印度患者下肢的股四头肌矢量与白种人和日本患者相似。

IF 3.4 2区 医学 Q1 ORTHOPEDICS
Fangzhou Chi, Shigeru Takagi, Tomoharu Mochizuki, Hiroyuki Kawashima, Rajesh Malhotra, J David Blaha
{"title":"印度患者下肢的股四头肌矢量与白种人和日本患者相似。","authors":"Fangzhou Chi, Shigeru Takagi, Tomoharu Mochizuki, Hiroyuki Kawashima, Rajesh Malhotra, J David Blaha","doi":"10.1016/j.arth.2025.03.020","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Correct alignment of knee components contributes to the longevity and function of total knee arthroplasty. The accuracy and reliability of calculating the three-dimensional quadriceps vector (QV) using computed tomography (CT) scans in Caucasian and Japanese study participants have been established in previous studies. In all cases, the QV was directed from the top of the patella to the middle of the femoral neck. The literature describes considerable differences in the morphology of bone in the lower extremities of Indian people compared with that of Caucasian and Japanese people.</p><p><strong>Methods: </strong>An imaging study was conducted using CT scans to determine the QV in a cohort of 36 patients from India [18 women (mean age 59 years), 18 men (mean age 61 years)]. The same measurement methods were used for this cohort as in previous studies. The QV and all measured axes were compared within the cohort.</p><p><strong>Results: </strong>The QV for the Indian cohort was found to be directed from the top of the patella toward the femoral neck, as in Caucasian and Japanese CT scans. In the Indian knees, the passing point of the vector was found to be lateral 30.8 mm (range, 25.2 to 36.4) and anterior 31.2 mm (range, 28.4 to 33.9) to the femoral head. When projected to the coronal plane, the QV was closest to that of the spherical axis, 1.2 ± 0.8° (P < 0.05).</p><p><strong>Conclusion: </strong>As in previous studies, the QV crosses the femoral neck lateral to the femoral head and is most parallel to the spherical axis (center femoral head to center spherical medial condyle) projected onto the coronal plane in the native Indian knee. These data suggest that using the QV for alignment may be applied to most human knees regardless of morphology.</p>","PeriodicalId":51077,"journal":{"name":"Journal of Arthroplasty","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Quadriceps Vector in the Lower Extremity of Indian Patients is Similar in Caucasian and Japanese Patients.\",\"authors\":\"Fangzhou Chi, Shigeru Takagi, Tomoharu Mochizuki, Hiroyuki Kawashima, Rajesh Malhotra, J David Blaha\",\"doi\":\"10.1016/j.arth.2025.03.020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Correct alignment of knee components contributes to the longevity and function of total knee arthroplasty. The accuracy and reliability of calculating the three-dimensional quadriceps vector (QV) using computed tomography (CT) scans in Caucasian and Japanese study participants have been established in previous studies. In all cases, the QV was directed from the top of the patella to the middle of the femoral neck. The literature describes considerable differences in the morphology of bone in the lower extremities of Indian people compared with that of Caucasian and Japanese people.</p><p><strong>Methods: </strong>An imaging study was conducted using CT scans to determine the QV in a cohort of 36 patients from India [18 women (mean age 59 years), 18 men (mean age 61 years)]. The same measurement methods were used for this cohort as in previous studies. The QV and all measured axes were compared within the cohort.</p><p><strong>Results: </strong>The QV for the Indian cohort was found to be directed from the top of the patella toward the femoral neck, as in Caucasian and Japanese CT scans. In the Indian knees, the passing point of the vector was found to be lateral 30.8 mm (range, 25.2 to 36.4) and anterior 31.2 mm (range, 28.4 to 33.9) to the femoral head. When projected to the coronal plane, the QV was closest to that of the spherical axis, 1.2 ± 0.8° (P < 0.05).</p><p><strong>Conclusion: </strong>As in previous studies, the QV crosses the femoral neck lateral to the femoral head and is most parallel to the spherical axis (center femoral head to center spherical medial condyle) projected onto the coronal plane in the native Indian knee. These data suggest that using the QV for alignment may be applied to most human knees regardless of morphology.</p>\",\"PeriodicalId\":51077,\"journal\":{\"name\":\"Journal of Arthroplasty\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2025-03-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Arthroplasty\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.arth.2025.03.020\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arthroplasty","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.arth.2025.03.020","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

导言:膝关节各部件的正确对齐有助于全膝关节置换术的寿命和功能。在以前的研究中,使用计算机断层扫描(CT)计算高加索和日本研究参与者的三维四头肌矢量(QV)的准确性和可靠性已经建立。在所有病例中,QV从髌骨顶部指向股骨颈中部。文献描述了印度人与白种人和日本人相比,在下肢骨骼形态上有相当大的差异。方法:对来自印度的36例患者(18例女性(平均59岁),18例男性(平均61岁))进行CT扫描以确定QV的影像学研究。本研究采用了与以往研究相同的测量方法。在队列中比较QV和所有测量轴。结果:与高加索人和日本人的CT扫描一样,印度队列的QV从髌骨顶部指向股骨颈。在印度膝,矢量的通过点位于股骨头外侧30.8 mm(范围,25.2至36.4)和前方31.2 mm(范围,28.4至33.9)。在冠状面投影时,QV与球轴最接近,为1.2±0.8°(P < 0.05)。结论:与先前的研究一样,QV穿过股骨头外侧的股骨颈,最平行于印度膝冠状面投影的球形轴(股骨头中心到球形内髁中心)。这些数据表明,无论形态如何,使用QV进行对齐可能适用于大多数人的膝盖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Quadriceps Vector in the Lower Extremity of Indian Patients is Similar in Caucasian and Japanese Patients.

Introduction: Correct alignment of knee components contributes to the longevity and function of total knee arthroplasty. The accuracy and reliability of calculating the three-dimensional quadriceps vector (QV) using computed tomography (CT) scans in Caucasian and Japanese study participants have been established in previous studies. In all cases, the QV was directed from the top of the patella to the middle of the femoral neck. The literature describes considerable differences in the morphology of bone in the lower extremities of Indian people compared with that of Caucasian and Japanese people.

Methods: An imaging study was conducted using CT scans to determine the QV in a cohort of 36 patients from India [18 women (mean age 59 years), 18 men (mean age 61 years)]. The same measurement methods were used for this cohort as in previous studies. The QV and all measured axes were compared within the cohort.

Results: The QV for the Indian cohort was found to be directed from the top of the patella toward the femoral neck, as in Caucasian and Japanese CT scans. In the Indian knees, the passing point of the vector was found to be lateral 30.8 mm (range, 25.2 to 36.4) and anterior 31.2 mm (range, 28.4 to 33.9) to the femoral head. When projected to the coronal plane, the QV was closest to that of the spherical axis, 1.2 ± 0.8° (P < 0.05).

Conclusion: As in previous studies, the QV crosses the femoral neck lateral to the femoral head and is most parallel to the spherical axis (center femoral head to center spherical medial condyle) projected onto the coronal plane in the native Indian knee. These data suggest that using the QV for alignment may be applied to most human knees regardless of morphology.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Arthroplasty
Journal of Arthroplasty 医学-整形外科
CiteScore
7.00
自引率
20.00%
发文量
734
审稿时长
48 days
期刊介绍: The Journal of Arthroplasty brings together the clinical and scientific foundations for joint replacement. This peer-reviewed journal publishes original research and manuscripts of the highest quality from all areas relating to joint replacement or the treatment of its complications, including those dealing with clinical series and experience, prosthetic design, biomechanics, biomaterials, metallurgy, biologic response to arthroplasty materials in vivo and in vitro.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信