{"title":"漂白剂对正畸热塑性固位体材料抗压强度的影响。","authors":"Ailin Ehteshami, Saina Omidi, Maede Ghasemi","doi":"10.4103/drj.drj_216_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There is an increasing desire for teeth bleching after orthodontic treatment. Therefor, this study aims to evaluate the effect of carbamide peroxide 15% and thermocycling on the compressive strength of polyethylene terephthalate glycol (PETG) thermoplastic retainer material.</p><p><strong>Materials and methods: </strong>In this <i>in vitro</i> study, forty samples of PETG material were thermoformed over a plastic template (10 mm × 8 mm × 2 mm). The samples were divided into four groups, with ten samples in each group. Group I served as the control, Group II was exposed to carbamide peroxide 15% (5 h daily for 14 days), Group III underwent thermocycling (5000 times), and Group IV underwent thermocycling (5000 times) followed by exposure to carbamide peroxide 15% (5 h daily for 14 days). The compressive strength of the groups was then evaluated using one-way ANOVA and Tukey's HSD tests for statistical analysis. The significance level was set to 0.05.</p><p><strong>Results: </strong>The analysis showed a significant difference among the four groups. The compressive strength of all groups significantly decreased compared to the control group. Group II exhibited a significant decrease compared to Group III (<i>P</i> = 0.003). However, there was no significant difference between Group II and Group IV (<i>P</i> = 0.191). In addition, there was no significant difference observed between Group III and Group IV (<i>P</i> = 0.308). Group II had the lowest compressive strength (163.9 Mpa).</p><p><strong>Conclusion: </strong>It is not recommended to use a thermoplastic retainer as a bleaching tray during the initial phase of retention. However, since there were no further harmful effects of bleaching agents observed after thermocycling, it is possible to recommend the use of a thermoplastic retainer as a bleaching tray toward the end of the retention phase.</p>","PeriodicalId":11016,"journal":{"name":"Dental Research Journal","volume":"22 ","pages":"2"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11870327/pdf/","citationCount":"0","resultStr":"{\"title\":\"The effect of bleaching agent on the compressive strength of orthodontic thermoplastic retainer materials.\",\"authors\":\"Ailin Ehteshami, Saina Omidi, Maede Ghasemi\",\"doi\":\"10.4103/drj.drj_216_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>There is an increasing desire for teeth bleching after orthodontic treatment. Therefor, this study aims to evaluate the effect of carbamide peroxide 15% and thermocycling on the compressive strength of polyethylene terephthalate glycol (PETG) thermoplastic retainer material.</p><p><strong>Materials and methods: </strong>In this <i>in vitro</i> study, forty samples of PETG material were thermoformed over a plastic template (10 mm × 8 mm × 2 mm). The samples were divided into four groups, with ten samples in each group. Group I served as the control, Group II was exposed to carbamide peroxide 15% (5 h daily for 14 days), Group III underwent thermocycling (5000 times), and Group IV underwent thermocycling (5000 times) followed by exposure to carbamide peroxide 15% (5 h daily for 14 days). The compressive strength of the groups was then evaluated using one-way ANOVA and Tukey's HSD tests for statistical analysis. The significance level was set to 0.05.</p><p><strong>Results: </strong>The analysis showed a significant difference among the four groups. The compressive strength of all groups significantly decreased compared to the control group. Group II exhibited a significant decrease compared to Group III (<i>P</i> = 0.003). However, there was no significant difference between Group II and Group IV (<i>P</i> = 0.191). In addition, there was no significant difference observed between Group III and Group IV (<i>P</i> = 0.308). Group II had the lowest compressive strength (163.9 Mpa).</p><p><strong>Conclusion: </strong>It is not recommended to use a thermoplastic retainer as a bleaching tray during the initial phase of retention. However, since there were no further harmful effects of bleaching agents observed after thermocycling, it is possible to recommend the use of a thermoplastic retainer as a bleaching tray toward the end of the retention phase.</p>\",\"PeriodicalId\":11016,\"journal\":{\"name\":\"Dental Research Journal\",\"volume\":\"22 \",\"pages\":\"2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11870327/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Research Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/drj.drj_216_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/drj.drj_216_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

