{"title":"电池材料x射线纳米层析定量分析的比较研究:从非原位到操作测量","authors":"Victor Vanpeene*,&nbsp;Olga Stamati,&nbsp;Cyril Guilloud,&nbsp;Rémi Tucoulou,&nbsp;Benjamin Holliger,&nbsp;Marion Chandesris,&nbsp;Sandrine Lyonnard and Julie Villanova*,&nbsp;","doi":"10.1021/acsnano.4c1641910.1021/acsnano.4c16419","DOIUrl":null,"url":null,"abstract":"<p >Improving battery materials calls for nondestructive techniques capable of delivering high-resolution microstructural information in real time. In this context, X-ray phase contrast nano-tomography is a technique of choice as it enables multiscale 3D characterization. In this study, we propose a feedback loop-integrated workflow for X-ray nano-tomography, based on systematic evaluation of six state-of-the-art battery anode and cathode materials to benchmark key procedures ensuring reliable, reproducible, quality-assessed characterization and subsequent 3D morphological quantification, thus avoiding potential bias in the scientific conclusions. As a result for this phase contrast technique, the sample size and energy used appear as key factors for the final resolution, which enhances imaging capabilities for separating the different material phases of the electrode microstructures. But, it is crucial to adapt these parameters to the materials in order to mitigate errors in the morphological parameter estimation. Moreover, an empirical law based on the heterogeneity and the average particle size distribution has been established to calculate the minimum representative elementary volume to be imaged, showing that volumes of 102 × 102 × 102 μm<sup>3</sup> (50 nm voxel size) are sufficiently representative for the six microstructures studied. Ultimately, guidelines have been established for in situ/<i>operando</i> X-ray nano-tomography measurements, with a proposed/validated in-house setup and cell design that preserve both the image resolution and electrochemistry. A detailed evaluation of the X-ray beam interaction is also presented, exploring the relationship between the dose received by the electrolyte and material and the reliable monitoring of electrochemistry and tomography.</p>","PeriodicalId":21,"journal":{"name":"ACS Nano","volume":"19 10","pages":"9994–10012 9994–10012"},"PeriodicalIF":16.0000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Study of the Quantitative Analysis of Battery Materials with X-ray Nano-tomography: From Ex Situ toward Operando Measurements\",\"authors\":\"Victor Vanpeene*,&nbsp;Olga Stamati,&nbsp;Cyril Guilloud,&nbsp;Rémi Tucoulou,&nbsp;Benjamin Holliger,&nbsp;Marion Chandesris,&nbsp;Sandrine Lyonnard and Julie Villanova*,&nbsp;\",\"doi\":\"10.1021/acsnano.4c1641910.1021/acsnano.4c16419\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Improving battery materials calls for nondestructive techniques capable of delivering high-resolution microstructural information in real time. In this context, X-ray phase contrast nano-tomography is a technique of choice as it enables multiscale 3D characterization. In this study, we propose a feedback loop-integrated workflow for X-ray nano-tomography, based on systematic evaluation of six state-of-the-art battery anode and cathode materials to benchmark key procedures ensuring reliable, reproducible, quality-assessed characterization and subsequent 3D morphological quantification, thus avoiding potential bias in the scientific conclusions. As a result for this phase contrast technique, the sample size and energy used appear as key factors for the final resolution, which enhances imaging capabilities for separating the different material phases of the electrode microstructures. But, it is crucial to adapt these parameters to the materials in order to mitigate errors in the morphological parameter estimation. Moreover, an empirical law based on the heterogeneity and the average particle size distribution has been established to calculate the minimum representative elementary volume to be imaged, showing that volumes of 102 × 102 × 102 μm<sup>3</sup> (50 nm voxel size) are sufficiently representative for the six microstructures studied. Ultimately, guidelines have been established for in situ/<i>operando</i> X-ray nano-tomography measurements, with a proposed/validated in-house setup and cell design that preserve both the image resolution and electrochemistry. A detailed evaluation of the X-ray beam interaction is also presented, exploring the relationship between the dose received by the electrolyte and material and the reliable monitoring of electrochemistry and tomography.</p>\",\"PeriodicalId\":21,\"journal\":{\"name\":\"ACS Nano\",\"volume\":\"19 10\",\"pages\":\"9994–10012 9994–10012\"},\"PeriodicalIF\":16.0000,\"publicationDate\":\"2025-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Nano\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acsnano.4c16419\",\"RegionNum\":1,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Nano","FirstCategoryId":"88","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsnano.4c16419","RegionNum":1,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

