通过 4D 流式心脏 MRI 测量动能以评估室内血流动力学:系统性综述。

IF 3.3 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Jing Zhu, Xiaolin Mu, Wenjia Wang, Yang Song
{"title":"通过 4D 流式心脏 MRI 测量动能以评估室内血流动力学:系统性综述。","authors":"Jing Zhu, Xiaolin Mu, Wenjia Wang, Yang Song","doi":"10.1002/jmri.29759","DOIUrl":null,"url":null,"abstract":"<p><p>Four-dimensional flow cardiovascular magnetic resonance (4D Flow cardiac MRI) is an advanced non-invasive imaging technology, and its derived kinetic energy (KE) blood flow parameters have been confirmed as a potential biomarkers for assessing ventricular hemodynamics. This review synthesizes details on the methodology, clinical significance, and current status of studies focused on quantifying KE parameters of the ventricle using 4D Flow cardiac MRI, providing an objective foundation for further exploration of the value of KE in cardiac diseases.</p><p><strong>Study type: </strong>retrospective.</p><p><strong>Subjects: </strong>This review includes studies that utilized 4D Flow cardiac MRI in human subjects, focusing on the changes in KE parameters. Field Strength: 1.5T or 3T.</p><p><strong>Assessment: </strong>A systematic review was conducted to assess the literature on the intracardiac clinical applications of 4D Flow cardiac MRI. In September 2024, searches were performed in PubMed, Web of Science, SCIENCEDIRECT, and Springer Link databases using the keywords \"4D Flow cardiac MRI,\" \"ventricular kinetic energy,\" and \"intraventricular hemodynamics,\" covering a period of 10 years. The inclusion criteria for the literature were: (1) clinical trials with human subjects; (2) studies that addressed the value of 4D Flow cardiovascular magnetic resonance and its derived blood flow KE parameters in quantifying ventricular blood flow. The exclusion criteria were: (1) animal experimental studies; (2) non-English core journal articles. Out of the 195 articles screened, 62 studies met the criteria for the systematic review. The included literature comprised 26 (41.9%) studies on 4D Flow cardiac MRI technology and blood flow parameter research, and 36 (58.1%) clinical application studies. KE measurement using 4D Flow cardiac MRI is a promising tool for evaluating ventricular hemodynamics. It provides clinicians with deeper insights into the physiological and pathological dynamics of ventricular blood flow, from healthy states to disease.</p>","PeriodicalId":16140,"journal":{"name":"Journal of Magnetic Resonance Imaging","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Kinetic Energy Measured by 4D Flow Cardiac MRI in Evaluating Intraventricular Hemodynamics: A Systematic Review.\",\"authors\":\"Jing Zhu, Xiaolin Mu, Wenjia Wang, Yang Song\",\"doi\":\"10.1002/jmri.29759\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Four-dimensional flow cardiovascular magnetic resonance (4D Flow cardiac MRI) is an advanced non-invasive imaging technology, and its derived kinetic energy (KE) blood flow parameters have been confirmed as a potential biomarkers for assessing ventricular hemodynamics. This review synthesizes details on the methodology, clinical significance, and current status of studies focused on quantifying KE parameters of the ventricle using 4D Flow cardiac MRI, providing an objective foundation for further exploration of the value of KE in cardiac diseases.</p><p><strong>Study type: </strong>retrospective.</p><p><strong>Subjects: </strong>This review includes studies that utilized 4D Flow cardiac MRI in human subjects, focusing on the changes in KE parameters. Field Strength: 1.5T or 3T.</p><p><strong>Assessment: </strong>A systematic review was conducted to assess the literature on the intracardiac clinical applications of 4D Flow cardiac MRI. In September 2024, searches were performed in PubMed, Web of Science, SCIENCEDIRECT, and Springer Link databases using the keywords \\\"4D Flow cardiac MRI,\\\" \\\"ventricular kinetic energy,\\\" and \\\"intraventricular hemodynamics,\\\" covering a period of 10 years. The inclusion criteria for the literature were: (1) clinical trials with human subjects; (2) studies that addressed the value of 4D Flow cardiovascular magnetic resonance and its derived blood flow KE parameters in quantifying ventricular blood flow. The exclusion criteria were: (1) animal experimental studies; (2) non-English core journal articles. Out of the 195 articles screened, 62 studies met the criteria for the systematic review. The included literature comprised 26 (41.9%) studies on 4D Flow cardiac MRI technology and blood flow parameter research, and 36 (58.1%) clinical application studies. KE measurement using 4D Flow cardiac MRI is a promising tool for evaluating ventricular hemodynamics. It provides clinicians with deeper insights into the physiological and pathological dynamics of ventricular blood flow, from healthy states to disease.</p>\",\"PeriodicalId\":16140,\"journal\":{\"name\":\"Journal of Magnetic Resonance Imaging\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-03-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jmri.29759\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jmri.29759","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Kinetic Energy Measured by 4D Flow Cardiac MRI in Evaluating Intraventricular Hemodynamics: A Systematic Review.

Four-dimensional flow cardiovascular magnetic resonance (4D Flow cardiac MRI) is an advanced non-invasive imaging technology, and its derived kinetic energy (KE) blood flow parameters have been confirmed as a potential biomarkers for assessing ventricular hemodynamics. This review synthesizes details on the methodology, clinical significance, and current status of studies focused on quantifying KE parameters of the ventricle using 4D Flow cardiac MRI, providing an objective foundation for further exploration of the value of KE in cardiac diseases.

Study type: retrospective.

Subjects: This review includes studies that utilized 4D Flow cardiac MRI in human subjects, focusing on the changes in KE parameters. Field Strength: 1.5T or 3T.

Assessment: A systematic review was conducted to assess the literature on the intracardiac clinical applications of 4D Flow cardiac MRI. In September 2024, searches were performed in PubMed, Web of Science, SCIENCEDIRECT, and Springer Link databases using the keywords "4D Flow cardiac MRI," "ventricular kinetic energy," and "intraventricular hemodynamics," covering a period of 10 years. The inclusion criteria for the literature were: (1) clinical trials with human subjects; (2) studies that addressed the value of 4D Flow cardiovascular magnetic resonance and its derived blood flow KE parameters in quantifying ventricular blood flow. The exclusion criteria were: (1) animal experimental studies; (2) non-English core journal articles. Out of the 195 articles screened, 62 studies met the criteria for the systematic review. The included literature comprised 26 (41.9%) studies on 4D Flow cardiac MRI technology and blood flow parameter research, and 36 (58.1%) clinical application studies. KE measurement using 4D Flow cardiac MRI is a promising tool for evaluating ventricular hemodynamics. It provides clinicians with deeper insights into the physiological and pathological dynamics of ventricular blood flow, from healthy states to disease.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.70
自引率
6.80%
发文量
494
审稿时长
2 months
期刊介绍: The Journal of Magnetic Resonance Imaging (JMRI) is an international journal devoted to the timely publication of basic and clinical research, educational and review articles, and other information related to the diagnostic applications of magnetic resonance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信