新生儿和婴儿血液中帕雷奇病毒 RT-PCR 检测:与肠道病毒感染的临床和生物学特征比较。

IF 2.9 4区 医学 Q3 IMMUNOLOGY
Christine Archimbaud, Marie-Aliette Dommergues, Jeremy Lafolie, Bruno Pereira, Matthieu Verdan, Marie Noelle Adam, Fouad Madhi, Anne-Sophie L'Honneur, Audrey Mirand, Jean-Luc Bailly, Cécile Henquell, Stéphanie Marque-Juillet
{"title":"新生儿和婴儿血液中帕雷奇病毒 RT-PCR 检测:与肠道病毒感染的临床和生物学特征比较。","authors":"Christine Archimbaud, Marie-Aliette Dommergues, Jeremy Lafolie, Bruno Pereira, Matthieu Verdan, Marie Noelle Adam, Fouad Madhi, Anne-Sophie L'Honneur, Audrey Mirand, Jean-Luc Bailly, Cécile Henquell, Stéphanie Marque-Juillet","doi":"10.1097/INF.0000000000004772","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To assess human parechovirus (HPeV) detection by real-time polymerase chain reaction in blood with or without cerebrospinal fluid samples in neonates and infants and compare the clinical and biological characteristics of HPeV patients with those of patients with or without enterovirus (EV) infection.</p><p><strong>Methods: </strong>In all, 92 HPeV-infected patients (40 newborns and 52 infants) presenting with fever without source, sepsis-like disease or suspected meningitis were evaluated in 2 French hospitals from 2007 to 2018. The clinical and biological characteristics of HPeV patients were compared with those of 100 EV-infected patients and of 95 control patients with fever without source or sepsis-like disease.</p><p><strong>Results: </strong>HPeV was detected more frequently in blood [100% (51/51)] than in cerebrospinal fluid specimens [89% (67/75), P = 0.02]. Genotyping identified HPeV3 in 76/85 (89%) positive specimens. HPeV-infected patients were more likely than EV-infected or control patients to have sepsis-like disease and required more frequent vascular filling (39% in newborns and 26% in infants) and empirical antibiotics (91% in newborns and 69% in infants). HPeV patients had lower peripheral white blood cell counts and lower lymphocyte levels ( P = 0.002) and longer lengths of hospital stay than EV or control patients ( P = 0.03). A white blood cell count <7×10 9 /L can be helpful in differentiating HPeV patients from control patients.</p><p><strong>Conclusions: </strong>Detection of HPeV should be part of the differential diagnosis of EV infections. The use of small automata to perform real-time polymerase chain reaction assays in emergency units should allow faster diagnosis and, if the result is positive, avoid prolonged length of hospital stay and unnecessary administration of antibiotics in patients without virus-bacteria co-infection.</p>","PeriodicalId":19858,"journal":{"name":"Pediatric Infectious Disease Journal","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2025-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Blood Parechovirus RT-PCR Testing in Neonates and Infants: Comparison of Clinical and Biologic Features With Those of Enterovirus Infections.\",\"authors\":\"Christine Archimbaud, Marie-Aliette Dommergues, Jeremy Lafolie, Bruno Pereira, Matthieu Verdan, Marie Noelle Adam, Fouad Madhi, Anne-Sophie L'Honneur, Audrey Mirand, Jean-Luc Bailly, Cécile Henquell, Stéphanie Marque-Juillet\",\"doi\":\"10.1097/INF.0000000000004772\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To assess human parechovirus (HPeV) detection by real-time polymerase chain reaction in blood with or without cerebrospinal fluid samples in neonates and infants and compare the clinical and biological characteristics of HPeV patients with those of patients with or without enterovirus (EV) infection.</p><p><strong>Methods: </strong>In all, 92 HPeV-infected patients (40 newborns and 52 infants) presenting with fever without source, sepsis-like disease or suspected meningitis were evaluated in 2 French hospitals from 2007 to 2018. The clinical and biological characteristics of HPeV patients were compared with those of 100 EV-infected patients and of 95 control patients with fever without source or sepsis-like disease.</p><p><strong>Results: </strong>HPeV was detected more frequently in blood [100% (51/51)] than in cerebrospinal fluid specimens [89% (67/75), P = 0.02]. Genotyping identified HPeV3 in 76/85 (89%) positive specimens. HPeV-infected patients were more likely than EV-infected or control patients to have sepsis-like disease and required more frequent vascular filling (39% in newborns and 26% in infants) and empirical antibiotics (91% in newborns and 69% in infants). HPeV patients had lower peripheral white blood cell counts and lower lymphocyte levels ( P = 0.002) and longer lengths of hospital stay than EV or control patients ( P = 0.03). A white blood cell count <7×10 9 /L can be helpful in differentiating HPeV patients from control patients.</p><p><strong>Conclusions: </strong>Detection of HPeV should be part of the differential diagnosis of EV infections. The use of small automata to perform real-time polymerase chain reaction assays in emergency units should allow faster diagnosis and, if the result is positive, avoid prolonged length of hospital stay and unnecessary administration of antibiotics in patients without virus-bacteria co-infection.</p>\",\"PeriodicalId\":19858,\"journal\":{\"name\":\"Pediatric Infectious Disease Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric Infectious Disease Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/INF.0000000000004772\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"IMMUNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Infectious Disease Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/INF.0000000000004772","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Blood Parechovirus RT-PCR Testing in Neonates and Infants: Comparison of Clinical and Biologic Features With Those of Enterovirus Infections.

Background: To assess human parechovirus (HPeV) detection by real-time polymerase chain reaction in blood with or without cerebrospinal fluid samples in neonates and infants and compare the clinical and biological characteristics of HPeV patients with those of patients with or without enterovirus (EV) infection.

Methods: In all, 92 HPeV-infected patients (40 newborns and 52 infants) presenting with fever without source, sepsis-like disease or suspected meningitis were evaluated in 2 French hospitals from 2007 to 2018. The clinical and biological characteristics of HPeV patients were compared with those of 100 EV-infected patients and of 95 control patients with fever without source or sepsis-like disease.

Results: HPeV was detected more frequently in blood [100% (51/51)] than in cerebrospinal fluid specimens [89% (67/75), P = 0.02]. Genotyping identified HPeV3 in 76/85 (89%) positive specimens. HPeV-infected patients were more likely than EV-infected or control patients to have sepsis-like disease and required more frequent vascular filling (39% in newborns and 26% in infants) and empirical antibiotics (91% in newborns and 69% in infants). HPeV patients had lower peripheral white blood cell counts and lower lymphocyte levels ( P = 0.002) and longer lengths of hospital stay than EV or control patients ( P = 0.03). A white blood cell count <7×10 9 /L can be helpful in differentiating HPeV patients from control patients.

Conclusions: Detection of HPeV should be part of the differential diagnosis of EV infections. The use of small automata to perform real-time polymerase chain reaction assays in emergency units should allow faster diagnosis and, if the result is positive, avoid prolonged length of hospital stay and unnecessary administration of antibiotics in patients without virus-bacteria co-infection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.30
自引率
2.80%
发文量
566
审稿时长
2-4 weeks
期刊介绍: ​​The Pediatric Infectious Disease Journal® (PIDJ) is a complete, up-to-the-minute resource on infectious diseases in children. Through a mix of original studies, informative review articles, and unique case reports, PIDJ delivers the latest insights on combating disease in children — from state-of-the-art diagnostic techniques to the most effective drug therapies and other treatment protocols. It is a resource that can improve patient care and stimulate your personal research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信