探索人鼻抗体测定的标准化。

IF 7.5 2区 医学 Q1 IMMUNOLOGY
Emerging Microbes & Infections Pub Date : 2025-12-01 Epub Date: 2025-03-17 DOI:10.1080/22221751.2025.2475822
Xuanxuan Zhang, Yulong Fu, Si Chen, Guanxing Liu, Ying Wang, Qian He, Qian Wang, Na Li, Zhongfang Wang, Ling Chen, Junzhi Wang, Zhenglun Liang, Miao Xu, Qunying Mao
{"title":"探索人鼻抗体测定的标准化。","authors":"Xuanxuan Zhang, Yulong Fu, Si Chen, Guanxing Liu, Ying Wang, Qian He, Qian Wang, Na Li, Zhongfang Wang, Ling Chen, Junzhi Wang, Zhenglun Liang, Miao Xu, Qunying Mao","doi":"10.1080/22221751.2025.2475822","DOIUrl":null,"url":null,"abstract":"<p><p>Mucosal immunity is crucial for preventing the infection and transmission of respiratory viruses. Nasal antibody is inversely correlated with a lower risk of infection with respiratory viruses. However, the current reference standard for nasal antibody assessment is serum-based, mainly consisting of monomeric IgG and IgA. The applicability of serum-derived standards for assessing nasal antibodies, consisting mostly of dimeric or polymeric secretory IgA (sIgA), remains unvalidated. Herein, we first proved that the sera-derived standard was not applicable for assessing nasal antibodies. Using a non-homologous standard as a calibrator introduced systematic error up to 10 times, which did not benefit the understanding of mucosal antibody response. Therefore, we attempted to develop two candidate standards (CS1, CS2) using nasal mucosal lining fluids (NMLFs) collected from SARS-CoV-2 Omicron convalescents or intranasal vaccine recipients, and CS3 using a sIgA monoclonal antibody. CS2 exhibited broad-spectrum binding activity against 12 SARS-CoV-2 strains, including all tested Omicron subvariants. A collaborative study conducted by seven laboratories demonstrated that CS2 improved the harmonization of inter-laboratory variability (pre-standardization geometric coefficients of variance, 14-314%; post-standardization, 3-35%). Using CS2 ensured an accurate assessment of nasal antibodies. Thus, CS2 was established as a national standard for evaluating nasal SARS-CoV-2-specific antibodies (Lot: 300052-202401, 1000 U/mL). Our work provides a benchmark for evaluating mucosal vaccines for SARS-CoV-2 and inspires new avenues for developing new reference standards for other mucosal vaccines.</p>","PeriodicalId":11602,"journal":{"name":"Emerging Microbes & Infections","volume":" ","pages":"2475822"},"PeriodicalIF":7.5000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11915745/pdf/","citationCount":"0","resultStr":"{\"title\":\"Exploring the standardization of human nasal antibody measurements.\",\"authors\":\"Xuanxuan Zhang, Yulong Fu, Si Chen, Guanxing Liu, Ying Wang, Qian He, Qian Wang, Na Li, Zhongfang Wang, Ling Chen, Junzhi Wang, Zhenglun Liang, Miao Xu, Qunying Mao\",\"doi\":\"10.1080/22221751.2025.2475822\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Mucosal immunity is crucial for preventing the infection and transmission of respiratory viruses. Nasal antibody is inversely correlated with a lower risk of infection with respiratory viruses. However, the current reference standard for nasal antibody assessment is serum-based, mainly consisting of monomeric IgG and IgA. The applicability of serum-derived standards for assessing nasal antibodies, consisting mostly of dimeric or polymeric secretory IgA (sIgA), remains unvalidated. Herein, we first proved that the sera-derived standard was not applicable for assessing nasal antibodies. Using a non-homologous standard as a calibrator introduced systematic error up to 10 times, which did not benefit the understanding of mucosal antibody response. Therefore, we attempted to develop two candidate standards (CS1, CS2) using nasal mucosal lining fluids (NMLFs) collected from SARS-CoV-2 Omicron convalescents or intranasal vaccine recipients, and CS3 using a sIgA monoclonal antibody. CS2 exhibited broad-spectrum binding activity against 12 SARS-CoV-2 strains, including all tested Omicron subvariants. A collaborative study conducted by seven laboratories demonstrated that CS2 improved the harmonization of inter-laboratory variability (pre-standardization geometric coefficients of variance, 14-314%; post-standardization, 3-35%). Using CS2 ensured an accurate assessment of nasal antibodies. Thus, CS2 was established as a national standard for evaluating nasal SARS-CoV-2-specific antibodies (Lot: 300052-202401, 1000 U/mL). Our work provides a benchmark for evaluating mucosal vaccines for SARS-CoV-2 and inspires new avenues for developing new reference standards for other mucosal vaccines.</p>\",\"PeriodicalId\":11602,\"journal\":{\"name\":\"Emerging Microbes & Infections\",\"volume\":\" \",\"pages\":\"2475822\"},\"PeriodicalIF\":7.5000,\"publicationDate\":\"2025-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11915745/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Emerging Microbes & Infections\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/22221751.2025.2475822\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"IMMUNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Emerging Microbes & Infections","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/22221751.2025.2475822","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

