Yoshito Gando, Takeo Yasu, Mari Shimoda, Masao Tukada
{"title":"高效液相色谱-紫外法测定套细胞淋巴瘤患者吡托鲁替尼水平","authors":"Yoshito Gando, Takeo Yasu, Mari Shimoda, Masao Tukada","doi":"10.1002/bmc.70061","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Pirtobrutinib is a Bruton's tyrosine kinase inhibitor used to treat mantle cell lymphoma and chronic lymphocytic leukemia. Pirtobrutinib has a steady-state trough concentration of > 825 ng/mL, corresponding to a 90% inhibitory concentration of Bruton's tyrosine kinase. Therefore, maintaining stable trough concentrations of pirtobrutinib is clinically important; however, no methods of monitoring pirtobrutinib levels have been developed. In this study, our aim was to develop a method to determine pirtobrutinib levels in human plasma and validate it for therapeutic drug monitoring. Pirtobrutinib and ibrutinib (internal standard) were separated on a reversed-phase column using a mobile phase comprising 0.5% KH<sub>2</sub>PO<sub>4</sub> (pH 4.5) and acetonitrile (52:48, v/v) at a flow rate of 1.0 mL/min. Ultraviolet detection was performed at 234 nm. Calibration curves for pirtobrutinib were linear (<i>r</i><sup>2</sup> = 0.9998) in the range of 0.25–10 μg/mL. The intraday and interday validation coefficients were 0.72%–2.86% and 1.29%–3.22%, respectively. This study is the first one to develop and validate a method for quantifying pirtobrutinib in human plasma. These findings may support the widespread application of therapeutic drug monitoring for pirtobrutinib.</p>\n </div>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 5","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-Performance Liquid Chromatography–Ultraviolet Assay for the Determination of Pirtobrutinib Levels in a Patient With Mantle Cell Lymphoma\",\"authors\":\"Yoshito Gando, Takeo Yasu, Mari Shimoda, Masao Tukada\",\"doi\":\"10.1002/bmc.70061\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>Pirtobrutinib is a Bruton's tyrosine kinase inhibitor used to treat mantle cell lymphoma and chronic lymphocytic leukemia. Pirtobrutinib has a steady-state trough concentration of > 825 ng/mL, corresponding to a 90% inhibitory concentration of Bruton's tyrosine kinase. Therefore, maintaining stable trough concentrations of pirtobrutinib is clinically important; however, no methods of monitoring pirtobrutinib levels have been developed. In this study, our aim was to develop a method to determine pirtobrutinib levels in human plasma and validate it for therapeutic drug monitoring. Pirtobrutinib and ibrutinib (internal standard) were separated on a reversed-phase column using a mobile phase comprising 0.5% KH<sub>2</sub>PO<sub>4</sub> (pH 4.5) and acetonitrile (52:48, v/v) at a flow rate of 1.0 mL/min. Ultraviolet detection was performed at 234 nm. Calibration curves for pirtobrutinib were linear (<i>r</i><sup>2</sup> = 0.9998) in the range of 0.25–10 μg/mL. The intraday and interday validation coefficients were 0.72%–2.86% and 1.29%–3.22%, respectively. This study is the first one to develop and validate a method for quantifying pirtobrutinib in human plasma. These findings may support the widespread application of therapeutic drug monitoring for pirtobrutinib.</p>\\n </div>\",\"PeriodicalId\":8861,\"journal\":{\"name\":\"Biomedical Chromatography\",\"volume\":\"39 5\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Chromatography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bmc.70061\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.70061","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
High-Performance Liquid Chromatography–Ultraviolet Assay for the Determination of Pirtobrutinib Levels in a Patient With Mantle Cell Lymphoma
Pirtobrutinib is a Bruton's tyrosine kinase inhibitor used to treat mantle cell lymphoma and chronic lymphocytic leukemia. Pirtobrutinib has a steady-state trough concentration of > 825 ng/mL, corresponding to a 90% inhibitory concentration of Bruton's tyrosine kinase. Therefore, maintaining stable trough concentrations of pirtobrutinib is clinically important; however, no methods of monitoring pirtobrutinib levels have been developed. In this study, our aim was to develop a method to determine pirtobrutinib levels in human plasma and validate it for therapeutic drug monitoring. Pirtobrutinib and ibrutinib (internal standard) were separated on a reversed-phase column using a mobile phase comprising 0.5% KH2PO4 (pH 4.5) and acetonitrile (52:48, v/v) at a flow rate of 1.0 mL/min. Ultraviolet detection was performed at 234 nm. Calibration curves for pirtobrutinib were linear (r2 = 0.9998) in the range of 0.25–10 μg/mL. The intraday and interday validation coefficients were 0.72%–2.86% and 1.29%–3.22%, respectively. This study is the first one to develop and validate a method for quantifying pirtobrutinib in human plasma. These findings may support the widespread application of therapeutic drug monitoring for pirtobrutinib.
期刊介绍:
Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.