披着羊皮的狼:多发性骨髓瘤患者的假性低碳酸盐血症。

IF 1 Q3 MEDICINE, GENERAL & INTERNAL
Cureus Pub Date : 2025-03-18 eCollection Date: 2025-03-01 DOI:10.7759/cureus.80782
Ziad Alahmadi, Zain Haq, Ami Patel, Joshua D King
{"title":"披着羊皮的狼:多发性骨髓瘤患者的假性低碳酸盐血症。","authors":"Ziad Alahmadi, Zain Haq, Ami Patel, Joshua D King","doi":"10.7759/cureus.80782","DOIUrl":null,"url":null,"abstract":"<p><p>There are multiple methods to measure serum bicarbonate level which is crucial for diagnosis and management of acid-base disturbances. The most common method is directly measuring the total serum carbon dioxide (CO<sub>2</sub>) concentration in a basic metabolic panel. Another method is by indirect calculation of the bicarbonate concentration via the Henderson-Hasselbalch equation using the measured pH and partial pressure of CO<sub>2</sub> (pCO<sub>2</sub>) in plasma. Multiple confounders can cause discrepancies in the measured bicarbonate in each method, such as increased concentration of serum lipids or proteins, that can alter measurement assays, leading to spuriously low serum bicarbonate values. In our case, we present a patient with falsely low reported bicarbonate levels in the setting of increased paraproteins due to multiple myeloma.</p>","PeriodicalId":93960,"journal":{"name":"Cureus","volume":"17 3","pages":"e80782"},"PeriodicalIF":1.0000,"publicationDate":"2025-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11919310/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Wolf in Sheep's Clothing: Pseudohypobicarbonatemia in a Patient With Multiple Myeloma.\",\"authors\":\"Ziad Alahmadi, Zain Haq, Ami Patel, Joshua D King\",\"doi\":\"10.7759/cureus.80782\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>There are multiple methods to measure serum bicarbonate level which is crucial for diagnosis and management of acid-base disturbances. The most common method is directly measuring the total serum carbon dioxide (CO<sub>2</sub>) concentration in a basic metabolic panel. Another method is by indirect calculation of the bicarbonate concentration via the Henderson-Hasselbalch equation using the measured pH and partial pressure of CO<sub>2</sub> (pCO<sub>2</sub>) in plasma. Multiple confounders can cause discrepancies in the measured bicarbonate in each method, such as increased concentration of serum lipids or proteins, that can alter measurement assays, leading to spuriously low serum bicarbonate values. In our case, we present a patient with falsely low reported bicarbonate levels in the setting of increased paraproteins due to multiple myeloma.</p>\",\"PeriodicalId\":93960,\"journal\":{\"name\":\"Cureus\",\"volume\":\"17 3\",\"pages\":\"e80782\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2025-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11919310/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cureus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7759/cureus.80782\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cureus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7759/cureus.80782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

测定血清碳酸氢盐水平的方法多种多样,对酸碱紊乱的诊断和治疗至关重要。最常用的方法是在基础代谢组中直接测量血清总二氧化碳(CO2)浓度。另一种方法是通过测量等离子体中pH值和CO2分压(pCO2),通过Henderson-Hasselbalch方程间接计算碳酸氢盐浓度。多种混杂因素可能导致每种方法中测量的碳酸氢盐的差异,例如血清脂质或蛋白质浓度的增加,这可能改变测量分析,导致虚假的低血清碳酸氢盐值。在我们的病例中,我们报告了一个患者,在多发性骨髓瘤引起的副蛋白增加的情况下,报告了错误的低碳酸氢盐水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Wolf in Sheep's Clothing: Pseudohypobicarbonatemia in a Patient With Multiple Myeloma.

There are multiple methods to measure serum bicarbonate level which is crucial for diagnosis and management of acid-base disturbances. The most common method is directly measuring the total serum carbon dioxide (CO2) concentration in a basic metabolic panel. Another method is by indirect calculation of the bicarbonate concentration via the Henderson-Hasselbalch equation using the measured pH and partial pressure of CO2 (pCO2) in plasma. Multiple confounders can cause discrepancies in the measured bicarbonate in each method, such as increased concentration of serum lipids or proteins, that can alter measurement assays, leading to spuriously low serum bicarbonate values. In our case, we present a patient with falsely low reported bicarbonate levels in the setting of increased paraproteins due to multiple myeloma.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信