Wenjing Sheng, Qifeng Zhu, Hanyi Dai, Dao Zhou, Xianbao Liu
{"title":"动脉血压升高对经导管主动脉瓣置换术后生物人工瓣膜钙化和失效的影响。","authors":"Wenjing Sheng, Qifeng Zhu, Hanyi Dai, Dao Zhou, Xianbao Liu","doi":"10.3724/zdxbyxb-2024-0391","DOIUrl":null,"url":null,"abstract":"<p><p>Transcatheter aortic valve replacement (TAVR) has become the standard treatment for severe aortic stenosis and has shown comparable efficacy to traditional surgery in low and intermediate-risk patients. However, the bioprosthetic valves used in TAVR have a limited lifespan, and bioprosthetic valve failure, including calcification, rupture or infection may develop, leading to poor clinical outcomes. Elevated blood pressure has been identified as a key factor in aortic valve calcification, and its role in bioprosthetic valve failure is gaining increasing attention. Hypertension may accelerate the calcification process and exacerbate valve failure due to increased mechanical stress on the valve, activation of the renin-angiotensin system, and enhanced thrombus formation. Furthermore, elevated blood pressure interacts with prosthesis mismatch and paravalvular leak, jointly affecting valve durability. This review explores the impact of elevated blood pressure on bioprosthetic valve calcification and failure after TAVR, and emphases the importance of blood pressure control, optimized preoperative assessment, and appropriate valve selection in reducing valve failure.</p>","PeriodicalId":24007,"journal":{"name":"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences","volume":" ","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of elevated arterial blood pressure on the calcification and failure of bioprosthetic valve after transcatheter aortic valve replacement.\",\"authors\":\"Wenjing Sheng, Qifeng Zhu, Hanyi Dai, Dao Zhou, Xianbao Liu\",\"doi\":\"10.3724/zdxbyxb-2024-0391\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Transcatheter aortic valve replacement (TAVR) has become the standard treatment for severe aortic stenosis and has shown comparable efficacy to traditional surgery in low and intermediate-risk patients. However, the bioprosthetic valves used in TAVR have a limited lifespan, and bioprosthetic valve failure, including calcification, rupture or infection may develop, leading to poor clinical outcomes. Elevated blood pressure has been identified as a key factor in aortic valve calcification, and its role in bioprosthetic valve failure is gaining increasing attention. Hypertension may accelerate the calcification process and exacerbate valve failure due to increased mechanical stress on the valve, activation of the renin-angiotensin system, and enhanced thrombus formation. Furthermore, elevated blood pressure interacts with prosthesis mismatch and paravalvular leak, jointly affecting valve durability. This review explores the impact of elevated blood pressure on bioprosthetic valve calcification and failure after TAVR, and emphases the importance of blood pressure control, optimized preoperative assessment, and appropriate valve selection in reducing valve failure.</p>\",\"PeriodicalId\":24007,\"journal\":{\"name\":\"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences\",\"volume\":\" \",\"pages\":\"1-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3724/zdxbyxb-2024-0391\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/zdxbyxb-2024-0391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Impact of elevated arterial blood pressure on the calcification and failure of bioprosthetic valve after transcatheter aortic valve replacement.
Transcatheter aortic valve replacement (TAVR) has become the standard treatment for severe aortic stenosis and has shown comparable efficacy to traditional surgery in low and intermediate-risk patients. However, the bioprosthetic valves used in TAVR have a limited lifespan, and bioprosthetic valve failure, including calcification, rupture or infection may develop, leading to poor clinical outcomes. Elevated blood pressure has been identified as a key factor in aortic valve calcification, and its role in bioprosthetic valve failure is gaining increasing attention. Hypertension may accelerate the calcification process and exacerbate valve failure due to increased mechanical stress on the valve, activation of the renin-angiotensin system, and enhanced thrombus formation. Furthermore, elevated blood pressure interacts with prosthesis mismatch and paravalvular leak, jointly affecting valve durability. This review explores the impact of elevated blood pressure on bioprosthetic valve calcification and failure after TAVR, and emphases the importance of blood pressure control, optimized preoperative assessment, and appropriate valve selection in reducing valve failure.