{"title":"前段光学相干层析成像在Wilson病Kayser-Fleischer环检测中的应用。","authors":"Bingjie Shi, Yi Chen","doi":"10.1097/ICO.0000000000003843","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the presentation of Kayser-Fleischer (KF) rings in the cornea using anterior segment optical coherence tomography (AS-OCT) in patients with Wilson disease (WD).</p><p><strong>Methods: </strong>A retrospective analysis was conducted on the clinical data from 31 patients (62 eyes) who were diagnosed with WD, were positive for KF rings, and who were admitted to our hospital between August 2020 and December 2022. All patients underwent slit-lamp and AS-OCT examinations, with the KF ring width measured on AS-OCT grayscale images.</p><p><strong>Results: </strong>On AS-OCT, the KF ring appeared as a high-reflective band at the level of Descemet membrane. The color band on AS-OCT displayed the ring in shades of yellow-green, yellow, or orange. The width of the KF ring was measured accurately using AS-OCT.</p><p><strong>Conclusions: </strong>AS-OCT, when combined with slit-lamp examination, provides a reliable method for evaluating KF rings in patients with WD. The grayscale measurements obtained via AS-OCT offer precise quantification of the corneal KF ring width.</p>","PeriodicalId":10710,"journal":{"name":"Cornea","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of Anterior Segment Optical Coherence Tomography in Detecting Kayser-Fleischer Rings in Wilson Disease.\",\"authors\":\"Bingjie Shi, Yi Chen\",\"doi\":\"10.1097/ICO.0000000000003843\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the presentation of Kayser-Fleischer (KF) rings in the cornea using anterior segment optical coherence tomography (AS-OCT) in patients with Wilson disease (WD).</p><p><strong>Methods: </strong>A retrospective analysis was conducted on the clinical data from 31 patients (62 eyes) who were diagnosed with WD, were positive for KF rings, and who were admitted to our hospital between August 2020 and December 2022. All patients underwent slit-lamp and AS-OCT examinations, with the KF ring width measured on AS-OCT grayscale images.</p><p><strong>Results: </strong>On AS-OCT, the KF ring appeared as a high-reflective band at the level of Descemet membrane. The color band on AS-OCT displayed the ring in shades of yellow-green, yellow, or orange. The width of the KF ring was measured accurately using AS-OCT.</p><p><strong>Conclusions: </strong>AS-OCT, when combined with slit-lamp examination, provides a reliable method for evaluating KF rings in patients with WD. The grayscale measurements obtained via AS-OCT offer precise quantification of the corneal KF ring width.</p>\",\"PeriodicalId\":10710,\"journal\":{\"name\":\"Cornea\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cornea\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICO.0000000000003843\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cornea","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICO.0000000000003843","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Application of Anterior Segment Optical Coherence Tomography in Detecting Kayser-Fleischer Rings in Wilson Disease.
Purpose: To evaluate the presentation of Kayser-Fleischer (KF) rings in the cornea using anterior segment optical coherence tomography (AS-OCT) in patients with Wilson disease (WD).
Methods: A retrospective analysis was conducted on the clinical data from 31 patients (62 eyes) who were diagnosed with WD, were positive for KF rings, and who were admitted to our hospital between August 2020 and December 2022. All patients underwent slit-lamp and AS-OCT examinations, with the KF ring width measured on AS-OCT grayscale images.
Results: On AS-OCT, the KF ring appeared as a high-reflective band at the level of Descemet membrane. The color band on AS-OCT displayed the ring in shades of yellow-green, yellow, or orange. The width of the KF ring was measured accurately using AS-OCT.
Conclusions: AS-OCT, when combined with slit-lamp examination, provides a reliable method for evaluating KF rings in patients with WD. The grayscale measurements obtained via AS-OCT offer precise quantification of the corneal KF ring width.
期刊介绍:
For corneal specialists and for all general ophthalmologists with an interest in this exciting subspecialty, Cornea brings together the latest clinical and basic research on the cornea and the anterior segment of the eye. Each volume is peer-reviewed by Cornea''s board of world-renowned experts and fully indexed in archival format. Your subscription brings you the latest developments in your field and a growing library of valuable professional references.
Sponsored by The Cornea Society which was founded as the Castroviejo Cornea Society in 1975.