多色辐射条件下的断层扫描实验建模问题

IF 0.5 Q4 PHYSICS, CONDENSED MATTER
M. V. Grigoriev, Yu. S. Krivonosov, D. A. Zolotov, A. V. Buzmakov, V. E. Asadchikov
{"title":"多色辐射条件下的断层扫描实验建模问题","authors":"M. V. Grigoriev,&nbsp;Yu. S. Krivonosov,&nbsp;D. A. Zolotov,&nbsp;A. V. Buzmakov,&nbsp;V. E. Asadchikov","doi":"10.1134/S1027451024701660","DOIUrl":null,"url":null,"abstract":"<p>Modern tomographic studies using laboratory X-ray sources often employ the polychromatic mode due to the relatively low intensity of the radiation. This mode enhances the signal-to-noise ratio and improves the quality of the results of reconstruction. Modeling and analyzing the results of tomographic measurements with polychromatic X-ray radiation requires the consideration of additional aspects of the experiment compared to the monochromatic case. These aspects are related both to the spectral characteristics of the source and the interaction of polychromatic X-ray radiation with the sample and the detector. These aspects affect both the quantitative results of the simulation and interpretation of the reconstructed tomographic data. In this work, a simulation of a tomography experiment using silicon carbide samples and an aqueous solution of iohexol is performed. The influence of the X-ray tube radiation spectrum and the spectral sensitivity of the detector’s scintillator (charge-coupled device) made from various materials and thicknesses on the results of tomographic reconstruction is analyzed. Calculations are carried out both with and without consideration of these aspects. The results show that taking into account the spectral characteristics of the source and the peculiarities of the interaction between polychromatic radiation, the sample, and the detector improves the accuracy of simulating the tomography experiment.</p>","PeriodicalId":671,"journal":{"name":"Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques","volume":"18 6","pages":"1645 - 1655"},"PeriodicalIF":0.5000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Aspects of Modeling a Tomography Experiment under Conditions of Polychromatic Radiation\",\"authors\":\"M. V. Grigoriev,&nbsp;Yu. S. Krivonosov,&nbsp;D. A. Zolotov,&nbsp;A. V. Buzmakov,&nbsp;V. E. Asadchikov\",\"doi\":\"10.1134/S1027451024701660\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Modern tomographic studies using laboratory X-ray sources often employ the polychromatic mode due to the relatively low intensity of the radiation. This mode enhances the signal-to-noise ratio and improves the quality of the results of reconstruction. Modeling and analyzing the results of tomographic measurements with polychromatic X-ray radiation requires the consideration of additional aspects of the experiment compared to the monochromatic case. These aspects are related both to the spectral characteristics of the source and the interaction of polychromatic X-ray radiation with the sample and the detector. These aspects affect both the quantitative results of the simulation and interpretation of the reconstructed tomographic data. In this work, a simulation of a tomography experiment using silicon carbide samples and an aqueous solution of iohexol is performed. The influence of the X-ray tube radiation spectrum and the spectral sensitivity of the detector’s scintillator (charge-coupled device) made from various materials and thicknesses on the results of tomographic reconstruction is analyzed. Calculations are carried out both with and without consideration of these aspects. The results show that taking into account the spectral characteristics of the source and the peculiarities of the interaction between polychromatic radiation, the sample, and the detector improves the accuracy of simulating the tomography experiment.</p>\",\"PeriodicalId\":671,\"journal\":{\"name\":\"Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques\",\"volume\":\"18 6\",\"pages\":\"1645 - 1655\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1027451024701660\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, CONDENSED MATTER\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1134/S1027451024701660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, CONDENSED MATTER","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。

Aspects of Modeling a Tomography Experiment under Conditions of Polychromatic Radiation

Aspects of Modeling a Tomography Experiment under Conditions of Polychromatic Radiation

Modern tomographic studies using laboratory X-ray sources often employ the polychromatic mode due to the relatively low intensity of the radiation. This mode enhances the signal-to-noise ratio and improves the quality of the results of reconstruction. Modeling and analyzing the results of tomographic measurements with polychromatic X-ray radiation requires the consideration of additional aspects of the experiment compared to the monochromatic case. These aspects are related both to the spectral characteristics of the source and the interaction of polychromatic X-ray radiation with the sample and the detector. These aspects affect both the quantitative results of the simulation and interpretation of the reconstructed tomographic data. In this work, a simulation of a tomography experiment using silicon carbide samples and an aqueous solution of iohexol is performed. The influence of the X-ray tube radiation spectrum and the spectral sensitivity of the detector’s scintillator (charge-coupled device) made from various materials and thicknesses on the results of tomographic reconstruction is analyzed. Calculations are carried out both with and without consideration of these aspects. The results show that taking into account the spectral characteristics of the source and the peculiarities of the interaction between polychromatic radiation, the sample, and the detector improves the accuracy of simulating the tomography experiment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
25.00%
发文量
144
审稿时长
3-8 weeks
期刊介绍: Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques publishes original articles on the topical problems of solid-state physics, materials science, experimental techniques, condensed media, nanostructures, surfaces of thin films, and phase boundaries: geometric and energetical structures of surfaces, the methods of computer simulations; physical and chemical properties and their changes upon radiation and other treatments; the methods of studies of films and surface layers of crystals (XRD, XPS, synchrotron radiation, neutron and electron diffraction, electron microscopic, scanning tunneling microscopic, atomic force microscopic studies, and other methods that provide data on the surfaces and thin films). Articles related to the methods and technics of structure studies are the focus of the journal. The journal accepts manuscripts of regular articles and reviews in English or Russian language from authors of all countries. All manuscripts are peer-reviewed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信