{"title":"泪膜稳定性对角膜屈光度测量及白内障手术计划的影响","authors":"Yuanfeng Jiang ,&nbsp;Xiteng Chen ,&nbsp;Yichen Gao,&nbsp;Nan Gao,&nbsp;Huiyu Wang,&nbsp;Yanwen Feng,&nbsp;Meisa Li,&nbsp;Luning Qin,&nbsp;Fei Li,&nbsp;Shaozhen Zhao,&nbsp;Shaochong Bu,&nbsp;Fang Tian","doi":"10.1016/j.aopr.2025.02.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>This prospective cohort study aimed to assess the influence of tear film stability on corneal refractive power measurement and surgical planning in cataract patients.</div></div><div><h3>Methods</h3><div>Participants were divided into tear film instability (tear film stability level 2) and control (level 0–1) groups based on Keratograph 5M results. Using IOL Master 700, two consecutive measurements were obtained with a 10-min interval. Parameters including standard keratometry (Kf, Ks and K), keratometric corneal astigmatism (KCA), total keratometry (TKf, TKs and TK) and total corneal astigmatism (TCA) were recorded. IOL power was calculated using SRK-T, SRK-T TK, Haigis, Haigis TK, Barrett Universal II, and Barrett Universal II TK formulas.</div></div><div><h3>Results</h3><div>The results showed significantly higher differences between two measurements in Kf, K, KCA, TKf, TK, and TCA, as well as the vector variability of corneal astigmatism in the tear film instability group (all <em>P</em> ​&lt; ​0.05). Of all formulas, only the SRK-T formula displayed significantly higher variability in IOL power calculations in the tear film instability group compared to the control group (<em>P</em> ​&lt; ​0.05).</div></div><div><h3>Conclusions</h3><div>This study highlights that tear film instability can lead to deviations in corneal refractive power and astigmatism measurements, contributing to increased prediction errors in IOL power calculation, particularly with the SRK-T formula.</div></div>","PeriodicalId":72103,"journal":{"name":"Advances in ophthalmology practice and research","volume":"5 2","pages":"Pages 100-106"},"PeriodicalIF":3.4000,"publicationDate":"2025-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of tear film stability on corneal refractive power measurement and surgical planning for cataract\",\"authors\":\"Yuanfeng Jiang ,&nbsp;Xiteng Chen ,&nbsp;Yichen Gao,&nbsp;Nan Gao,&nbsp;Huiyu Wang,&nbsp;Yanwen Feng,&nbsp;Meisa Li,&nbsp;Luning Qin,&nbsp;Fei Li,&nbsp;Shaozhen Zhao,&nbsp;Shaochong Bu,&nbsp;Fang Tian\",\"doi\":\"10.1016/j.aopr.2025.02.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><div>This prospective cohort study aimed to assess the influence of tear film stability on corneal refractive power measurement and surgical planning in cataract patients.</div></div><div><h3>Methods</h3><div>Participants were divided into tear film instability (tear film stability level 2) and control (level 0–1) groups based on Keratograph 5M results. Using IOL Master 700, two consecutive measurements were obtained with a 10-min interval. Parameters including standard keratometry (Kf, Ks and K), keratometric corneal astigmatism (KCA), total keratometry (TKf, TKs and TK) and total corneal astigmatism (TCA) were recorded. IOL power was calculated using SRK-T, SRK-T TK, Haigis, Haigis TK, Barrett Universal II, and Barrett Universal II TK formulas.</div></div><div><h3>Results</h3><div>The results showed significantly higher differences between two measurements in Kf, K, KCA, TKf, TK, and TCA, as well as the vector variability of corneal astigmatism in the tear film instability group (all <em>P</em> ​&lt; ​0.05). Of all formulas, only the SRK-T formula displayed significantly higher variability in IOL power calculations in the tear film instability group compared to the control group (<em>P</em> ​&lt; ​0.05).</div></div><div><h3>Conclusions</h3><div>This study highlights that tear film instability can lead to deviations in corneal refractive power and astigmatism measurements, contributing to increased prediction errors in IOL power calculation, particularly with the SRK-T formula.</div></div>\",\"PeriodicalId\":72103,\"journal\":{\"name\":\"Advances in ophthalmology practice and research\",\"volume\":\"5 2\",\"pages\":\"Pages 100-106\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2025-02-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in ophthalmology practice and research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667376225000046\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in ophthalmology practice and research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667376225000046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的本前瞻性队列研究旨在评估泪膜稳定性对白内障患者角膜屈光度测量和手术计划的影响。方法根据角膜镜5M结果将患者分为泪膜不稳定(泪膜稳定性2级)组和对照组(0-1级)。使用IOL Master 700,连续两次测量,间隔10分钟。记录标准角膜屈光度(Kf、Ks和K)、角膜屈光度(KCA)、总角膜屈光度(TKf、TKs和TK)和角膜总散光(TCA)等参数。采用SRK-T、SRK-T TK、Haigis、Haigis TK、Barrett Universal II和Barrett Universal II TK公式计算人工晶状体度数。结果泪膜不稳定组的Kf、K、KCA、TKf、TK、TCA以及角膜散光的矢量变异性在两次测量中差异有显著性意义(P <;0.05)。在所有公式中,只有SRK-T公式在泪膜不稳定组的人工晶状体度数计算中显示出明显高于对照组的变异性(P <;0.05)。本研究强调泪膜不稳定会导致角膜屈光度数和散光测量的偏差,导致人工晶状体度数计算的预测误差增加,尤其是SRK-T公式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of tear film stability on corneal refractive power measurement and surgical planning for cataract

Purpose

This prospective cohort study aimed to assess the influence of tear film stability on corneal refractive power measurement and surgical planning in cataract patients.

Methods

Participants were divided into tear film instability (tear film stability level 2) and control (level 0–1) groups based on Keratograph 5M results. Using IOL Master 700, two consecutive measurements were obtained with a 10-min interval. Parameters including standard keratometry (Kf, Ks and K), keratometric corneal astigmatism (KCA), total keratometry (TKf, TKs and TK) and total corneal astigmatism (TCA) were recorded. IOL power was calculated using SRK-T, SRK-T TK, Haigis, Haigis TK, Barrett Universal II, and Barrett Universal II TK formulas.

Results

The results showed significantly higher differences between two measurements in Kf, K, KCA, TKf, TK, and TCA, as well as the vector variability of corneal astigmatism in the tear film instability group (all P ​< ​0.05). Of all formulas, only the SRK-T formula displayed significantly higher variability in IOL power calculations in the tear film instability group compared to the control group (P ​< ​0.05).

Conclusions

This study highlights that tear film instability can lead to deviations in corneal refractive power and astigmatism measurements, contributing to increased prediction errors in IOL power calculation, particularly with the SRK-T formula.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
0
审稿时长
66 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信