用于测量软性微型样品硬度的无创全息传感器系统。

IF 3 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Journal of Biomedical Optics Pub Date : 2025-03-01 Epub Date: 2025-03-14 DOI:10.1117/1.JBO.30.3.036501
Hasan Berkay Abdioğlu, Yağmur Işık, Merve Sevgi, Ali Anil Demircali, Ufuk Gorkem Kirabali, Gokhan Bora Esmer, Huseyin Uvet
{"title":"用于测量软性微型样品硬度的无创全息传感器系统。","authors":"Hasan Berkay Abdioğlu, Yağmur Işık, Merve Sevgi, Ali Anil Demircali, Ufuk Gorkem Kirabali, Gokhan Bora Esmer, Huseyin Uvet","doi":"10.1117/1.JBO.30.3.036501","DOIUrl":null,"url":null,"abstract":"<p><p><b>Significance</b>: Measuring cell stiffness is essential in cellular biomechanics, particularly in understanding disease progression, including cancer metastasis and tissue mechanics. However, conventional techniques such as atomic force microscopy and optical stretching present limitations, including invasiveness, low throughput, and complex sample preparation. These factors restrict their applicability in dynamic and sensitive biological environments. <b>Aim</b>: This study introduces a noninvasive holographic sensor system for evaluating the stiffness of soft microscale samples. <b>Approach</b>: The proposed system integrates holographic imaging with acoustic stimulation using an off-axis Mach-Zehnder interferometer combined with bulk acoustic waves. This setup allows for label-free, high-throughput measurements while preserving sample integrity. The system was validated with polyacrylamide beads engineered to mimic cellular stiffness, ensuring precise and repeatable stiffness assessments. <b>Results</b>: Measurement errors caused by spatial variations were minimized through a structured imaging approach and a calibration strategy, improving uniformity across different regions. These corrections enhanced the consistency and reliability of stiffness assessments. Experimental validation demonstrated stable stiffness measurements regardless of sample size variations. Repeatability tests further confirmed the system's robustness, producing consistent results across multiple trials. <b>Conclusion</b>: The findings highlight the potential of this holographic sensor system in advancing cell biomechanics research, cancer diagnostics, and mechanobiology. By offering a noninvasive, high-throughput alternative for mechanical property assessments in biological samples, this method contributes to improved characterization of cellular stiffness in biomedical applications.</p>","PeriodicalId":15264,"journal":{"name":"Journal of Biomedical Optics","volume":"30 3","pages":"036501"},"PeriodicalIF":3.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11907929/pdf/","citationCount":"0","resultStr":"{\"title\":\"Noninvasive holographic sensor system for measuring stiffness of soft micro samples.\",\"authors\":\"Hasan Berkay Abdioğlu, Yağmur Işık, Merve Sevgi, Ali Anil Demircali, Ufuk Gorkem Kirabali, Gokhan Bora Esmer, Huseyin Uvet\",\"doi\":\"10.1117/1.JBO.30.3.036501\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Significance</b>: Measuring cell stiffness is essential in cellular biomechanics, particularly in understanding disease progression, including cancer metastasis and tissue mechanics. However, conventional techniques such as atomic force microscopy and optical stretching present limitations, including invasiveness, low throughput, and complex sample preparation. These factors restrict their applicability in dynamic and sensitive biological environments. <b>Aim</b>: This study introduces a noninvasive holographic sensor system for evaluating the stiffness of soft microscale samples. <b>Approach</b>: The proposed system integrates holographic imaging with acoustic stimulation using an off-axis Mach-Zehnder interferometer combined with bulk acoustic waves. This setup allows for label-free, high-throughput measurements while preserving sample integrity. The system was validated with polyacrylamide beads engineered to mimic cellular stiffness, ensuring precise and repeatable stiffness assessments. <b>Results</b>: Measurement errors caused by spatial variations were minimized through a structured imaging approach and a calibration strategy, improving uniformity across different regions. These corrections enhanced the consistency and reliability of stiffness assessments. Experimental validation demonstrated stable stiffness measurements regardless of sample size variations. Repeatability tests further confirmed the system's robustness, producing consistent results across multiple trials. <b>Conclusion</b>: The findings highlight the potential of this holographic sensor system in advancing cell biomechanics research, cancer diagnostics, and mechanobiology. By offering a noninvasive, high-throughput alternative for mechanical property assessments in biological samples, this method contributes to improved characterization of cellular stiffness in biomedical applications.</p>\",\"PeriodicalId\":15264,\"journal\":{\"name\":\"Journal of Biomedical Optics\",\"volume\":\"30 3\",\"pages\":\"036501\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11907929/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomedical Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JBO.30.3.036501\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JBO.30.3.036501","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Noninvasive holographic sensor system for measuring stiffness of soft micro samples.

Significance: Measuring cell stiffness is essential in cellular biomechanics, particularly in understanding disease progression, including cancer metastasis and tissue mechanics. However, conventional techniques such as atomic force microscopy and optical stretching present limitations, including invasiveness, low throughput, and complex sample preparation. These factors restrict their applicability in dynamic and sensitive biological environments. Aim: This study introduces a noninvasive holographic sensor system for evaluating the stiffness of soft microscale samples. Approach: The proposed system integrates holographic imaging with acoustic stimulation using an off-axis Mach-Zehnder interferometer combined with bulk acoustic waves. This setup allows for label-free, high-throughput measurements while preserving sample integrity. The system was validated with polyacrylamide beads engineered to mimic cellular stiffness, ensuring precise and repeatable stiffness assessments. Results: Measurement errors caused by spatial variations were minimized through a structured imaging approach and a calibration strategy, improving uniformity across different regions. These corrections enhanced the consistency and reliability of stiffness assessments. Experimental validation demonstrated stable stiffness measurements regardless of sample size variations. Repeatability tests further confirmed the system's robustness, producing consistent results across multiple trials. Conclusion: The findings highlight the potential of this holographic sensor system in advancing cell biomechanics research, cancer diagnostics, and mechanobiology. By offering a noninvasive, high-throughput alternative for mechanical property assessments in biological samples, this method contributes to improved characterization of cellular stiffness in biomedical applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.40
自引率
5.70%
发文量
263
审稿时长
2 months
期刊介绍: The Journal of Biomedical Optics publishes peer-reviewed papers on the use of modern optical technology for improved health care and biomedical research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信