不同杜仲胶去除技术对牙本质完整性的影响:体外分析。

Q2 Dentistry
Orlando Aguirre Guedes, Henrique Carneiro Ferreira, Danielly Moreira Abreu, Kássia Sousa de Lima, Esther Menezes Souza, Yasmin Gomes de Freitas, Daniel de Almeida Decurcio, Carlos Estrela
{"title":"不同杜仲胶去除技术对牙本质完整性的影响:体外分析。","authors":"Orlando Aguirre Guedes, Henrique Carneiro Ferreira, Danielly Moreira Abreu, Kássia Sousa de Lima, Esther Menezes Souza, Yasmin Gomes de Freitas, Daniel de Almeida Decurcio, Carlos Estrela","doi":"10.4317/jced.62524","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to evaluate the impact of different gutta-percha removal (GPR) techniques on the occurrence of dentinal defects in bovine root canals.</p><p><strong>Material and methods: </strong>One hundred and eight bovine incisors were selected and stored in distilled water. The crowns were removed, leaving roots approximately 17 mm in length. Twelve roots were left unprepared and served as control (G1), and the remaining 96 roots were instrumented with BioRace files up to size 40/.04 (BR5) and filled with gutta-percha and Sealapex sealer using the lateral condensation technique. Twelve other roots were left filled and received no retreatment procedure (G2). The remaining 84 roots underwent filling material removal with R-Endo (G3), D-Race (G4), WaveOne Gold (G5), ProTaper Retreatment (G6), Mtwo R (G7), Reciproc (G8) instruments or with R1-Clearsonic ultrasonic insert (G9). After GPR, final apical enlargement was achieved using a BR7 (#60/.02) instrument. Roots were sectioned 3, 6 and 9 mm from the apex and observed under a stereomicroscope at 25ᵡ magnification. The presence/absence of root fractures, microcracks, and craze lines were recorded. Chi-square tests compared the incidence of dentinal defects between the groups, with a significance level set at <i>P</i><.05.</p><p><strong>Results: </strong>Defects occurred in 46.6% of the samples. No defects were observed in the unprepared canals (control, G1). Defects were detected in all other experimental groups (G2 to G9). Among retreatment techniques the R-Endo group (G3) presented significantly higher microcracks and craze lines (<i>P</i><.05). Defects were more frequent in the coronal and middle thirds.</p><p><strong>Conclusions: </strong>All GPR methods were linked to dentinal defects. The R-Endo system significantly increased microcracks and craze lines. <b>Key words:</b>Cracks, Dentinal defects, Gutta-percha removal, Retreatment, Vertical root fracture.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"17 2","pages":"e195-e203"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11907345/pdf/","citationCount":"0","resultStr":"{\"title\":\"Impact of different gutta-percha removal techniques on dentinal integrity: An <i>in vitro</i> analysis.\",\"authors\":\"Orlando Aguirre Guedes, Henrique Carneiro Ferreira, Danielly Moreira Abreu, Kássia Sousa de Lima, Esther Menezes Souza, Yasmin Gomes de Freitas, Daniel de Almeida Decurcio, Carlos Estrela\",\"doi\":\"10.4317/jced.62524\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>This study aimed to evaluate the impact of different gutta-percha removal (GPR) techniques on the occurrence of dentinal defects in bovine root canals.</p><p><strong>Material and methods: </strong>One hundred and eight bovine incisors were selected and stored in distilled water. The crowns were removed, leaving roots approximately 17 mm in length. Twelve roots were left unprepared and served as control (G1), and the remaining 96 roots were instrumented with BioRace files up to size 40/.04 (BR5) and filled with gutta-percha and Sealapex sealer using the lateral condensation technique. Twelve other roots were left filled and received no retreatment procedure (G2). The remaining 84 roots underwent filling material removal with R-Endo (G3), D-Race (G4), WaveOne Gold (G5), ProTaper Retreatment (G6), Mtwo R (G7), Reciproc (G8) instruments or with R1-Clearsonic ultrasonic insert (G9). After GPR, final apical enlargement was achieved using a BR7 (#60/.02) instrument. Roots were sectioned 3, 6 and 9 mm from the apex and observed under a stereomicroscope at 25ᵡ magnification. The presence/absence of root fractures, microcracks, and craze lines were recorded. Chi-square tests compared the incidence of dentinal defects between the groups, with a significance level set at <i>P</i><.05.</p><p><strong>Results: </strong>Defects occurred in 46.6% of the samples. No defects were observed in the unprepared canals (control, G1). Defects were detected in all other experimental groups (G2 to G9). Among retreatment techniques the R-Endo group (G3) presented significantly higher microcracks and craze lines (<i>P</i><.05). Defects were more frequent in the coronal and middle thirds.</p><p><strong>Conclusions: </strong>All GPR methods were linked to dentinal defects. The R-Endo system significantly increased microcracks and craze lines. <b>Key words:</b>Cracks, Dentinal defects, Gutta-percha removal, Retreatment, Vertical root fracture.</p>\",\"PeriodicalId\":15376,\"journal\":{\"name\":\"Journal of Clinical and Experimental Dentistry\",\"volume\":\"17 2\",\"pages\":\"e195-e203\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11907345/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical and Experimental Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4317/jced.62524\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.62524","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究旨在评估不同的杜仲胶去除(GPR)技术对牛根管牙本质缺损发生的影响。材料与方法:选择牛门牙108颗,用蒸馏水保存。冠被移除,留下大约17毫米长的根。12根根未做好准备,作为对照(G1),其余96根根用BioRace文件检测,文件大小为40/ 0.04(BR5)和填充杜仲胶和Sealapex封口剂使用侧凝技术。其余12根被填充物,不进行再处理(G2)。其余84根采用R- endo (G3)、D-Race (G4)、WaveOne Gold (G5)、ProTaper Retreatment (G6)、Mtwo R (G7)、Reciproc (G8)器械或R1-Clearsonic超声植入物(G9)进行充填材料去除。GPR后,使用BR7(#60/.02)器械实现根尖扩大。根距根尖3、6和9 mm,在25倍显微镜下观察。记录了根断裂、微裂纹和裂纹线的存在/不存在。卡方检验比较各组之间牙本质缺陷的发生率,显著性水平设置为结果:46.6%的样本发生缺陷。在未准备的管道中未观察到缺陷(对照组,G1)。其他实验组(G2 ~ G9)均有缺陷。在再治疗方法中,R-Endo组(G3)出现了更高的微裂纹和裂纹线(p)。R-Endo系统显著增加了微裂纹和裂纹线。关键词:裂纹,牙本质缺陷,杜仲胶去除,再治疗,牙根纵裂
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of different gutta-percha removal techniques on dentinal integrity: An in vitro analysis.

