IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Andrea Cabrero-Martín, Sara Santiago, Verónica Serafín, María Pedrero, Ana Montero-Calle, José M. Pingarrón, Rodrigo Barderas, Susana Campuzano
{"title":"Multifunctional cerium nanolabels in electrochemical immunosensing with improved robustness and performance: determination of TIM-1 in colorectal cancer scenarios as a case study","authors":"Andrea Cabrero-Martín,&nbsp;Sara Santiago,&nbsp;Verónica Serafín,&nbsp;María Pedrero,&nbsp;Ana Montero-Calle,&nbsp;José M. Pingarrón,&nbsp;Rodrigo Barderas,&nbsp;Susana Campuzano","doi":"10.1007/s00604-025-07021-3","DOIUrl":null,"url":null,"abstract":"<div><p>A multifunctional cerium oxide nanoparticles (CeO<sub>2</sub>NPs)-based nanolabel is exploited to implement an electrochemical sandwich-type immunoplatform for the determination of T-cell immunoglobulin and mucin domain 1 (TIM-1) biomarker, a mucin-like class I membrane glycoprotein associated with cancer angiogenesis. The immunoplatform is constructed using screen-printed electrodes where capture antibody is immobilized through the chemistry of diazonium salts. CeO<sub>2</sub>NPs exhibit robust pseudo-peroxidase activity even at high substrate concentrations. They are covalently functionalized in a simple manner after carboxylation with a detector antibody (dAb), acting dually as a nanozyme and nanocarrier for sensing bioreceptors. This allows the development of immunoplatforms with improved robustness and performance (in terms of a moderate enhancement in sensitivity, a significant expansion in the linear range, and a reduction in the background current) compared with the immunoplatforms prepared using nanolabels also decorated with the natural enzyme (horseradish peroxidase, HRP) or the conventional enzymatic labeling involving the dAb and an HRP-secondary antibody. Under the optimized experimental conditions, the developed electrochemical immunoplatform allows the highly sensitive detection of the TIM-1 glycoprotein, with a detection limit of 9.9 pg mL<sup>−1</sup> and a linear working range of 33–600 pg mL<sup>−1</sup>. This performance permits biomarker quantification within clinically relevant ranges. This innovative configuration enables the precise diagnosis and stratification of colorectal cancer patients by analyzing plasma samples without pretreatment beyond a sample dilution and allows establishment of the first cut-off values reported for this purpose.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 4","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-025-07021-3","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

利用一种基于多功能氧化铈纳米颗粒(CeO2NPs)的纳米标记物,实现了一种电化学夹心型免疫平台,用于检测 T 细胞免疫球蛋白和粘蛋白结构域 1(TIM-1)生物标记物,TIM-1 是一种与癌症血管生成相关的粘蛋白样 I 类膜糖蛋白。免疫平台采用丝网印刷电极构建,通过重氮盐的化学作用固定捕获抗体。CeO2NPs 即使在底物浓度很高的情况下也能表现出很强的伪过氧化物酶活性。它们在与检测抗体(dAb)进行羧化后,以简单的方式实现共价官能化,既是纳米酶,又是传感生物受体的纳米载体。与使用天然酶(辣根过氧化物酶,HRP)装饰的纳米标签或涉及 dAb 和 HRP 二级抗体的传统酶标记法制备的免疫平台相比,这种方法使免疫平台的稳健性和性能得到改善(灵敏度适度提高,线性范围显著扩大,背景电流降低)。在优化的实验条件下,所开发的电化学免疫平台能高灵敏地检测 TIM-1 糖蛋白,检测限为 9.9 pg mL-1,线性工作范围为 33-600 pg mL-1。这种性能允许在临床相关范围内对生物标记物进行定量。这种创新的配置无需对血浆样本进行稀释以外的预处理,就能对结直肠癌患者进行精确诊断和分层,并首次建立了用于此目的的临界值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multifunctional cerium nanolabels in electrochemical immunosensing with improved robustness and performance: determination of TIM-1 in colorectal cancer scenarios as a case study

A multifunctional cerium oxide nanoparticles (CeO2NPs)-based nanolabel is exploited to implement an electrochemical sandwich-type immunoplatform for the determination of T-cell immunoglobulin and mucin domain 1 (TIM-1) biomarker, a mucin-like class I membrane glycoprotein associated with cancer angiogenesis. The immunoplatform is constructed using screen-printed electrodes where capture antibody is immobilized through the chemistry of diazonium salts. CeO2NPs exhibit robust pseudo-peroxidase activity even at high substrate concentrations. They are covalently functionalized in a simple manner after carboxylation with a detector antibody (dAb), acting dually as a nanozyme and nanocarrier for sensing bioreceptors. This allows the development of immunoplatforms with improved robustness and performance (in terms of a moderate enhancement in sensitivity, a significant expansion in the linear range, and a reduction in the background current) compared with the immunoplatforms prepared using nanolabels also decorated with the natural enzyme (horseradish peroxidase, HRP) or the conventional enzymatic labeling involving the dAb and an HRP-secondary antibody. Under the optimized experimental conditions, the developed electrochemical immunoplatform allows the highly sensitive detection of the TIM-1 glycoprotein, with a detection limit of 9.9 pg mL−1 and a linear working range of 33–600 pg mL−1. This performance permits biomarker quantification within clinically relevant ranges. This innovative configuration enables the precise diagnosis and stratification of colorectal cancer patients by analyzing plasma samples without pretreatment beyond a sample dilution and allows establishment of the first cut-off values reported for this purpose.

Graphical abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信