{"title":"双侧矢状面劈裂截骨术后三维立体摄影测量面部肿胀的有效性和反应性——一项前瞻性临床研究。","authors":"Margje B Buitenhuis, Reinoud J Klijn, Antoine J W P Rosenberg, Caroline M Speksnijder","doi":"10.1155/ijbi/9957797","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> This study is aimed at determining the validity and responsiveness of three-dimensional (3D) stereophotogrammetry as a measurement instrument for evaluating soft tissue changes in the head and neck area. <b>Method:</b> Twelve patients received a bilateral sagittal split osteotomy (BSSO). 3D stereophotogrammetry, tape measurements, and a global perceived effect scale were performed within the first, second, and third postoperative weeks and at 3 months postoperatively. Distance measurements, mean and root mean square of the distance map, and volume differences were obtained from 3D stereophotogrammetry. Validity and responsiveness were assessed by correlation coefficients. <b>Results:</b> Significant correlations between distances from 3D stereophotogrammetry and tape measurements varied from 0.583 to 0.988, meaning moderate to very high validity. The highest correlations were found for the total sum of distances (<i>r</i> ≥ 0.922). 3D stereophotogrammetry parameters presented weak to high responsiveness, depending on the evaluated head and neck region. None of the parameters for 3D stereophotogrammetry significantly correlated with the global perceived effect scale outcomes for all measurement moments. <b>Conclusion:</b> 3D stereophotogrammetry has high to very high construct validity for the total sum of distances and weak to high responsiveness. 3D stereophotogrammetry seems promising for measuring soft tissue changes after surgery but is not interchangeable with subjective measurements.</p>","PeriodicalId":47063,"journal":{"name":"International Journal of Biomedical Imaging","volume":"2025 ","pages":"9957797"},"PeriodicalIF":3.3000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11876518/pdf/","citationCount":"0","resultStr":"{\"title\":\"Validity and Responsiveness of Measuring Facial Swelling With 3D Stereophotogrammetry in Patients After Bilateral Sagittal Split Osteotomy-A Prospective Clinimetric Study.\",\"authors\":\"Margje B Buitenhuis, Reinoud J Klijn, Antoine J W P Rosenberg, Caroline M Speksnijder\",\"doi\":\"10.1155/ijbi/9957797\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> This study is aimed at determining the validity and responsiveness of three-dimensional (3D) stereophotogrammetry as a measurement instrument for evaluating soft tissue changes in the head and neck area. <b>Method:</b> Twelve patients received a bilateral sagittal split osteotomy (BSSO). 3D stereophotogrammetry, tape measurements, and a global perceived effect scale were performed within the first, second, and third postoperative weeks and at 3 months postoperatively. Distance measurements, mean and root mean square of the distance map, and volume differences were obtained from 3D stereophotogrammetry. Validity and responsiveness were assessed by correlation coefficients. <b>Results:</b> Significant correlations between distances from 3D stereophotogrammetry and tape measurements varied from 0.583 to 0.988, meaning moderate to very high validity. The highest correlations were found for the total sum of distances (<i>r</i> ≥ 0.922). 3D stereophotogrammetry parameters presented weak to high responsiveness, depending on the evaluated head and neck region. None of the parameters for 3D stereophotogrammetry significantly correlated with the global perceived effect scale outcomes for all measurement moments. <b>Conclusion:</b> 3D stereophotogrammetry has high to very high construct validity for the total sum of distances and weak to high responsiveness. 3D stereophotogrammetry seems promising for measuring soft tissue changes after surgery but is not interchangeable with subjective measurements.</p>\",\"PeriodicalId\":47063,\"journal\":{\"name\":\"International Journal of Biomedical Imaging\",\"volume\":\"2025 \",\"pages\":\"9957797\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-02-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11876518/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Biomedical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/ijbi/9957797\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biomedical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/ijbi/9957797","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在确定三维立体摄影测量作为评估头颈部软组织变化的测量工具的有效性和响应性。方法:12例患者行双侧矢状面劈开截骨术。在术后第一、二、三周和术后3个月进行三维立体摄影测量、胶带测量和整体感知效应量表。三维立体摄影测量得到距离测量值、距离图的均方根和均方根以及体差。以相关系数评估效度和反应性。结果:三维立体摄影测量距离和纸带测量距离之间的显著相关性从0.583到0.988不等,这意味着中等到非常高的效度。总距离的相关性最高(r≥0.922)。三维立体摄影测量参数表现出弱到高的响应性,取决于评估的头颈部区域。3D立体摄影测量的参数与所有测量时刻的整体感知效应量表结果均无显著相关。结论:三维立体摄影测量在总距离上具有高到极高的构念效度,在反应性上具有弱到高的构念效度。三维立体摄影测量术似乎有希望测量手术后软组织的变化,但不能与主观测量互换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validity and Responsiveness of Measuring Facial Swelling With 3D Stereophotogrammetry in Patients After Bilateral Sagittal Split Osteotomy-A Prospective Clinimetric Study.

Introduction: This study is aimed at determining the validity and responsiveness of three-dimensional (3D) stereophotogrammetry as a measurement instrument for evaluating soft tissue changes in the head and neck area. Method: Twelve patients received a bilateral sagittal split osteotomy (BSSO). 3D stereophotogrammetry, tape measurements, and a global perceived effect scale were performed within the first, second, and third postoperative weeks and at 3 months postoperatively. Distance measurements, mean and root mean square of the distance map, and volume differences were obtained from 3D stereophotogrammetry. Validity and responsiveness were assessed by correlation coefficients. Results: Significant correlations between distances from 3D stereophotogrammetry and tape measurements varied from 0.583 to 0.988, meaning moderate to very high validity. The highest correlations were found for the total sum of distances (r ≥ 0.922). 3D stereophotogrammetry parameters presented weak to high responsiveness, depending on the evaluated head and neck region. None of the parameters for 3D stereophotogrammetry significantly correlated with the global perceived effect scale outcomes for all measurement moments. Conclusion: 3D stereophotogrammetry has high to very high construct validity for the total sum of distances and weak to high responsiveness. 3D stereophotogrammetry seems promising for measuring soft tissue changes after surgery but is not interchangeable with subjective measurements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
12.00
自引率
0.00%
发文量
11
审稿时长
20 weeks
期刊介绍: The International Journal of Biomedical Imaging is managed by a board of editors comprising internationally renowned active researchers. The journal is freely accessible online and also offered for purchase in print format. It employs a web-based review system to ensure swift turnaround times while maintaining high standards. In addition to regular issues, special issues are organized by guest editors. The subject areas covered include (but are not limited to): Digital radiography and tomosynthesis X-ray computed tomography (CT) Magnetic resonance imaging (MRI) Single photon emission computed tomography (SPECT) Positron emission tomography (PET) Ultrasound imaging Diffuse optical tomography, coherence, fluorescence, bioluminescence tomography, impedance tomography Neutron imaging for biomedical applications Magnetic and optical spectroscopy, and optical biopsy Optical, electron, scanning tunneling/atomic force microscopy Small animal imaging Functional, cellular, and molecular imaging Imaging assays for screening and molecular analysis Microarray image analysis and bioinformatics Emerging biomedical imaging techniques Imaging modality fusion Biomedical imaging instrumentation Biomedical image processing, pattern recognition, and analysis Biomedical image visualization, compression, transmission, and storage Imaging and modeling related to systems biology and systems biomedicine Applied mathematics, applied physics, and chemistry related to biomedical imaging Grid-enabling technology for biomedical imaging and informatics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信