Background: This study aimed to evaluate the impact of different gutta-percha removal (GPR) techniques on the occurrence of dentinal defects in bovine root canals.

Material and methods: One hundred and eight bovine incisors were selected and stored in distilled water. The crowns were removed, leaving roots approximately 17 mm in length. Twelve roots were left unprepared and served as control (G1), and the remaining 96 roots were instrumented with BioRace files up to size 40/.04 (BR5) and filled with gutta-percha and Sealapex sealer using the lateral condensation technique. Twelve other roots were left filled and received no retreatment procedure (G2). The remaining 84 roots underwent filling material removal with R-Endo (G3), D-Race (G4), WaveOne Gold (G5), ProTaper Retreatment (G6), Mtwo R (G7), Reciproc (G8) instruments or with R1-Clearsonic ultrasonic insert (G9). After GPR, final apical enlargement was achieved using a BR7 (#60/.02) instrument. Roots were sectioned 3, 6 and 9 mm from the apex and observed under a stereomicroscope at 25ᵡ magnification. The presence/absence of root fractures, microcracks, and craze lines were recorded. Chi-square tests compared the incidence of dentinal defects between the groups, with a significance level set at P<.05.

Results: Defects occurred in 46.6% of the samples. No defects were observed in the unprepared canals (control, G1). Defects were detected in all other experimental groups (G2 to G9). Among retreatment techniques the R-Endo group (G3) presented significantly higher microcracks and craze lines (P<.05). Defects were more frequent in the coronal and middle thirds.

Conclusions: All GPR methods were linked to dentinal defects. The R-Endo system significantly increased microcracks and craze lines. Key words:Cracks, Dentinal defects, Gutta-percha removal, Retreatment, Vertical root fracture.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
118
期刊介绍: Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信