高、低半透明单片氧化锆冠在重复烧成循环中的垂直边缘差异比较。

Q1 Dentistry
Mehrzad Moazzam, Amirhossein Fathi, Mahsa Ghorbani, Ramin Mosharraf
{"title":"高、低半透明单片氧化锆冠在重复烧成循环中的垂直边缘差异比较。","authors":"Mehrzad Moazzam, Amirhossein Fathi, Mahsa Ghorbani, Ramin Mosharraf","doi":"10.1055/s-0044-1801303","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong> Increase in vertical marginal discrepancy (VMD) during repeated firing cycles and its clinical outcomes is a major concern for high and low translucent monolithic zirconia crowns. The purpose of this in vitro study was to evaluate and compare VMD in high and low translucent monolithic zirconia crowns in repeated firing cycles.</p><p><strong>Material and methods: </strong> To perform this study, 10 monolithic zirconia crowns made by computer-aided design and computer-aided manufacturing method were used in two groups of five with high and low translucency, which were designed on Zimmer tissue-level implant abutment. The crowns in each group were randomly numbered from 1 to 5 and each underwent 1, 3, and 5 firing cycles. After completing each mentioned cycle, the VMD was measured at eight predetermined points on abutment by optical microscope and their average was recorded for each sample. Data analysis was done by SPSS 22 software through repeated-measure analysis of variance, paired <i>t</i>-test, and <i>t</i>-test with a 5% significance threshold.</p><p><strong>Results: </strong> A total of 240 measurements were made for the VMD, which, due to the presence of five samples in each translucency group and eight examined points in each sample, was finally summed up to six averages for each translucency group in the mentioned three stages of firing cycles. The averages for the low-translucency group after 1, 3, and 5 firing cycles were 76.86, 85.02, and 90.55 μm, respectively, and for the high-translucency group after 1, 3, and 5 firing cycles were 80.38, 87.33, and 97.78 μm, respectively. The average VMD of the samples regardless of the translucency level after 1, 3 and 5 firing cycles was calculated as 78.62, 86.18, and 94.16 μm, respectively.</p><p><strong>Conclusion: </strong> This study found that VMD increased with repeated firing cycles, with no significant difference between high- and low-translucency zirconia crowns. Repeated firings significantly raised VMD, but all values remained within clinically acceptable limits, supporting the suitability of both translucency types for clinical use.</p>","PeriodicalId":12028,"journal":{"name":"European Journal of Dentistry","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Vertical Marginal Discrepancy in High and Low Translucent Monolithic Zirconia Crowns in Repeated Firing Cycles.\",\"authors\":\"Mehrzad Moazzam, Amirhossein Fathi, Mahsa Ghorbani, Ramin Mosharraf\",\"doi\":\"10.1055/s-0044-1801303\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong> Increase in vertical marginal discrepancy (VMD) during repeated firing cycles and its clinical outcomes is a major concern for high and low translucent monolithic zirconia crowns. The purpose of this in vitro study was to evaluate and compare VMD in high and low translucent monolithic zirconia crowns in repeated firing cycles.</p><p><strong>Material and methods: </strong> To perform this study, 10 monolithic zirconia crowns made by computer-aided design and computer-aided manufacturing method were used in two groups of five with high and low translucency, which were designed on Zimmer tissue-level implant abutment. The crowns in each group were randomly numbered from 1 to 5 and each underwent 1, 3, and 5 firing cycles. After completing each mentioned cycle, the VMD was measured at eight predetermined points on abutment by optical microscope and their average was recorded for each sample. Data analysis was done by SPSS 22 software through repeated-measure analysis of variance, paired <i>t</i>-test, and <i>t</i>-test with a 5% significance threshold.</p><p><strong>Results: </strong> A total of 240 measurements were made for the VMD, which, due to the presence of five samples in each translucency group and eight examined points in each sample, was finally summed up to six averages for each translucency group in the mentioned three stages of firing cycles. The averages for the low-translucency group after 1, 3, and 5 firing cycles were 76.86, 85.02, and 90.55 μm, respectively, and for the high-translucency group after 1, 3, and 5 firing cycles were 80.38, 87.33, and 97.78 μm, respectively. The average VMD of the samples regardless of the translucency level after 1, 3 and 5 firing cycles was calculated as 78.62, 86.18, and 94.16 μm, respectively.</p><p><strong>Conclusion: </strong> This study found that VMD increased with repeated firing cycles, with no significant difference between high- and low-translucency zirconia crowns. Repeated firings significantly raised VMD, but all values remained within clinically acceptable limits, supporting the suitability of both translucency types for clinical use.</p>\",\"PeriodicalId\":12028,\"journal\":{\"name\":\"European Journal of Dentistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0044-1801303\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1801303","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:高、低半透明单片氧化锆冠在重复放电周期中垂直边缘差(VMD)的增加及其临床结果值得关注。本体外研究的目的是评估和比较高、低半透明单片氧化锆冠在重复放电周期下的VMD。材料与方法:本研究采用计算机辅助设计和计算机辅助制造方法制作的整体氧化锆冠10个,分为高通透性和低通透性两组,每组5个,设计在Zimmer组织水平种植基牙上。各组冠随机编号为1 ~ 5,分别进行1、3、5个放电周期。在完成上述每个周期后,在基台上预定的8个点用光学显微镜测量VMD,并记录每个样品的平均值。数据分析采用SPSS 22软件,采用重复测量方差分析、配对t检验和5%显著性阈值t检验。结果:共对VMD进行了240次测量,由于每个半透明组中有5个样本,每个样本中有8个检查点,最终总结为上述三个发射周期阶段中每个半透明组的6个平均值。低透性组在1、3、5个放电周期后的平均孔径分别为76.86、85.02、90.55 μm;高透性组在1、3、5个放电周期后的平均孔径分别为80.38、87.33、97.78 μm。经过1、3和5次循环后,样品的平均VMD分别为78.62、86.18和94.16 μm。结论:本研究发现,随着重复放电周期的增加,VMD增加,高透明度和低透明度氧化锆冠之间无显著差异。反复发射可显著提高VMD,但所有数值仍在临床可接受范围内,支持两种半透明类型的临床应用适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Vertical Marginal Discrepancy in High and Low Translucent Monolithic Zirconia Crowns in Repeated Firing Cycles.

