新生儿静脉留置管中应力性溶血的比较:切应力、暴露时间和溶血指标的理论与实验分析。

Q2 Medicine
Journal of neonatal-perinatal medicine Pub Date : 2025-05-01 Epub Date: 2025-03-21 DOI:10.1177/19345798251326071
Gordon Y Chang, Cynthia A Cox, Ellen A Kane, Giovanna Palermo Tye, Paul Fawcett, Thomas H Shaffer
{"title":"新生儿静脉留置管中应力性溶血的比较:切应力、暴露时间和溶血指标的理论与实验分析。","authors":"Gordon Y Chang, Cynthia A Cox, Ellen A Kane, Giovanna Palermo Tye, Paul Fawcett, Thomas H Shaffer","doi":"10.1177/19345798251326071","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundSeveral studies report hemolysis when packed red blood cells (PRBCs) are transfused through small-inner-diameter (ID) catheters using presence of biomarkers but do not address cause and amount of hemolysis. This study aims to determine the cause and index of hemolysis percent (IH%) when PRBCs are infused through small-ID catheters.MethodsThe IH% was calculated using Giersiepen's empirical power law, which describes a relationship between hemolysis and magnitude of shear stress and exposure time. Six- and 27-day-old PRBCs were infused through five catheters with IDs of 0.20 mm to 0.70 mm at infusion rates of 3 mL and 10 mL/hour. Shear stress and exposure time were calculated. Data were analyzed as a function of catheter ID, infusion rates, and blood age.ResultsThe study demonstrated that shear stress was supraphysiologic during laminar flow in catheters with IDs of 0.20 mm and 0.28 mm. These catheters' IH% were ∼117 times higher at 3 mL/hour and ∼75 times higher at 10 mL/hour than catheters with larger IDs of 0.48 mm, 0.51 mm, and 0.70 mm. For blood age, in catheters with IDs of 0.20 mm and 0.28 mm, IH% was ∼155 times higher at 6 days and ∼76 times higher at 27 days than in catheters with IDs of 0.48 mm, 0.51 mm, and 0.70 mm.ConclusionsThis study demonstrated that when RBCs are subjected to supraphysiologic shear stress in catheters with IDs of ≤0.28 mm, index of hemolysis is greater than in catheters with IDs ≥0.48 mm.</p>","PeriodicalId":16537,"journal":{"name":"Journal of neonatal-perinatal medicine","volume":" ","pages":"255-269"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of stress-induced hemolysis in neonatal intravenous catheters: Theoretical and experimental analysis of shear stress, exposure time, and index of hemolysis.\",\"authors\":\"Gordon Y Chang, Cynthia A Cox, Ellen A Kane, Giovanna Palermo Tye, Paul Fawcett, Thomas H Shaffer\",\"doi\":\"10.1177/19345798251326071\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>BackgroundSeveral studies report hemolysis when packed red blood cells (PRBCs) are transfused through small-inner-diameter (ID) catheters using presence of biomarkers but do not address cause and amount of hemolysis. This study aims to determine the cause and index of hemolysis percent (IH%) when PRBCs are infused through small-ID catheters.MethodsThe IH% was calculated using Giersiepen's empirical power law, which describes a relationship between hemolysis and magnitude of shear stress and exposure time. Six- and 27-day-old PRBCs were infused through five catheters with IDs of 0.20 mm to 0.70 mm at infusion rates of 3 mL and 10 mL/hour. Shear stress and exposure time were calculated. Data were analyzed as a function of catheter ID, infusion rates, and blood age.ResultsThe study demonstrated that shear stress was supraphysiologic during laminar flow in catheters with IDs of 0.20 mm and 0.28 mm. These catheters' IH% were ∼117 times higher at 3 mL/hour and ∼75 times higher at 10 mL/hour than catheters with larger IDs of 0.48 mm, 0.51 mm, and 0.70 mm. For blood age, in catheters with IDs of 0.20 mm and 0.28 mm, IH% was ∼155 times higher at 6 days and ∼76 times higher at 27 days than in catheters with IDs of 0.48 mm, 0.51 mm, and 0.70 mm.ConclusionsThis study demonstrated that when RBCs are subjected to supraphysiologic shear stress in catheters with IDs of ≤0.28 mm, index of hemolysis is greater than in catheters with IDs ≥0.48 mm.</p>\",\"PeriodicalId\":16537,\"journal\":{\"name\":\"Journal of neonatal-perinatal medicine\",\"volume\":\" \",\"pages\":\"255-269\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neonatal-perinatal medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/19345798251326071\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neonatal-perinatal medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19345798251326071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:一些研究报道,当使用生物标志物通过小内径(ID)导管输入填充红细胞(prbc)时,存在溶血现象,但没有解决溶血的原因和数量。本研究旨在确定红细胞通过小径导管输注时溶血率(IH%)的原因和指标。方法采用Giersiepen经验幂定律计算溶血率,该定律描述了溶血率与剪切应力大小和暴露时间的关系。6日龄和27日龄的红细胞通过5根id为0.20 mm至0.70 mm的导管,以3 mL和10 mL/小时的输注速率输注。计算剪切应力和暴露时间。将数据作为导管ID、输注速率和血龄的函数进行分析。结果在直径为0.20 mm和0.28 mm的导管中,剪切应力在层流过程中是超生理的。这些导管的IH%在3 mL/小时时比直径较大的导管(0.48 mm、0.51 mm和0.70 mm)高117倍,在10 mL/小时时高75倍。在血龄方面,直径为0.20 mm和0.28 mm的导管6天IH%比直径为0.48 mm、0.51 mm和0.70 mm的导管高~ 155倍,27天IH%比直径为0.48 mm的导管高~ 76倍。结论本研究表明,当红细胞在直径≤0.28 mm的导管中受到超生理剪切应力时,溶血指数大于直径≥0.48 mm的导管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of stress-induced hemolysis in neonatal intravenous catheters: Theoretical and experimental analysis of shear stress, exposure time, and index of hemolysis.

BackgroundSeveral studies report hemolysis when packed red blood cells (PRBCs) are transfused through small-inner-diameter (ID) catheters using presence of biomarkers but do not address cause and amount of hemolysis. This study aims to determine the cause and index of hemolysis percent (IH%) when PRBCs are infused through small-ID catheters.MethodsThe IH% was calculated using Giersiepen's empirical power law, which describes a relationship between hemolysis and magnitude of shear stress and exposure time. Six- and 27-day-old PRBCs were infused through five catheters with IDs of 0.20 mm to 0.70 mm at infusion rates of 3 mL and 10 mL/hour. Shear stress and exposure time were calculated. Data were analyzed as a function of catheter ID, infusion rates, and blood age.ResultsThe study demonstrated that shear stress was supraphysiologic during laminar flow in catheters with IDs of 0.20 mm and 0.28 mm. These catheters' IH% were ∼117 times higher at 3 mL/hour and ∼75 times higher at 10 mL/hour than catheters with larger IDs of 0.48 mm, 0.51 mm, and 0.70 mm. For blood age, in catheters with IDs of 0.20 mm and 0.28 mm, IH% was ∼155 times higher at 6 days and ∼76 times higher at 27 days than in catheters with IDs of 0.48 mm, 0.51 mm, and 0.70 mm.ConclusionsThis study demonstrated that when RBCs are subjected to supraphysiologic shear stress in catheters with IDs of ≤0.28 mm, index of hemolysis is greater than in catheters with IDs ≥0.48 mm.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of neonatal-perinatal medicine
Journal of neonatal-perinatal medicine Medicine-Pediatrics, Perinatology and Child Health
CiteScore
2.00
自引率
0.00%
发文量
124
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信