兰德尔箔与大叶片:在水上短跑赛艇的比较分析。

IF 4.3 2区 医学 Q1 PHYSIOLOGY
Ricardo Cardoso, Manoel Rios, Filipa Cardoso, Segan Bouicher, J Arturo Abraldes, Beatriz B Gomes, João Paulo Vilas-Boas, Ricardo J Fernandes
{"title":"兰德尔箔与大叶片:在水上短跑赛艇的比较分析。","authors":"Ricardo Cardoso, Manoel Rios, Filipa Cardoso, Segan Bouicher, J Arturo Abraldes, Beatriz B Gomes, João Paulo Vilas-Boas, Ricardo J Fernandes","doi":"10.1123/ijspp.2024-0515","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We evaluated the technical and energetical impact of using Randall foils versus simple Big blades during a maximum rowing effort in field conditions.</p><p><strong>Methods: </strong>Fourteen experienced rowers (12 male and 2 female) 26 (9) versus 25 (9) years of age, 179.8 (4.3) versus 175.0 (2.8) cm in height, and 74.2 (4.8) versus 65.5 (6.2) kg of body mass (for males and females, respectively) performed 2 maximal 500-m on-water bouts (1 each using Randall foils and simple Big blades in a randomized order). Performance and physiological variables were continuously measured along the efforts, with the latter being also recorded during the baseline and recovery periods.</p><p><strong>Results: </strong>Rowing time was shorter using Randall foils when compared with simple Big blades (107.59 [5.53] vs 108.96 [5.44] s), while cycle rate (39.73 [2.56] vs 39.71 [2.24] cycle·min-1), peak oxygen uptake (63.47 [9.96] vs 62.68 [9.65] mL·kg-1·min-1), mean oxygen uptake (4.15 [0.77] vs 4.12 [0.78] L·min-1), respiratory frequency (62.44 [9.22] vs 62.17 [11.22] beats·min-1), peak heart rate (178 [11] vs 180 [9] beats·min-1], peak blood lactate concentration (14.26 [3.52] vs 13.76 [4.02] mmol · L-1), and rating of perceived effort (17 [1.43] vs 17 [1]) were similar in both experimental conditions. Furthermore, it was observed that the aerobic pathway represented ∼50% of the total energy spent in the 500-m sprint independently of the blades used.</p><p><strong>Conclusions: </strong>Data suggest that the use of Randall foils enhances rowing performance without compromising rowers' mechanical and metabolic functions.</p>","PeriodicalId":14295,"journal":{"name":"International journal of sports physiology and performance","volume":" ","pages":"678-683"},"PeriodicalIF":4.3000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Randall Foils Versus Big Blades: Comparative Analysis in On-Water Sprint Rowing.\",\"authors\":\"Ricardo Cardoso, Manoel Rios, Filipa Cardoso, Segan Bouicher, J Arturo Abraldes, Beatriz B Gomes, João Paulo Vilas-Boas, Ricardo J Fernandes\",\"doi\":\"10.1123/ijspp.2024-0515\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We evaluated the technical and energetical impact of using Randall foils versus simple Big blades during a maximum rowing effort in field conditions.</p><p><strong>Methods: </strong>Fourteen experienced rowers (12 male and 2 female) 26 (9) versus 25 (9) years of age, 179.8 (4.3) versus 175.0 (2.8) cm in height, and 74.2 (4.8) versus 65.5 (6.2) kg of body mass (for males and females, respectively) performed 2 maximal 500-m on-water bouts (1 each using Randall foils and simple Big blades in a randomized order). Performance and physiological variables were continuously measured along the efforts, with the latter being also recorded during the baseline and recovery periods.</p><p><strong>Results: </strong>Rowing time was shorter using Randall foils when compared with simple Big blades (107.59 [5.53] vs 108.96 [5.44] s), while cycle rate (39.73 [2.56] vs 39.71 [2.24] cycle·min-1), peak oxygen uptake (63.47 [9.96] vs 62.68 [9.65] mL·kg-1·min-1), mean oxygen uptake (4.15 [0.77] vs 4.12 [0.78] L·min-1), respiratory frequency (62.44 [9.22] vs 62.17 [11.22] beats·min-1), peak heart rate (178 [11] vs 180 [9] beats·min-1], peak blood lactate concentration (14.26 [3.52] vs 13.76 [4.02] mmol · L-1), and rating of perceived effort (17 [1.43] vs 17 [1]) were similar in both experimental conditions. Furthermore, it was observed that the aerobic pathway represented ∼50% of the total energy spent in the 500-m sprint independently of the blades used.</p><p><strong>Conclusions: </strong>Data suggest that the use of Randall foils enhances rowing performance without compromising rowers' mechanical and metabolic functions.</p>\",\"PeriodicalId\":14295,\"journal\":{\"name\":\"International journal of sports physiology and performance\",\"volume\":\" \",\"pages\":\"678-683\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2025-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of sports physiology and performance\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1123/ijspp.2024-0515\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/5/1 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q1\",\"JCRName\":\"PHYSIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of sports physiology and performance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1123/ijspp.2024-0515","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/5/1 0:00:00","PubModel":"Print","JCR":"Q1","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:我们评估了技术和能量的影响,使用兰德尔箔与简单的大叶片在最大的划船努力在现场条件下。方法:14名经验丰富的赛艇运动员(12名男性和2名女性),年龄分别为26(9)和25(9)岁,身高分别为179.8(4.3)和175.0 (2.8)cm,体重分别为74.2(4.8)和65.5 (6.2)kg(男性和女性),进行了2次最大500米水上比赛(随机顺序使用兰德尔花剑和简单大桨各1次)。在训练过程中不断测量表现和生理变量,并在基线和恢复期记录后者。结果:与简单的大桨相比,Randall桨叶划船时间(107.59 [5.53]vs 108.96 [5.44] s)更短,而周期率(39.73 [2.56]vs 39.71 [2.24] cycles·min-1)、峰值摄氧量(63.47 [9.96]vs 62.68 [9.65] mL·kg-1·min-1)、平均摄氧量(4.15 [0.77]vs 4.12 [0.78] L·min-1)、呼吸频率(62.44 [9.22]vs 62.17[11.22]次·min-1)、峰值心率(178 [3.52]vs 13.76 [4.02] mmol·L-1)、在两种实验条件下,感知努力评分(17 [1.43]vs 17[1])相似。此外,还观察到有氧途径在500米冲刺中消耗的总能量中约占50%,与使用的叶片无关。结论:数据表明,使用兰德尔箔提高赛艇性能,而不损害赛艇运动员的机械和代谢功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Randall Foils Versus Big Blades: Comparative Analysis in On-Water Sprint Rowing.