Objective:  Increase in vertical marginal discrepancy (VMD) during repeated firing cycles and its clinical outcomes is a major concern for high and low translucent monolithic zirconia crowns. The purpose of this in vitro study was to evaluate and compare VMD in high and low translucent monolithic zirconia crowns in repeated firing cycles.

Material and methods:  To perform this study, 10 monolithic zirconia crowns made by computer-aided design and computer-aided manufacturing method were used in two groups of five with high and low translucency, which were designed on Zimmer tissue-level implant abutment. The crowns in each group were randomly numbered from 1 to 5 and each underwent 1, 3, and 5 firing cycles. After completing each mentioned cycle, the VMD was measured at eight predetermined points on abutment by optical microscope and their average was recorded for each sample. Data analysis was done by SPSS 22 software through repeated-measure analysis of variance, paired t-test, and t-test with a 5% significance threshold.

Results:  A total of 240 measurements were made for the VMD, which, due to the presence of five samples in each translucency group and eight examined points in each sample, was finally summed up to six averages for each translucency group in the mentioned three stages of firing cycles. The averages for the low-translucency group after 1, 3, and 5 firing cycles were 76.86, 85.02, and 90.55 μm, respectively, and for the high-translucency group after 1, 3, and 5 firing cycles were 80.38, 87.33, and 97.78 μm, respectively. The average VMD of the samples regardless of the translucency level after 1, 3 and 5 firing cycles was calculated as 78.62, 86.18, and 94.16 μm, respectively.

Conclusion:  This study found that VMD increased with repeated firing cycles, with no significant difference between high- and low-translucency zirconia crowns. Repeated firings significantly raised VMD, but all values remained within clinically acceptable limits, supporting the suitability of both translucency types for clinical use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of Dentistry
European Journal of Dentistry Dentistry-Dentistry (all)
CiteScore
5.10
自引率
0.00%
发文量
161
期刊介绍: The European Journal of Dentistry is the official journal of the Dental Investigations Society, based in Turkey. It is a double-blinded peer-reviewed, Open Access, multi-disciplinary international journal addressing various aspects of dentistry. The journal''s board consists of eminent investigators in dentistry from across the globe and presents an ideal international composition. The journal encourages its authors to submit original investigations, reviews, and reports addressing various divisions of dentistry including oral pathology, prosthodontics, endodontics, orthodontics etc. It is available both online and in print.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信