Marsha S Santoso, Eggi Arguni, Bunga Rana, Mercy E Adiniko, Dionisius Denis, Endah Supriyati, Citra Indriani, Leily Trianty, Riris Andono Ahmad, Rintis Noviyanti, R Tedjo Sasmono
{"title":"敏感性和特异性的一体化Cartridge-Based登革热实时rt - pcr快速检测和血清型登革病毒的样本印尼病人。","authors":"Marsha S Santoso, Eggi Arguni, Bunga Rana, Mercy E Adiniko, Dionisius Denis, Endah Supriyati, Citra Indriani, Leily Trianty, Riris Andono Ahmad, Rintis Noviyanti, R Tedjo Sasmono","doi":"10.3343/alm.2024.0558","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Dengue is a systemic, viral, mosquito-borne infection that continues to be a major public health issue in endemic regions in tropical and subtropical climates. Accurate tests for rapid diagnosis in point-of-care settings are important to reduce the fatality rates of severe dengue. We evaluated the diagnostic accuracy of the Standard M10 DENV 1-4 system (SD Biosensor, Gyeonggi, Korea), which is a cartridge-based, automated system that integrates nucleic acid extraction, reverse transcription-PCR (RT-PCR) amplification, and detection of dengue virus (DENV) serotypes.</p><p><strong>Methods: </strong>This was a retrospective diagnostic evaluation study. The index test, Standard M10 DENV 1-4, was evaluated using 320 dengue-positive and 279 dengue-negative archived samples. The reference tests were a combination of Centers for Disease Control and Prevention (CDC) DENV 1-4 real-time RT-PCR, dengue NS1 antigen and IgM antibody detection, and DENV whole-genome sequencing.</p><p><strong>Results: </strong>The overall sensitivity and specificity of Standard M10 DENV 1-4 were 94% and 100%, respectively. By serotype, the highest sensitivity was 100% for DENV-1, and the lowest was 82% for DENV-4. The overall between the CDC RT-PCR dengue serotyping method and the Standard M10 DENV 1-4 was 95%. Standard M10 DENV 1-4 RT-PCR had comparable sensitivity and specificity to CDC DENV RT-PCR.</p><p><strong>Conclusions: </strong>Based on its commensurate performance to an established RT-PCR method combined with additional benefits of convenient storage and transport, easy use, and rapid processing, the Standard M10 DENV 1-4 system has potential for DENV detection and serotyping in point-of-care settings.</p>","PeriodicalId":8421,"journal":{"name":"Annals of Laboratory Medicine","volume":" ","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensitivity and Specificity of an All-in-One Cartridge-Based Dengue Real-Time RT-PCR for Point-of-Care Detection and Serotyping of Dengue Virus in Samples From Indonesian Patients.\",\"authors\":\"Marsha S Santoso, Eggi Arguni, Bunga Rana, Mercy E Adiniko, Dionisius Denis, Endah Supriyati, Citra Indriani, Leily Trianty, Riris Andono Ahmad, Rintis Noviyanti, R Tedjo Sasmono\",\"doi\":\"10.3343/alm.2024.0558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Dengue is a systemic, viral, mosquito-borne infection that continues to be a major public health issue in endemic regions in tropical and subtropical climates. Accurate tests for rapid diagnosis in point-of-care settings are important to reduce the fatality rates of severe dengue. We evaluated the diagnostic accuracy of the Standard M10 DENV 1-4 system (SD Biosensor, Gyeonggi, Korea), which is a cartridge-based, automated system that integrates nucleic acid extraction, reverse transcription-PCR (RT-PCR) amplification, and detection of dengue virus (DENV) serotypes.</p><p><strong>Methods: </strong>This was a retrospective diagnostic evaluation study. The index test, Standard M10 DENV 1-4, was evaluated using 320 dengue-positive and 279 dengue-negative archived samples. The reference tests were a combination of Centers for Disease Control and Prevention (CDC) DENV 1-4 real-time RT-PCR, dengue NS1 antigen and IgM antibody detection, and DENV whole-genome sequencing.</p><p><strong>Results: </strong>The overall sensitivity and specificity of Standard M10 DENV 1-4 were 94% and 100%, respectively. By serotype, the highest sensitivity was 100% for DENV-1, and the lowest was 82% for DENV-4. The overall between the CDC RT-PCR dengue serotyping method and the Standard M10 DENV 1-4 was 95%. Standard M10 DENV 1-4 RT-PCR had comparable sensitivity and specificity to CDC DENV RT-PCR.</p><p><strong>Conclusions: </strong>Based on its commensurate performance to an established RT-PCR method combined with additional benefits of convenient storage and transport, easy use, and rapid processing, the Standard M10 DENV 1-4 system has potential for DENV detection and serotyping in point-of-care settings.</p>\",\"PeriodicalId\":8421,\"journal\":{\"name\":\"Annals of Laboratory Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.0000,\"publicationDate\":\"2025-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Laboratory Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3343/alm.2024.0558\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3343/alm.2024.0558","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
Sensitivity and Specificity of an All-in-One Cartridge-Based Dengue Real-Time RT-PCR for Point-of-Care Detection and Serotyping of Dengue Virus in Samples From Indonesian Patients.
Background: Dengue is a systemic, viral, mosquito-borne infection that continues to be a major public health issue in endemic regions in tropical and subtropical climates. Accurate tests for rapid diagnosis in point-of-care settings are important to reduce the fatality rates of severe dengue. We evaluated the diagnostic accuracy of the Standard M10 DENV 1-4 system (SD Biosensor, Gyeonggi, Korea), which is a cartridge-based, automated system that integrates nucleic acid extraction, reverse transcription-PCR (RT-PCR) amplification, and detection of dengue virus (DENV) serotypes.
Methods: This was a retrospective diagnostic evaluation study. The index test, Standard M10 DENV 1-4, was evaluated using 320 dengue-positive and 279 dengue-negative archived samples. The reference tests were a combination of Centers for Disease Control and Prevention (CDC) DENV 1-4 real-time RT-PCR, dengue NS1 antigen and IgM antibody detection, and DENV whole-genome sequencing.
Results: The overall sensitivity and specificity of Standard M10 DENV 1-4 were 94% and 100%, respectively. By serotype, the highest sensitivity was 100% for DENV-1, and the lowest was 82% for DENV-4. The overall between the CDC RT-PCR dengue serotyping method and the Standard M10 DENV 1-4 was 95%. Standard M10 DENV 1-4 RT-PCR had comparable sensitivity and specificity to CDC DENV RT-PCR.
Conclusions: Based on its commensurate performance to an established RT-PCR method combined with additional benefits of convenient storage and transport, easy use, and rapid processing, the Standard M10 DENV 1-4 system has potential for DENV detection and serotyping in point-of-care settings.
期刊介绍:
Annals of Laboratory Medicine is the official journal of Korean Society for Laboratory Medicine. The journal title has been recently changed from the Korean Journal of Laboratory Medicine (ISSN, 1598-6535) from the January issue of 2012. The JCR 2017 Impact factor of Ann Lab Med was 1.916.