背景:正牙治疗后牙齿漂白的需求日益增加。因此,本研究旨在评价过氧化脲15%和热循环对聚对苯二甲酸乙二醇酯(PETG)热塑性固位材料抗压强度的影响。材料和方法:在体外研究中,40个PETG材料样品在塑料模板(10 mm × 8 mm × 2 mm)上热成型。样本被分为四组,每组10个样本。ⅰ组为对照组,ⅱ组为过氧化脲15%处理(每天5 h,连续14天),ⅲ组为热循环处理(5000次),ⅳ组为热循环处理(5000次),然后过氧化脲15%处理(每天5 h,连续14天)。然后使用单因素方差分析和Tukey的HSD检验进行统计分析,评估各组的抗压强度。显著性水平设为0.05。结果:分析结果显示,四组间差异有统计学意义。与对照组相比,各组抗压强度均显著降低。II组较III组有显著性降低(P = 0.003)。II组与IV组间无显著性差异(P = 0.191)。此外,III组与IV组之间无显著差异(P = 0.308)。第二组的抗压强度最低,为163.9 Mpa。结论:不建议在固位初期使用热塑性固位器作为漂白托盘。然而,由于在热循环后没有观察到漂白剂的进一步有害影响,因此有可能建议在保持阶段结束时使用热塑性保持器作为漂白托盘。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The effect of bleaching agent on the compressive strength of orthodontic thermoplastic retainer materials.

Background: There is an increasing desire for teeth bleching after orthodontic treatment. Therefor, this study aims to evaluate the effect of carbamide peroxide 15% and thermocycling on the compressive strength of polyethylene terephthalate glycol (PETG) thermoplastic retainer material.

Materials and methods: In this in vitro study, forty samples of PETG material were thermoformed over a plastic template (10 mm × 8 mm × 2 mm). The samples were divided into four groups, with ten samples in each group. Group I served as the control, Group II was exposed to carbamide peroxide 15% (5 h daily for 14 days), Group III underwent thermocycling (5000 times), and Group IV underwent thermocycling (5000 times) followed by exposure to carbamide peroxide 15% (5 h daily for 14 days). The compressive strength of the groups was then evaluated using one-way ANOVA and Tukey's HSD tests for statistical analysis. The significance level was set to 0.05.

Results: The analysis showed a significant difference among the four groups. The compressive strength of all groups significantly decreased compared to the control group. Group II exhibited a significant decrease compared to Group III (P = 0.003). However, there was no significant difference between Group II and Group IV (P = 0.191). In addition, there was no significant difference observed between Group III and Group IV (P = 0.308). Group II had the lowest compressive strength (163.9 Mpa).

Conclusion: It is not recommended to use a thermoplastic retainer as a bleaching tray during the initial phase of retention. However, since there were no further harmful effects of bleaching agents observed after thermocycling, it is possible to recommend the use of a thermoplastic retainer as a bleaching tray toward the end of the retention phase.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dental Research Journal
Dental Research Journal Dentistry-Dentistry (all)
CiteScore
1.70
自引率
0.00%
发文量
70
审稿时长
52 weeks
期刊介绍: Dental Research Journal, a publication of Isfahan University of Medical Sciences, is a peer-reviewed online journal with Bimonthly print on demand compilation of issues published. The journal’s full text is available online at http://www.drjjournal.net. The journal allows free access (Open Access) to its contents and permits authors to self-archive final accepted version of the articles on any OAI-compliant institutional / subject-based repository. The journal will cover technical and clinical studies related to health, ethical and social issues in field of Dentistry. Articles with clinical interest and implications will be given preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信