改进电池材料需要能够实时提供高分辨率微结构信息的无损技术。在这种情况下,x射线相衬纳米层析成像是一种选择技术,因为它可以实现多尺度3D表征。在这项研究中,我们提出了一个反馈回路集成的x射线纳米断层扫描工作流程,基于六种最先进的电池阳极和阴极材料的系统评估,以基准关键程序,确保可靠,可重复性,质量评估的表征和随后的3D形态量化,从而避免科学结论的潜在偏差。因此,对于这种相对比技术,样品大小和使用的能量成为最终分辨率的关键因素,这增强了分离电极微结构不同材料相的成像能力。但是,为了减少形态参数估计的误差,使这些参数适应材料是至关重要的。此外,基于非均质性和平均粒径分布,建立了计算可成像的最小代表性基本体积的经验规律,结果表明,102 × 102 × 102 μm3 (50 nm体素尺寸)的体积足以代表所研究的6种微观结构。最终,建立了原位/操作x射线纳米层析成像测量的指导方针,并提出/验证了内部设置和电池设计,以保持图像分辨率和电化学性能。详细评估了x射线束的相互作用,探讨了电解质和材料接受的剂量与电化学和断层扫描的可靠监测之间的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparative Study of the Quantitative Analysis of Battery Materials with X-ray Nano-tomography: From Ex Situ toward Operando Measurements

Comparative Study of the Quantitative Analysis of Battery Materials with X-ray Nano-tomography: From Ex Situ toward Operando Measurements

Improving battery materials calls for nondestructive techniques capable of delivering high-resolution microstructural information in real time. In this context, X-ray phase contrast nano-tomography is a technique of choice as it enables multiscale 3D characterization. In this study, we propose a feedback loop-integrated workflow for X-ray nano-tomography, based on systematic evaluation of six state-of-the-art battery anode and cathode materials to benchmark key procedures ensuring reliable, reproducible, quality-assessed characterization and subsequent 3D morphological quantification, thus avoiding potential bias in the scientific conclusions. As a result for this phase contrast technique, the sample size and energy used appear as key factors for the final resolution, which enhances imaging capabilities for separating the different material phases of the electrode microstructures. But, it is crucial to adapt these parameters to the materials in order to mitigate errors in the morphological parameter estimation. Moreover, an empirical law based on the heterogeneity and the average particle size distribution has been established to calculate the minimum representative elementary volume to be imaged, showing that volumes of 102 × 102 × 102 μm3 (50 nm voxel size) are sufficiently representative for the six microstructures studied. Ultimately, guidelines have been established for in situ/operando X-ray nano-tomography measurements, with a proposed/validated in-house setup and cell design that preserve both the image resolution and electrochemistry. A detailed evaluation of the X-ray beam interaction is also presented, exploring the relationship between the dose received by the electrolyte and material and the reliable monitoring of electrochemistry and tomography.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Nano
ACS Nano 工程技术-材料科学:综合
CiteScore
26.00
自引率
4.10%
发文量
1627
审稿时长
1.7 months
期刊介绍: ACS Nano, published monthly, serves as an international forum for comprehensive articles on nanoscience and nanotechnology research at the intersections of chemistry, biology, materials science, physics, and engineering. The journal fosters communication among scientists in these communities, facilitating collaboration, new research opportunities, and advancements through discoveries. ACS Nano covers synthesis, assembly, characterization, theory, and simulation of nanostructures, nanobiotechnology, nanofabrication, methods and tools for nanoscience and nanotechnology, and self- and directed-assembly. Alongside original research articles, it offers thorough reviews, perspectives on cutting-edge research, and discussions envisioning the future of nanoscience and nanotechnology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信