衰减成像的空间加权保真度和正则化项。

IF 3 2区 工程技术 Q1 ACOUSTICS
Sebastian Merino;Roberto Lavarello
{"title":"衰减成像的空间加权保真度和正则化项。","authors":"Sebastian Merino;Roberto Lavarello","doi":"10.1109/TUFFC.2025.3534660","DOIUrl":null,"url":null,"abstract":"Quantitative ultrasound (QUS) holds promise in enhancing diagnostic accuracy. For attenuation imaging, the regularized spectral log difference (RSLD) can generate accurate local attenuation maps. However, the performance of the method degrades when significant changes in backscatter amplitude occur. Variations in the technique were introduced involving a weighted approach to backscatter regularization, which, however, is not effective when changes in both attenuation and backscatter are present. This study introduces a novel approach that incorporates an L1-norm for backscatter regularization and spatially varying weights for both fidelity and regularization terms. The weights are calculated from an initial estimation of backscatter changes. Comparative analyses with simulated, phantom, and clinical data were performed. When changes in backscatter and attenuation occur, the proposed approach reduced the lowest root mean square error by up to 73%. It also improved the contrast-to-noise ratio (CNR) by a factor of 4.4 on average compared with previously available methods, considering the simulated and phantom data. In vivo results from healthy livers, thyroid nodules, and a breast tumor further confirm its effectiveness. In the liver, it is shown to be effective at reducing artifacts of attenuation images. In thyroid and breast tumors, the method demonstrated an enhanced CNR and better consistency of the attenuation measurements with the posterior acoustic enhancement. Overall, this approach offers promise for enhancing ultrasound attenuation imaging by helping differentiate tissue characteristics that may indicate pathology.","PeriodicalId":13322,"journal":{"name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","volume":"72 3","pages":"338-350"},"PeriodicalIF":3.0000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Spatially Weighted Fidelity and Regularization Terms for Attenuation Imaging\",\"authors\":\"Sebastian Merino;Roberto Lavarello\",\"doi\":\"10.1109/TUFFC.2025.3534660\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Quantitative ultrasound (QUS) holds promise in enhancing diagnostic accuracy. For attenuation imaging, the regularized spectral log difference (RSLD) can generate accurate local attenuation maps. However, the performance of the method degrades when significant changes in backscatter amplitude occur. Variations in the technique were introduced involving a weighted approach to backscatter regularization, which, however, is not effective when changes in both attenuation and backscatter are present. This study introduces a novel approach that incorporates an L1-norm for backscatter regularization and spatially varying weights for both fidelity and regularization terms. The weights are calculated from an initial estimation of backscatter changes. Comparative analyses with simulated, phantom, and clinical data were performed. When changes in backscatter and attenuation occur, the proposed approach reduced the lowest root mean square error by up to 73%. It also improved the contrast-to-noise ratio (CNR) by a factor of 4.4 on average compared with previously available methods, considering the simulated and phantom data. In vivo results from healthy livers, thyroid nodules, and a breast tumor further confirm its effectiveness. In the liver, it is shown to be effective at reducing artifacts of attenuation images. In thyroid and breast tumors, the method demonstrated an enhanced CNR and better consistency of the attenuation measurements with the posterior acoustic enhancement. Overall, this approach offers promise for enhancing ultrasound attenuation imaging by helping differentiate tissue characteristics that may indicate pathology.\",\"PeriodicalId\":13322,\"journal\":{\"name\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"volume\":\"72 3\",\"pages\":\"338-350\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-01-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10854993/\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10854993/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

定量超声有望提高诊断的准确性。对于衰减成像,正则化的谱对数差可以生成精确的局部衰减图。然而,当后向散射幅度发生显著变化时,该方法的性能会下降。引入了涉及加权后向散射正则化的技术变体,然而,当衰减和后向散射同时存在变化时,该方法无效。本研究引入了一种新的方法,该方法结合了l1范数用于后向散射正则化,以及保真度和正则化项的空间变化权重。权重是通过对后向散射变化的初始估计来计算的。与模拟、模拟和临床数据进行比较分析。当后向散射和衰减发生变化时,该方法可将最小均方根误差降低高达73%。考虑到模拟数据和模拟数据,与之前可用的方法相比,它还将噪比平均提高了4.4倍。健康肝脏、甲状腺结节和乳腺肿瘤的体内实验结果进一步证实了其有效性。在肝脏中,它被证明可以有效地减少衰减图像的伪影。在甲状腺和乳腺肿瘤中,该方法显示出增强的对比噪声比和衰减测量与后路声增强的更好一致性。总的来说,这种方法通过帮助区分可能指示病理的组织特征,为增强超声衰减成像提供了希望。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Spatially Weighted Fidelity and Regularization Terms for Attenuation Imaging
Quantitative ultrasound (QUS) holds promise in enhancing diagnostic accuracy. For attenuation imaging, the regularized spectral log difference (RSLD) can generate accurate local attenuation maps. However, the performance of the method degrades when significant changes in backscatter amplitude occur. Variations in the technique were introduced involving a weighted approach to backscatter regularization, which, however, is not effective when changes in both attenuation and backscatter are present. This study introduces a novel approach that incorporates an L1-norm for backscatter regularization and spatially varying weights for both fidelity and regularization terms. The weights are calculated from an initial estimation of backscatter changes. Comparative analyses with simulated, phantom, and clinical data were performed. When changes in backscatter and attenuation occur, the proposed approach reduced the lowest root mean square error by up to 73%. It also improved the contrast-to-noise ratio (CNR) by a factor of 4.4 on average compared with previously available methods, considering the simulated and phantom data. In vivo results from healthy livers, thyroid nodules, and a breast tumor further confirm its effectiveness. In the liver, it is shown to be effective at reducing artifacts of attenuation images. In thyroid and breast tumors, the method demonstrated an enhanced CNR and better consistency of the attenuation measurements with the posterior acoustic enhancement. Overall, this approach offers promise for enhancing ultrasound attenuation imaging by helping differentiate tissue characteristics that may indicate pathology.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.70
自引率
16.70%
发文量
583
审稿时长
4.5 months
期刊介绍: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control includes the theory, technology, materials, and applications relating to: (1) the generation, transmission, and detection of ultrasonic waves and related phenomena; (2) medical ultrasound, including hyperthermia, bioeffects, tissue characterization and imaging; (3) ferroelectric, piezoelectric, and piezomagnetic materials, including crystals, polycrystalline solids, films, polymers, and composites; (4) frequency control, timing and time distribution, including crystal oscillators and other means of classical frequency control, and atomic, molecular and laser frequency control standards. Areas of interest range from fundamental studies to the design and/or applications of devices and systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信