using a dipole-loop array coil for 7 T 31P-MRSI.

Purpose: We introduce a novel commercial phosphorus-31 (31P) dipole-loop array coil, describing the coil hardware and testing its performance on phantoms. We used this coil to assess cardiac metabolism per region in healthy volunteers.

Methods: B1 + field maps were simulated and compared to maps measured with a set of CSI sequences with varying voltages. Seventeen volunteers were scanned with 7 T phosphorus-31 magnetic resonance spectroscopic imaging (31P-MRSI). Reproducibility was assessed in nine of these volunteers. Strain was measured for six of these volunteers at 3 T.

Results: Blood- and saturation-corrected Phosphocreatine/γ-adenosine triphosphate (PCr/ATP) ratios were measured for four regions of the left ventricle: 1.86 in septum, 2.25 in anterior wall, 1.41 in inferior wall, and 1.53 in lateral wall, respectively. These are in the expected range compared to previous studies. B1 + maps show good signal uniformity around the position of the heart (0.13 ± 0.06 μT/sqrt(W)). Intrasession and intersession coefficients of reproducibility were 0.22-0.88 and 0.29-0.79, respectively. Linear modeling shows that regional PCr/γATP correlates with circumferential strain but not radial strain. This requires corroboration by a larger study including patients with impaired function and energetics.

Conclusion: Dipole-loop array coils present a promising new approach for human cardiac 31P-MRSI at 7 T. Their favorable B1 + uniformity at depth and specific absorption rate over loop arrays and improved SNR when combined with loops for reception could be beneficial for further clinical studies measuring energetics by 31P-MRSI at 7 T. The new capability to assess PCr/γATP ratios across the whole left ventricle could enable clinical studies to investigate regional changes in cardiac energetics for the first time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信