喷射复合阻尼环光束位置监测器的标定

IF 0.4 4区 工程技术 Q4 ENGINEERING, MULTIDISCIPLINARY
Yu. A. Rogovsky, E. A. Bekhtenev
{"title":"喷射复合阻尼环光束位置监测器的标定","authors":"Yu. A. Rogovsky,&nbsp;E. A. Bekhtenev","doi":"10.1134/S0020441224701884","DOIUrl":null,"url":null,"abstract":"<p>The calibration of two types of an electrostatic beam position monitor was carried out. Signals from the electrodes are converted into beam coordinates using a nonlinear polynomial transformation, the coefficients of which are calculated using the least squares method. This made it possible to measure the position of the beam with an accuracy better than the required value of 0.1 mm for a single passage of the beam. The mechanical center of the monitor has been linked to external geodetic signs. The calibration result was used with all monitors in the ring based on the assumption that they were all manufactured to the same mechanical accuracy. This made it possible to measure beam parameters with better accuracy than before calibration.</p>","PeriodicalId":587,"journal":{"name":"Instruments and Experimental Techniques","volume":"67 2 supplement","pages":"S242 - S249"},"PeriodicalIF":0.4000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Calibration of Beam Position Monitors for an Injection Complex Damping Ring\",\"authors\":\"Yu. A. Rogovsky,&nbsp;E. A. Bekhtenev\",\"doi\":\"10.1134/S0020441224701884\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The calibration of two types of an electrostatic beam position monitor was carried out. Signals from the electrodes are converted into beam coordinates using a nonlinear polynomial transformation, the coefficients of which are calculated using the least squares method. This made it possible to measure the position of the beam with an accuracy better than the required value of 0.1 mm for a single passage of the beam. The mechanical center of the monitor has been linked to external geodetic signs. The calibration result was used with all monitors in the ring based on the assumption that they were all manufactured to the same mechanical accuracy. This made it possible to measure beam parameters with better accuracy than before calibration.</p>\",\"PeriodicalId\":587,\"journal\":{\"name\":\"Instruments and Experimental Techniques\",\"volume\":\"67 2 supplement\",\"pages\":\"S242 - S249\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2025-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Instruments and Experimental Techniques\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S0020441224701884\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments and Experimental Techniques","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S0020441224701884","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

对两种类型的静电光束位置监测仪进行了标定。利用非线性多项式变换将电极信号转换成波束坐标,利用最小二乘法计算波束坐标系数。这使得测量光束位置的精度优于光束单通道所需的0.1毫米的精度成为可能。监视器的机械中心已连接到外部大地测量标志。校准结果与环中的所有监视器一起使用,假设它们都以相同的机械精度制造。这使得测量光束参数的精度比校准前更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Calibration of Beam Position Monitors for an Injection Complex Damping Ring

Calibration of Beam Position Monitors for an Injection Complex Damping Ring

The calibration of two types of an electrostatic beam position monitor was carried out. Signals from the electrodes are converted into beam coordinates using a nonlinear polynomial transformation, the coefficients of which are calculated using the least squares method. This made it possible to measure the position of the beam with an accuracy better than the required value of 0.1 mm for a single passage of the beam. The mechanical center of the monitor has been linked to external geodetic signs. The calibration result was used with all monitors in the ring based on the assumption that they were all manufactured to the same mechanical accuracy. This made it possible to measure beam parameters with better accuracy than before calibration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Instruments and Experimental Techniques
Instruments and Experimental Techniques 工程技术-工程:综合
CiteScore
1.20
自引率
33.30%
发文量
113
审稿时长
4-8 weeks
期刊介绍: Instruments and Experimental Techniques is an international peer reviewed journal that publishes reviews describing advanced methods for physical measurements and techniques and original articles that present techniques for physical measurements, principles of operation, design, methods of application, and analysis of the operation of physical instruments used in all fields of experimental physics and when conducting measurements using physical methods and instruments in astronomy, natural sciences, chemistry, biology, medicine, and ecology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信