在不同化学成分的牙科铸造树脂中,快速成型可摘模具的尺寸稳定性和配合度。

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Fiona Cornelia Arnold, Dr Mustafa Borga Dönmez, Hanan Al-Johani, Çiğdem Kahveci, Martin Schimmel, Burak Yilmaz, Gülce Çakmak
{"title":"在不同化学成分的牙科铸造树脂中,快速成型可摘模具的尺寸稳定性和配合度。","authors":"Fiona Cornelia Arnold, Dr Mustafa Borga Dönmez, Hanan Al-Johani, Çiğdem Kahveci, Martin Schimmel, Burak Yilmaz, Gülce Çakmak","doi":"10.1016/j.prosdent.2025.02.045","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Additive manufacturing has enabled the fabrication of removable dies in various resins with different compositions. However, the knowledge on the dimensional stability and fit of removable dies fabricated with different dental cast resins is lacking.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to evaluate the effect of dental cast resin type and storage time on the dimensional stability and fit of AM removable dies throughout a 4-week period.</p><p><strong>Material and methods: </strong>A typodont model with a prepared right first mandibular molar was digitized with an intraoral scanner (IOS) (CEREC Primescan) to generate a standard tessellation language (STL) file. The STL file was imported into a dental design software program to design a removable die with 10-degree shaft taper angle and a hollow partial arch cast with and without the die. The removable die and hollow partial arch cast without the die STLs were used to additively manufacture 48 removable dies (n=16) and 3 hollow casts (n=1) by using a dental cast resin (DentaMODEL) (AM-DM), a bio-based dental cast resin (FotoDent biobased model) (AM-FD), and a nanographene-reinforced dental cast resin (G-Print) (AM-GP). The same IOS was used to digitize each die and when the die was seated into its respective hollow cast 1 day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. All STL files were imported into a metrology-grade 3-dimensional analysis software program (Geomagic Control X). The root mean square (RMS) was used to assess deviations in different die regions (crown, root, base of the root, and overall) over 4 weeks, along with fit evaluation by calculating RMS for the crown portion within the cast and measuring mean distance deviations at 5 points on the die. The generalized linear model analysis and Bonferroni-corrected post hoc tests were used to evaluate the data (α=.05).</p><p><strong>Results: </strong>The dimensional stability of the removable dies was affected by the interaction between resin type and die region and by the interaction between the resin type and time point, while the fit of the dies was impacted by the interaction between resin type and time point (P<.001). AM-GP dies mostly had higher crown RMS than AM-FD dies (P<.001), while AM-DM dies had the highest root and base of the root RMS (P≤.027). AM-FD dies had the lowest overall RMS (P≤.038). The base of the root led to the highest RMS for each resin (P<.001). AM-FD dies had lower RMS than AM-GP at T0 and AM-DM at T2, while AM-GP dies had lower RMS than AM-DM at T1 (P≤.010). The RMS values of AM-GP dies were lower at T1 than at T0 and T3 (P<.001). When the fit of the dies was considered, AM-FD dies had the lowest and AM-DM dies had the highest crown portion RMS and point-based deviations at each time point (P<.001). In addition, AM-DM dies' RMS values and deviations were the lowest at T0, while AM-FD dies had the highest point-based deviations at T4 (P≤.034).</p><p><strong>Conclusions: </strong>Within tested regions and time points, AM-FD dies mostly had higher dimensional stability and better fit. Therefore, the crowns to be adjusted on AM-FD dies may require fewer interproximal and occlusal adjustments.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dimensional stability and fit of additively manufactured removable dies in dental cast resins with different chemical compositions.\",\"authors\":\"Fiona Cornelia Arnold, Dr Mustafa Borga Dönmez, Hanan Al-Johani, Çiğdem Kahveci, Martin Schimmel, Burak Yilmaz, Gülce Çakmak\",\"doi\":\"10.1016/j.prosdent.2025.02.045\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Statement of problem: </strong>Additive manufacturing has enabled the fabrication of removable dies in various resins with different compositions. However, the knowledge on the dimensional stability and fit of removable dies fabricated with different dental cast resins is lacking.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to evaluate the effect of dental cast resin type and storage time on the dimensional stability and fit of AM removable dies throughout a 4-week period.</p><p><strong>Material and methods: </strong>A typodont model with a prepared right first mandibular molar was digitized with an intraoral scanner (IOS) (CEREC Primescan) to generate a standard tessellation language (STL) file. The STL file was imported into a dental design software program to design a removable die with 10-degree shaft taper angle and a hollow partial arch cast with and without the die. The removable die and hollow partial arch cast without the die STLs were used to additively manufacture 48 removable dies (n=16) and 3 hollow casts (n=1) by using a dental cast resin (DentaMODEL) (AM-DM), a bio-based dental cast resin (FotoDent biobased model) (AM-FD), and a nanographene-reinforced dental cast resin (G-Print) (AM-GP). The same IOS was used to digitize each die and when the die was seated into its respective hollow cast 1 day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. All STL files were imported into a metrology-grade 3-dimensional analysis software program (Geomagic Control X). The root mean square (RMS) was used to assess deviations in different die regions (crown, root, base of the root, and overall) over 4 weeks, along with fit evaluation by calculating RMS for the crown portion within the cast and measuring mean distance deviations at 5 points on the die. The generalized linear model analysis and Bonferroni-corrected post hoc tests were used to evaluate the data (α=.05).</p><p><strong>Results: </strong>The dimensional stability of the removable dies was affected by the interaction between resin type and die region and by the interaction between the resin type and time point, while the fit of the dies was impacted by the interaction between resin type and time point (P<.001). AM-GP dies mostly had higher crown RMS than AM-FD dies (P<.001), while AM-DM dies had the highest root and base of the root RMS (P≤.027). AM-FD dies had the lowest overall RMS (P≤.038). The base of the root led to the highest RMS for each resin (P<.001). AM-FD dies had lower RMS than AM-GP at T0 and AM-DM at T2, while AM-GP dies had lower RMS than AM-DM at T1 (P≤.010). The RMS values of AM-GP dies were lower at T1 than at T0 and T3 (P<.001). When the fit of the dies was considered, AM-FD dies had the lowest and AM-DM dies had the highest crown portion RMS and point-based deviations at each time point (P<.001). In addition, AM-DM dies' RMS values and deviations were the lowest at T0, while AM-FD dies had the highest point-based deviations at T4 (P≤.034).</p><p><strong>Conclusions: </strong>Within tested regions and time points, AM-FD dies mostly had higher dimensional stability and better fit. Therefore, the crowns to be adjusted on AM-FD dies may require fewer interproximal and occlusal adjustments.</p>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2025-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.prosdent.2025.02.045\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2025.02.045","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dimensional stability and fit of additively manufactured removable dies in dental cast resins with different chemical compositions.

