左心室辅助装置植入后主动脉根部和瓣膜形态与主动脉瓣返流的关系。

IF 2.2 3区 医学 Q3 ENGINEERING, BIOMEDICAL
Takashi Murakami, Yusuke Misumi, Daisuke Yoshioka, Takuji Kawamura, Ai Kawamura, Shin Yajima, Shunsuke Saito, Takashi Yamauchi, Shigeru Miyagawa
{"title":"左心室辅助装置植入后主动脉根部和瓣膜形态与主动脉瓣返流的关系。","authors":"Takashi Murakami, Yusuke Misumi, Daisuke Yoshioka, Takuji Kawamura, Ai Kawamura, Shin Yajima, Shunsuke Saito, Takashi Yamauchi, Shigeru Miyagawa","doi":"10.1111/aor.14987","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The development of aortic valve regurgitation (AR) negatively affects the survival of patients with continuous-flow left ventricular assist device (LVAD) support. Although several risk factors have been identified, little is known about the effect of preoperative aortic root and valve morphology on the development of de novo AR after LVAD implantation.</p><p><strong>Methods: </strong>Between April 2018 and September 2023, 87 patients underwent durable LVAD implantation at our department. Of these, the 15 eligible patients who underwent preoperative electrocardiography-synchronized cardiac contrast-enhanced computed tomography were included in this study. Baseline aortic root and valve morphology and its relationship with the postoperative development of AR were retrospectively reviewed.</p><p><strong>Results: </strong>The mean duration of LVAD support was 1208 ± 618 days. At 60 months postsurgery, 10 patients had mild or greater AR (Group I) and the others did not (Group N). The measurement of baseline aortic root morphology showed that the ratio of virtual basal ring diameter to geometric height (VBD/GH) was significantly larger for Group I (1.70 ± 0.024 vs. 1.48 ± 0.034; p = 0.0001).</p><p><strong>Conclusions: </strong>A large preoperative VBD/GH is a significant risk factor for de novo AR. This finding may assist in determining the surgical indications for concomitant aortic valve procedures with durable LVAD implantation.</p>","PeriodicalId":8450,"journal":{"name":"Artificial organs","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Association of Aortic Root and Valve Morphology With De Novo Aortic Valve Regurgitation After Implantation of Left Ventricular Assist Device.\",\"authors\":\"Takashi Murakami, Yusuke Misumi, Daisuke Yoshioka, Takuji Kawamura, Ai Kawamura, Shin Yajima, Shunsuke Saito, Takashi Yamauchi, Shigeru Miyagawa\",\"doi\":\"10.1111/aor.14987\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The development of aortic valve regurgitation (AR) negatively affects the survival of patients with continuous-flow left ventricular assist device (LVAD) support. Although several risk factors have been identified, little is known about the effect of preoperative aortic root and valve morphology on the development of de novo AR after LVAD implantation.</p><p><strong>Methods: </strong>Between April 2018 and September 2023, 87 patients underwent durable LVAD implantation at our department. Of these, the 15 eligible patients who underwent preoperative electrocardiography-synchronized cardiac contrast-enhanced computed tomography were included in this study. Baseline aortic root and valve morphology and its relationship with the postoperative development of AR were retrospectively reviewed.</p><p><strong>Results: </strong>The mean duration of LVAD support was 1208 ± 618 days. At 60 months postsurgery, 10 patients had mild or greater AR (Group I) and the others did not (Group N). The measurement of baseline aortic root morphology showed that the ratio of virtual basal ring diameter to geometric height (VBD/GH) was significantly larger for Group I (1.70 ± 0.024 vs. 1.48 ± 0.034; p = 0.0001).</p><p><strong>Conclusions: </strong>A large preoperative VBD/GH is a significant risk factor for de novo AR. This finding may assist in determining the surgical indications for concomitant aortic valve procedures with durable LVAD implantation.</p>\",\"PeriodicalId\":8450,\"journal\":{\"name\":\"Artificial organs\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-03-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Artificial organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/aor.14987\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/aor.14987","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:主动脉瓣返流(AR)的发生对持续流左心室辅助装置(LVAD)支持患者的生存产生负面影响。虽然已经确定了几个危险因素,但对于术前主动脉根部和瓣膜形态对LVAD植入后新生AR发展的影响知之甚少。方法:2018年4月至2023年9月,我科87例患者行持久LVAD植入术。其中,15名接受术前心电图同步心脏对比增强计算机断层扫描的符合条件的患者被纳入本研究。回顾性回顾基线主动脉根和瓣膜形态及其与AR术后发展的关系。结果:LVAD支持时间平均为1208±618天。术后60个月,10例患者出现轻度或较大程度的AR (I组),其余患者无AR (N组)。基线主动脉根部形态学测量显示,I组的虚拟基环直径与几何高度之比(VBD/GH)明显更大(1.70±0.024∶1.48±0.034;p = 0.0001)。结论:术前较大的VBD/GH是新发AR的重要危险因素。这一发现可能有助于确定伴随主动脉瓣手术和持久LVAD植入的手术指征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Association of Aortic Root and Valve Morphology With De Novo Aortic Valve Regurgitation After Implantation of Left Ventricular Assist Device.

Background: The development of aortic valve regurgitation (AR) negatively affects the survival of patients with continuous-flow left ventricular assist device (LVAD) support. Although several risk factors have been identified, little is known about the effect of preoperative aortic root and valve morphology on the development of de novo AR after LVAD implantation.

Methods: Between April 2018 and September 2023, 87 patients underwent durable LVAD implantation at our department. Of these, the 15 eligible patients who underwent preoperative electrocardiography-synchronized cardiac contrast-enhanced computed tomography were included in this study. Baseline aortic root and valve morphology and its relationship with the postoperative development of AR were retrospectively reviewed.

Results: The mean duration of LVAD support was 1208 ± 618 days. At 60 months postsurgery, 10 patients had mild or greater AR (Group I) and the others did not (Group N). The measurement of baseline aortic root morphology showed that the ratio of virtual basal ring diameter to geometric height (VBD/GH) was significantly larger for Group I (1.70 ± 0.024 vs. 1.48 ± 0.034; p = 0.0001).

Conclusions: A large preoperative VBD/GH is a significant risk factor for de novo AR. This finding may assist in determining the surgical indications for concomitant aortic valve procedures with durable LVAD implantation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Artificial organs
Artificial organs 工程技术-工程:生物医学
CiteScore
4.30
自引率
12.50%
发文量
303
审稿时长
4-8 weeks
期刊介绍: Artificial Organs is the official peer reviewed journal of The International Federation for Artificial Organs (Members of the Federation are: The American Society for Artificial Internal Organs, The European Society for Artificial Organs, and The Japanese Society for Artificial Organs), The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, The International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation. Artificial Organs publishes original research articles dealing with developments in artificial organs applications and treatment modalities and their clinical applications worldwide. Membership in the Societies listed above is not a prerequisite for publication. Articles are published without charge to the author except for color figures and excess page charges as noted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信