利用增强现实技术加强经口内窥镜甲状腺手术中的喉返神经定位:概念验证研究。

IF 1.2 4区 医学 Q3 SURGERY
Moon Young Oh, Yeonjin Choi, Taesoo Jang, Eun Kyung Choe, Hyoun-Joong Kong, Young Jun Chai
{"title":"利用增强现实技术加强经口内窥镜甲状腺手术中的喉返神经定位:概念验证研究。","authors":"Moon Young Oh, Yeonjin Choi, Taesoo Jang, Eun Kyung Choe, Hyoun-Joong Kong, Young Jun Chai","doi":"10.4174/astr.2025.108.3.135","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>During transoral endoscopic thyroidectomy, preserving the recurrent laryngeal nerve (RLN) is a major challenge because visualization of this nerve is often obstructed by the thyroid itself, increasing the risk of serious complications. This study explores the application of an augmented reality (AR) system to facilitate easier identification of the RLN during transoral endoscopic thyroidectomy.</p><p><strong>Methods: </strong>Three patients scheduled for transoral endoscopic thyroidectomy were enrolled in this proof-of-concept study. Preoperative computed tomography scans were used to create an AR model that included the thyroid, trachea, veins, arteries, and RLN. The model was overlaid onto real-time endoscopic camera images during live surgeries. Manual registration of the AR model was performed using a customized controller. The model was aligned with surgical landmarks such as the trachea and common carotid artery. Manual registration accuracy was assessed using the Dice similarity coefficient (DSC) to evaluate the alignment between the real RLN and the RLN of the AR model.</p><p><strong>Results: </strong>The 3 patients included were female (mean age, 33.3 ± 15.7 years), and the mean tumor size was 1.0 ± 0.3 cm. All patients underwent transoral endoscopic thyroidectomy of the right lobe. Final histopathological diagnoses comprised 2 papillary thyroid carcinomas and one follicular adenoma. The manual registration accuracy was 0.60, 0.70, and 0.57 for patients 1, 2, and 3, respectively, with a mean value of 0.6 ± 0.1.</p><p><strong>Conclusion: </strong>The application of an AR system during transoral endoscopic thyroidectomy proved feasible and demonstrated potential for improving the localization of anatomical structures, particularly the RLN, as indicated by a moderate DSC.</p>","PeriodicalId":8071,"journal":{"name":"Annals of Surgical Treatment and Research","volume":"108 3","pages":"135-142"},"PeriodicalIF":1.2000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11896764/pdf/","citationCount":"0","resultStr":"{\"title\":\"Enhancing recurrent laryngeal nerve localization during transoral endoscopic thyroid surgery using augmented reality: a proof-of-concept study.\",\"authors\":\"Moon Young Oh, Yeonjin Choi, Taesoo Jang, Eun Kyung Choe, Hyoun-Joong Kong, Young Jun Chai\",\"doi\":\"10.4174/astr.2025.108.3.135\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>During transoral endoscopic thyroidectomy, preserving the recurrent laryngeal nerve (RLN) is a major challenge because visualization of this nerve is often obstructed by the thyroid itself, increasing the risk of serious complications. This study explores the application of an augmented reality (AR) system to facilitate easier identification of the RLN during transoral endoscopic thyroidectomy.</p><p><strong>Methods: </strong>Three patients scheduled for transoral endoscopic thyroidectomy were enrolled in this proof-of-concept study. Preoperative computed tomography scans were used to create an AR model that included the thyroid, trachea, veins, arteries, and RLN. The model was overlaid onto real-time endoscopic camera images during live surgeries. Manual registration of the AR model was performed using a customized controller. The model was aligned with surgical landmarks such as the trachea and common carotid artery. Manual registration accuracy was assessed using the Dice similarity coefficient (DSC) to evaluate the alignment between the real RLN and the RLN of the AR model.</p><p><strong>Results: </strong>The 3 patients included were female (mean age, 33.3 ± 15.7 years), and the mean tumor size was 1.0 ± 0.3 cm. All patients underwent transoral endoscopic thyroidectomy of the right lobe. Final histopathological diagnoses comprised 2 papillary thyroid carcinomas and one follicular adenoma. The manual registration accuracy was 0.60, 0.70, and 0.57 for patients 1, 2, and 3, respectively, with a mean value of 0.6 ± 0.1.</p><p><strong>Conclusion: </strong>The application of an AR system during transoral endoscopic thyroidectomy proved feasible and demonstrated potential for improving the localization of anatomical structures, particularly the RLN, as indicated by a moderate DSC.</p>\",\"PeriodicalId\":8071,\"journal\":{\"name\":\"Annals of Surgical Treatment and Research\",\"volume\":\"108 3\",\"pages\":\"135-142\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11896764/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Surgical Treatment and Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4174/astr.2025.108.3.135\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Surgical Treatment and Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4174/astr.2025.108.3.135","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enhancing recurrent laryngeal nerve localization during transoral endoscopic thyroid surgery using augmented reality: a proof-of-concept study.

Purpose: During transoral endoscopic thyroidectomy, preserving the recurrent laryngeal nerve (RLN) is a major challenge because visualization of this nerve is often obstructed by the thyroid itself, increasing the risk of serious complications. This study explores the application of an augmented reality (AR) system to facilitate easier identification of the RLN during transoral endoscopic thyroidectomy.

Methods: Three patients scheduled for transoral endoscopic thyroidectomy were enrolled in this proof-of-concept study. Preoperative computed tomography scans were used to create an AR model that included the thyroid, trachea, veins, arteries, and RLN. The model was overlaid onto real-time endoscopic camera images during live surgeries. Manual registration of the AR model was performed using a customized controller. The model was aligned with surgical landmarks such as the trachea and common carotid artery. Manual registration accuracy was assessed using the Dice similarity coefficient (DSC) to evaluate the alignment between the real RLN and the RLN of the AR model.

Results: The 3 patients included were female (mean age, 33.3 ± 15.7 years), and the mean tumor size was 1.0 ± 0.3 cm. All patients underwent transoral endoscopic thyroidectomy of the right lobe. Final histopathological diagnoses comprised 2 papillary thyroid carcinomas and one follicular adenoma. The manual registration accuracy was 0.60, 0.70, and 0.57 for patients 1, 2, and 3, respectively, with a mean value of 0.6 ± 0.1.

Conclusion: The application of an AR system during transoral endoscopic thyroidectomy proved feasible and demonstrated potential for improving the localization of anatomical structures, particularly the RLN, as indicated by a moderate DSC.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
7.10%
发文量
75
期刊介绍: Manuscripts to the Annals of Surgical Treatment and Research (Ann Surg Treat Res) should be written in English according to the instructions for authors. If the details are not described below, the style should follow the Uniform Requirements for Manuscripts Submitted to Biomedical Journals: Writing and Editing for Biomedical Publications available at International Committee of Medical Journal Editors (ICMJE) website (http://www.icmje.org).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信