Purpose: We evaluated the technical and energetical impact of using Randall foils versus simple Big blades during a maximum rowing effort in field conditions.

Methods: Fourteen experienced rowers (12 male and 2 female) 26 (9) versus 25 (9) years of age, 179.8 (4.3) versus 175.0 (2.8) cm in height, and 74.2 (4.8) versus 65.5 (6.2) kg of body mass (for males and females, respectively) performed 2 maximal 500-m on-water bouts (1 each using Randall foils and simple Big blades in a randomized order). Performance and physiological variables were continuously measured along the efforts, with the latter being also recorded during the baseline and recovery periods.

Results: Rowing time was shorter using Randall foils when compared with simple Big blades (107.59 [5.53] vs 108.96 [5.44] s), while cycle rate (39.73 [2.56] vs 39.71 [2.24] cycle·min-1), peak oxygen uptake (63.47 [9.96] vs 62.68 [9.65] mL·kg-1·min-1), mean oxygen uptake (4.15 [0.77] vs 4.12 [0.78] L·min-1), respiratory frequency (62.44 [9.22] vs 62.17 [11.22] beats·min-1), peak heart rate (178 [11] vs 180 [9] beats·min-1], peak blood lactate concentration (14.26 [3.52] vs 13.76 [4.02] mmol · L-1), and rating of perceived effort (17 [1.43] vs 17 [1]) were similar in both experimental conditions. Furthermore, it was observed that the aerobic pathway represented ∼50% of the total energy spent in the 500-m sprint independently of the blades used.

Conclusions: Data suggest that the use of Randall foils enhances rowing performance without compromising rowers' mechanical and metabolic functions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.80
自引率
12.10%
发文量
199
审稿时长
6-12 weeks
期刊介绍: The International Journal of Sports Physiology and Performance (IJSPP) focuses on sport physiology and performance and is dedicated to advancing the knowledge of sport and exercise physiologists, sport-performance researchers, and other sport scientists. The journal publishes authoritative peer-reviewed research in sport physiology and related disciplines, with an emphasis on work having direct practical applications in enhancing sport performance in sport physiology and related disciplines. IJSPP publishes 10 issues per year: January, February, March, April, May, July, August, September, October, and November.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信