{"title":"家用超声波水表经多次试验后的性能","authors":"I. Albaina,&nbsp;G.A. Esteban,&nbsp;I. Bidaguren,&nbsp;U. Izquierdo","doi":"10.1016/j.flowmeasinst.2025.102884","DOIUrl":null,"url":null,"abstract":"<div><div>Smart water meters play a crucial role in promoting sustainable urban development, optimizing water management, utility efficiency, and reducing environmental impact. Limited knowledge exists regarding their long-term performance across diverse conditions. This study assessed modern ultrasonic water meters in households, testing six pairs from five brands. Evaluations involved varying water flow rates, simulating starts and stops, abrupt supply changes, and durability assessments. Generally, the meters performed accurately, avoiding consistent over- or undercounting. However, performance varied across brands and models due to technological disparities. Integrated battery-equipped meters met accuracy standards, yet exhibited discrepancies in more demanding testing conditions.</div></div>","PeriodicalId":50440,"journal":{"name":"Flow Measurement and Instrumentation","volume":"104 ","pages":"Article 102884"},"PeriodicalIF":2.3000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Behavior of domestic ultrasonic water meters subjected to multiple tests\",\"authors\":\"I. Albaina,&nbsp;G.A. Esteban,&nbsp;I. Bidaguren,&nbsp;U. Izquierdo\",\"doi\":\"10.1016/j.flowmeasinst.2025.102884\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Smart water meters play a crucial role in promoting sustainable urban development, optimizing water management, utility efficiency, and reducing environmental impact. Limited knowledge exists regarding their long-term performance across diverse conditions. This study assessed modern ultrasonic water meters in households, testing six pairs from five brands. Evaluations involved varying water flow rates, simulating starts and stops, abrupt supply changes, and durability assessments. Generally, the meters performed accurately, avoiding consistent over- or undercounting. However, performance varied across brands and models due to technological disparities. Integrated battery-equipped meters met accuracy standards, yet exhibited discrepancies in more demanding testing conditions.</div></div>\",\"PeriodicalId\":50440,\"journal\":{\"name\":\"Flow Measurement and Instrumentation\",\"volume\":\"104 \",\"pages\":\"Article 102884\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Flow Measurement and Instrumentation\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0955598625000767\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Flow Measurement and Instrumentation","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0955598625000767","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

智能水表在促进城市可持续发展、优化水资源管理、提高公用事业效率和减少环境影响方面发挥着至关重要的作用。关于它们在不同条件下的长期表现的知识有限。这项研究评估了家庭中的现代超声波水表,测试了来自五个品牌的六对水表。评估包括改变水流速率、模拟启动和停止、突然供应变化和耐久性评估。一般来说,仪表表现准确,避免了一致的多计或少计。然而,由于技术差异,不同品牌和车型的性能各不相同。集成电池配备的仪表满足精度标准,但在更苛刻的测试条件下表现出差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Behavior of domestic ultrasonic water meters subjected to multiple tests

Behavior of domestic ultrasonic water meters subjected to multiple tests
Smart water meters play a crucial role in promoting sustainable urban development, optimizing water management, utility efficiency, and reducing environmental impact. Limited knowledge exists regarding their long-term performance across diverse conditions. This study assessed modern ultrasonic water meters in households, testing six pairs from five brands. Evaluations involved varying water flow rates, simulating starts and stops, abrupt supply changes, and durability assessments. Generally, the meters performed accurately, avoiding consistent over- or undercounting. However, performance varied across brands and models due to technological disparities. Integrated battery-equipped meters met accuracy standards, yet exhibited discrepancies in more demanding testing conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Flow Measurement and Instrumentation
Flow Measurement and Instrumentation 工程技术-工程:机械
CiteScore
4.30
自引率
13.60%
发文量
123
审稿时长
6 months
期刊介绍: Flow Measurement and Instrumentation is dedicated to disseminating the latest research results on all aspects of flow measurement, in both closed conduits and open channels. The design of flow measurement systems involves a wide variety of multidisciplinary activities including modelling the flow sensor, the fluid flow and the sensor/fluid interactions through the use of computation techniques; the development of advanced transducer systems and their associated signal processing and the laboratory and field assessment of the overall system under ideal and disturbed conditions. FMI is the essential forum for critical information exchange, and contributions are particularly encouraged in the following areas of interest: Modelling: the application of mathematical and computational modelling to the interaction of fluid dynamics with flowmeters, including flowmeter behaviour, improved flowmeter design and installation problems. Application of CAD/CAE techniques to flowmeter modelling are eligible. Design and development: the detailed design of the flowmeter head and/or signal processing aspects of novel flowmeters. Emphasis is given to papers identifying new sensor configurations, multisensor flow measurement systems, non-intrusive flow metering techniques and the application of microelectronic techniques in smart or intelligent systems. Calibration techniques: including descriptions of new or existing calibration facilities and techniques, calibration data from different flowmeter types, and calibration intercomparison data from different laboratories. Installation effect data: dealing with the effects of non-ideal flow conditions on flowmeters. Papers combining a theoretical understanding of flowmeter behaviour with experimental work are particularly welcome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信