Statement of problem: Additive manufacturing has enabled the fabrication of removable dies in various resins with different compositions. However, the knowledge on the dimensional stability and fit of removable dies fabricated with different dental cast resins is lacking.

Purpose: The purpose of this in vitro study was to evaluate the effect of dental cast resin type and storage time on the dimensional stability and fit of AM removable dies throughout a 4-week period.

Material and methods: A typodont model with a prepared right first mandibular molar was digitized with an intraoral scanner (IOS) (CEREC Primescan) to generate a standard tessellation language (STL) file. The STL file was imported into a dental design software program to design a removable die with 10-degree shaft taper angle and a hollow partial arch cast with and without the die. The removable die and hollow partial arch cast without the die STLs were used to additively manufacture 48 removable dies (n=16) and 3 hollow casts (n=1) by using a dental cast resin (DentaMODEL) (AM-DM), a bio-based dental cast resin (FotoDent biobased model) (AM-FD), and a nanographene-reinforced dental cast resin (G-Print) (AM-GP). The same IOS was used to digitize each die and when the die was seated into its respective hollow cast 1 day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. All STL files were imported into a metrology-grade 3-dimensional analysis software program (Geomagic Control X). The root mean square (RMS) was used to assess deviations in different die regions (crown, root, base of the root, and overall) over 4 weeks, along with fit evaluation by calculating RMS for the crown portion within the cast and measuring mean distance deviations at 5 points on the die. The generalized linear model analysis and Bonferroni-corrected post hoc tests were used to evaluate the data (α=.05).

Results: The dimensional stability of the removable dies was affected by the interaction between resin type and die region and by the interaction between the resin type and time point, while the fit of the dies was impacted by the interaction between resin type and time point (P<.001). AM-GP dies mostly had higher crown RMS than AM-FD dies (P<.001), while AM-DM dies had the highest root and base of the root RMS (P≤.027). AM-FD dies had the lowest overall RMS (P≤.038). The base of the root led to the highest RMS for each resin (P<.001). AM-FD dies had lower RMS than AM-GP at T0 and AM-DM at T2, while AM-GP dies had lower RMS than AM-DM at T1 (P≤.010). The RMS values of AM-GP dies were lower at T1 than at T0 and T3 (P<.001). When the fit of the dies was considered, AM-FD dies had the lowest and AM-DM dies had the highest crown portion RMS and point-based deviations at each time point (P<.001). In addition, AM-DM dies' RMS values and deviations were the lowest at T0, while AM-FD dies had the highest point-based deviations at T4 (P≤.034).

Conclusions: Within tested regions and time points, AM-FD dies mostly had higher dimensional stability and better fit. Therefore, the crowns to be adjusted on AM-FD dies may require fewer interproximal and occlusal adjustments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信