黏膜免疫对于预防呼吸道病毒的感染和传播至关重要。鼻腔抗体与较低的呼吸道病毒感染风险呈负相关。然而,目前鼻腔抗体评估的参考标准是基于血清的,主要由单体IgG和IgA组成。用于评估鼻腔抗体(主要由二聚体或聚合分泌IgA (sIgA)组成)的血清衍生标准的适用性仍未得到验证。在此,我们首先证明了血清衍生标准不适用于评估鼻腔抗体。使用非同源标准品作为校准器会引入高达10倍的系统误差,这不利于对粘膜抗体反应的理解。因此,我们试图建立两种候选标准(CS1、CS2),使用从SARS-CoV-2 Omicron康复者或鼻内疫苗接种者收集的鼻黏膜衬里液(nmlf), CS3使用sIgA单克隆抗体。CS2对12株SARS-CoV-2具有广谱结合活性,包括所有测试的Omicron亚变体。由7个实验室进行的一项合作研究表明,CS2提高了实验室间变异的协调性(标准化前的几何变异系数为14-314%;post-standardization 3 - 35%)。使用CS2可确保准确评估鼻腔抗体。因此,建立CS2作为评价鼻腔sars - cov -2特异性抗体的国家标准品(批号:300052-202401,1000 U/mL)。我们的工作为SARS-CoV-2粘膜疫苗的评价提供了基准,并为其他粘膜疫苗制定新的参考标准提供了新的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Exploring the standardization of human nasal antibody measurements.

Exploring the standardization of human nasal antibody measurements.

Exploring the standardization of human nasal antibody measurements.

Exploring the standardization of human nasal antibody measurements.

Mucosal immunity is crucial for preventing the infection and transmission of respiratory viruses. Nasal antibody is inversely correlated with a lower risk of infection with respiratory viruses. However, the current reference standard for nasal antibody assessment is serum-based, mainly consisting of monomeric IgG and IgA. The applicability of serum-derived standards for assessing nasal antibodies, consisting mostly of dimeric or polymeric secretory IgA (sIgA), remains unvalidated. Herein, we first proved that the sera-derived standard was not applicable for assessing nasal antibodies. Using a non-homologous standard as a calibrator introduced systematic error up to 10 times, which did not benefit the understanding of mucosal antibody response. Therefore, we attempted to develop two candidate standards (CS1, CS2) using nasal mucosal lining fluids (NMLFs) collected from SARS-CoV-2 Omicron convalescents or intranasal vaccine recipients, and CS3 using a sIgA monoclonal antibody. CS2 exhibited broad-spectrum binding activity against 12 SARS-CoV-2 strains, including all tested Omicron subvariants. A collaborative study conducted by seven laboratories demonstrated that CS2 improved the harmonization of inter-laboratory variability (pre-standardization geometric coefficients of variance, 14-314%; post-standardization, 3-35%). Using CS2 ensured an accurate assessment of nasal antibodies. Thus, CS2 was established as a national standard for evaluating nasal SARS-CoV-2-specific antibodies (Lot: 300052-202401, 1000 U/mL). Our work provides a benchmark for evaluating mucosal vaccines for SARS-CoV-2 and inspires new avenues for developing new reference standards for other mucosal vaccines.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Emerging Microbes & Infections
Emerging Microbes & Infections IMMUNOLOGY-MICROBIOLOGY
CiteScore
26.20
自引率
2.30%
发文量
276
审稿时长
20 weeks
期刊介绍: Emerging Microbes & Infections is a peer-reviewed, open-access journal dedicated to publishing research at the intersection of emerging immunology and microbiology viruses. The journal's mission is to share information on microbes and infections, particularly those gaining significance in both biological and clinical realms due to increased pathogenic frequency. Emerging Microbes & Infections is committed to bridging the scientific gap between developed and developing countries. This journal addresses topics of critical biological and clinical importance, including but not limited to: - Epidemic surveillance - Clinical manifestations - Diagnosis and management - Cellular and molecular pathogenesis - Innate and acquired immune responses between emerging microbes and their hosts - Drug discovery - Vaccine development research Emerging Microbes & Infections invites submissions of original research articles, review articles, letters, and commentaries, fostering a platform for the dissemination of impactful research in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信