{"title":"基于可变速率丸跟踪技术和第三代双源CT双能扫描的头颈部血管CT血管造影优化","authors":"Wei-Hua Lin, Fei-Peng Zhang, Bing-Quan Wang, Rui-Gang Huang, A-Lai Zhan, Hui-Jun Xiao","doi":"10.1186/s12880-025-01613-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the effectiveness of the variable rate bolus tracking technique combined with third-generation dual-source CT dual-energy scanning in enhancing the quality of head and neck vascular CT angiography (CTA).</p><p><strong>Methods: </strong>We conducted a retrospective analysis of 202 patients who underwent head and neck vascular CTA using a third-generation dual-source CT with dual-energy scanning. Patients were divided based on the contrast injection method into two groups: the variable-rate bolus tracking group (Group A, n = 100) and the fixed flow rate group (Group B, n = 102). We compared subjective image quality, venous artifacts, and objective image quality parameters between the two groups.</p><p><strong>Results: </strong>The amount of contrast agent used in Group A was significantly lower than in Group B. Additionally, mean attenuation values of arterial segments in Group A were markedly lower than those in Group B. Compared to Group B, attenuation values of the intracranial venous sinuses, right jugular vein, superior vena cava, right subclavian vein, and left jugular vein in Group A showed significant reductions. No significant difference was observed in the subjective image quality between the two groups. However, venous artifact in the right subclavian vein was significantly diminished in Group A.</p><p><strong>Conclusion: </strong>The application of the variable rate bolus tracking technique alongside third-generation dual-source CT dual-energy scanning in head and neck vascular CTA can achieve high-quality imaging while reducing contrast agent dosage. It enhances the attenuation contrast of intracranial arteries and veins and minimizes residual contrast and artifacts in the right subclavian vein.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"25 1","pages":"72"},"PeriodicalIF":2.9000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11877775/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optimization of head and neck vascular CT angiography using variable rate bolus tracking technique and third-generation dual-source CT dual-energy scanning.\",\"authors\":\"Wei-Hua Lin, Fei-Peng Zhang, Bing-Quan Wang, Rui-Gang Huang, A-Lai Zhan, Hui-Jun Xiao\",\"doi\":\"10.1186/s12880-025-01613-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate the effectiveness of the variable rate bolus tracking technique combined with third-generation dual-source CT dual-energy scanning in enhancing the quality of head and neck vascular CT angiography (CTA).</p><p><strong>Methods: </strong>We conducted a retrospective analysis of 202 patients who underwent head and neck vascular CTA using a third-generation dual-source CT with dual-energy scanning. Patients were divided based on the contrast injection method into two groups: the variable-rate bolus tracking group (Group A, n = 100) and the fixed flow rate group (Group B, n = 102). We compared subjective image quality, venous artifacts, and objective image quality parameters between the two groups.</p><p><strong>Results: </strong>The amount of contrast agent used in Group A was significantly lower than in Group B. Additionally, mean attenuation values of arterial segments in Group A were markedly lower than those in Group B. Compared to Group B, attenuation values of the intracranial venous sinuses, right jugular vein, superior vena cava, right subclavian vein, and left jugular vein in Group A showed significant reductions. No significant difference was observed in the subjective image quality between the two groups. However, venous artifact in the right subclavian vein was significantly diminished in Group A.</p><p><strong>Conclusion: </strong>The application of the variable rate bolus tracking technique alongside third-generation dual-source CT dual-energy scanning in head and neck vascular CTA can achieve high-quality imaging while reducing contrast agent dosage. It enhances the attenuation contrast of intracranial arteries and veins and minimizes residual contrast and artifacts in the right subclavian vein.</p>\",\"PeriodicalId\":9020,\"journal\":{\"name\":\"BMC Medical Imaging\",\"volume\":\"25 1\",\"pages\":\"72\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11877775/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Medical Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12880-025-01613-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-025-01613-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价可变速率丸跟踪技术结合第三代双源CT双能扫描提高头颈部血管CT血管造影(CTA)质量的效果。方法:我们对202例使用第三代双源CT双能扫描行头颈部血管CTA的患者进行回顾性分析。根据注射对比剂的方法将患者分为两组:可变流速丸跟踪组(A组,n = 100)和固定流速组(B组,n = 102)。我们比较了两组的主观图像质量、静脉伪影和客观图像质量参数。结果:A组造影剂用量明显低于B组,A组动脉段平均衰减值明显低于B组。与B组相比,A组颅内静脉窦、右颈静脉、上腔静脉、右锁骨下静脉、左颈静脉衰减值均明显降低。两组患者主观图像质量无明显差异。结论:在头颈部血管CTA中应用可变速率丸跟踪技术配合第三代双源CT双能扫描,可以在减少造影剂用量的同时获得高质量的成像。增强颅内动静脉的衰减造影剂,减少右侧锁骨下静脉的残留造影剂和伪影。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimization of head and neck vascular CT angiography using variable rate bolus tracking technique and third-generation dual-source CT dual-energy scanning.

Objective: To evaluate the effectiveness of the variable rate bolus tracking technique combined with third-generation dual-source CT dual-energy scanning in enhancing the quality of head and neck vascular CT angiography (CTA).

Methods: We conducted a retrospective analysis of 202 patients who underwent head and neck vascular CTA using a third-generation dual-source CT with dual-energy scanning. Patients were divided based on the contrast injection method into two groups: the variable-rate bolus tracking group (Group A, n = 100) and the fixed flow rate group (Group B, n = 102). We compared subjective image quality, venous artifacts, and objective image quality parameters between the two groups.

Results: The amount of contrast agent used in Group A was significantly lower than in Group B. Additionally, mean attenuation values of arterial segments in Group A were markedly lower than those in Group B. Compared to Group B, attenuation values of the intracranial venous sinuses, right jugular vein, superior vena cava, right subclavian vein, and left jugular vein in Group A showed significant reductions. No significant difference was observed in the subjective image quality between the two groups. However, venous artifact in the right subclavian vein was significantly diminished in Group A.

Conclusion: The application of the variable rate bolus tracking technique alongside third-generation dual-source CT dual-energy scanning in head and neck vascular CTA can achieve high-quality imaging while reducing contrast agent dosage. It enhances the attenuation contrast of intracranial arteries and veins and minimizes residual contrast and artifacts in the right subclavian vein.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信